HIRSCHMANN-MMP4-BASICL2-MIB :: hmAgentCableTesterCableStatus

MIB Reference — IPNetwork Monitor · Updated September 14, 2026

All MIBsHIRSCHMANN-MMP4-BASICL2-MIBhmAgentCableTesterCableStatus

hmAgentCableTesterCableStatus

Module: HIRSCHMANN-MMP4-BASICL2-MIB

OID (symbolic): HIRSCHMANN-MMP4-BASICL2-MIB::hmAgentCableTesterCableStatus

OID (numeric): 1.3.6.1.4.1.248.15.1.4.3

Node type: OBJECT-TYPE

Type: INTEGER

Access: read-only

Description: Indicates the results of the Cable Test.

normal(1) - The cable is working correctly. open(2) - The cable is disconnected or there is a faulty connector. short(3) - There is an electrical short in the cable. unknown(4) - No test has been performed yet, or a test is currently in progress.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.248.15.1.4.3
snmpwalk -v2c -c public <target> HIRSCHMANN-MMP4-BASICL2-MIB::hmAgentCableTesterCableStatus

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.248.15.1.4.3.1
snmpget -v2c -c public <target> HIRSCHMANN-MMP4-BASICL2-MIB::hmAgentCableTesterCableStatus.1

Start monitoring Hirschmann MMP4 industrial Ethernet switch with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the HIRSCHMANN-MMP4-BASICL2-MIB::hmAgentCableTesterCableStatus OID value, configure state conditions and alerts, and monitor any Hirschmann MMP4 industrial Ethernet switch from a single console.

OID Breakdown

Upper-level ancestors (7 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.248hirschmannHM2-TC-MIB
Numeric OIDNameModule
1.3.6.1.4.1.248.15hmPlatform4HIRSCHMANN-MMP4-BASICL2-MIB
1.3.6.1.4.1.248.15.1hmPlatform4BasicL2HIRSCHMANN-MMP4-BASICL2-MIB
1.3.6.1.4.1.248.15.1.4hmAgentCableTesterGroupHIRSCHMANN-MMP4-BASICL2-MIB
1.3.6.1.4.1.248.15.1.4.3hmAgentCableTesterCableStatusHIRSCHMANN-MMP4-BASICL2-MIB