HLS-MIB :: ramAddrTab8000Filter

MIB Reference — IPNetwork Monitor · Updated October 05, 2026

All MIBs › HLS-MIB › ramAddrTab8000Filter

ramAddrTab8000Filter

Module: HLS-MIB

OID (symbolic): HLS-MIB::ramAddrTab8000Filter

OID (numeric): 1.3.6.1.4.1.26.2.1.2

Node type: OBJECT-TYPE

Type: OCTET STRING

Access: read-write

Description: Setting this value causes the re-creation of the filtered subset (see the object ramAddrTab8000FilterEntry) of the RAM-resident Address Table in a HLS 80xx Bridge. The filtered subset consists of all entries which matched the filter value at the time of the last write to this object. The format of the OCTET STRING is:

1st octet: 0 - must not have Static flag set 1 - must have Static flag set 2 - don't care whether Static flag set 2nd octet: 0 - must not have Restrict flag set 1 - must have Restrict flag set 2 - don't care whether Restrict flag set 3rd octet: 0 - must not have Origin flag set 1 - must have Origin flag set 2 - don't care whether Origin flag set 4th octet: 1 - Address must be on channel 0 (only) 2 - Address must be on channel 1 (only) 3 - Address must be global (channels 0 AND 1) 4 - Address must not be only on channel 0 5 - Address must not be only on channel 1 6 - Address must not be global 7 - Address can be on any channels

What is ramAddrTab8000Filter?

Writing a 4-octet filter pattern to this object rebuilds the filtered view of the RAM-resident address table (exposed via ramAddrTab8000FilterEntry), keeping only entries whose Static/Restrict/Origin flags and channel location match the pattern just written. It lets an administrator narrow down a potentially large address table to just the entries relevant to a specific question, such as all static entries on a given channel.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.26.2.1.2
snmpwalk -v2c -c public <target> HLS-MIB::ramAddrTab8000Filter

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.26.2.1.2.1
snmpget -v2c -c public <target> HLS-MIB::ramAddrTab8000Filter.1

Set instance 1 (SNMPv2c):

snmpset -v2c -c private <target> 1.3.6.1.4.1.26.2.1.2.1 s <value>

Start monitoring Hughes LAN Systems networking equipment (legacy, EOL) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the HLS-MIB::ramAddrTab8000Filter OID value, configure state conditions and alerts, and monitor any Hughes LAN Systems networking equipment (legacy, EOL) from a single console.

OID Breakdown

Upper-level ancestors (7 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.26hlsCMU-MIB
Numeric OIDNameModule
1.3.6.1.4.1.26.2hlsBridgesHLS-MIB
1.3.6.1.4.1.26.2.1ethernetBridgeHLS-MIB
1.3.6.1.4.1.26.2.1.2ramAddrTab8000FilterHLS-MIB