All MIBs › HH3C-VSAN-MIB › hh3cVsanDmRCFCnt
hh3cVsanDmRCFCnt
Module: HH3C-VSAN-MIB
OID (symbolic): HH3C-VSAN-MIB::hh3cVsanDmRCFCnt
OID (numeric): 1.3.6.1.4.1.25506.2.127.1.1.1.2.1.18
Node type: OBJECT-TYPE
Type: Counter32
Access: read-only
Description: The times that local switch has participated in a RCF (Reconfigure Fabric) process in this VSAN.
What is hh3cVsanDmRCFCnt?
This read-only counter tracks the number of times the local switch has participated in a Reconfigure Fabric (RCF) process in this VSAN. Since an RCF is disruptive and typically triggered by an overlapping domain ID list during a fabric merge or a manual hh3cVsanDmDomainRestart, admins monitor this counter to spot unexpected fabric-wide reconfigurations that could have interrupted traffic. For example, an unexplained increment in hh3cVsanDmRCFCnt overnight would prompt an admin to check logs for a fabric merge event or an accidental disruptive domain restart triggered by another operator.
Examples
Walk all instances (SNMPv2c):
snmpwalk -v2c -c public <target> 1.3.6.1.4.1.25506.2.127.1.1.1.2.1.18 snmpwalk -v2c -c public <target> HH3C-VSAN-MIB::hh3cVsanDmRCFCnt
Get a specific instance (index 1):
snmpget -v2c -c public <target> 1.3.6.1.4.1.25506.2.127.1.1.1.2.1.18.1 snmpget -v2c -c public <target> HH3C-VSAN-MIB::hh3cVsanDmRCFCnt.1
Start monitoring H3C Fibre Channel SAN switch (e.g. CN3660B/CN3360B series, VSAN fabric) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the HH3C-VSAN-MIB::hh3cVsanDmRCFCnt OID value, configure state conditions and alerts, and monitor any H3C Fibre Channel SAN switch (e.g. CN3660B/CN3360B series, VSAN fabric) from a single console.
OID Breakdown
Upper-level ancestors (8 from the standard OID tree / other modules)
| Numeric OID | Name | Module |
|---|---|---|
| 1 | iso | LANART-AGENT |
| 1.3 | org | AirPair-MIB |
| 1.3.6 | dod | AirPair-MIB |
| 1.3.6.1 | internet | AirPair-MIB |
| 1.3.6.1.4 | private | AirPair-MIB |
| 1.3.6.1.4.1 | enterprises | AirPair-MIB |
| 1.3.6.1.4.1.25506 | hh3c | HH3C-OID-MIB |
| 1.3.6.1.4.1.25506.2 | hh3cCommon | HH3C-OID-MIB |
| Numeric OID | Name | Module |
|---|---|---|
| 1.3.6.1.4.1.25506.2.127 | hh3cSan | HH3C-VSAN-MIB |
| 1.3.6.1.4.1.25506.2.127.1 | hh3cVsan | HH3C-VSAN-MIB |
| 1.3.6.1.4.1.25506.2.127.1.1 | hh3cVsanMibObjects | HH3C-VSAN-MIB |
| 1.3.6.1.4.1.25506.2.127.1.1.1 | hh3cVsanDmConfiguration | HH3C-VSAN-MIB |
| 1.3.6.1.4.1.25506.2.127.1.1.1.2 | hh3cVsanDmTable | HH3C-VSAN-MIB |
| 1.3.6.1.4.1.25506.2.127.1.1.1.2.1 | hh3cVsanDmEntry | HH3C-VSAN-MIB |
| 1.3.6.1.4.1.25506.2.127.1.1.1.2.1.18 | hh3cVsanDmRCFCnt | HH3C-VSAN-MIB |