HH3C-VSAN-MIB :: hh3cVsanDmDomainIdNotAssignedNotify

MIB Reference — IPNetwork Monitor · Updated September 14, 2026

All MIBsHH3C-VSAN-MIBhh3cVsanDmDomainIdNotAssignedNotify

hh3cVsanDmDomainIdNotAssignedNotify

Module: HH3C-VSAN-MIB

OID (symbolic): HH3C-VSAN-MIB::hh3cVsanDmDomainIdNotAssignedNotify

OID (numeric): 1.3.6.1.4.1.25506.2.127.1.1.3.0.1

Node type: NOTIFICATION-TYPE

Description: This event will be triggered if a Domain ID is not assigned or configured, then the E_ports may be isolated in the VSAN. The conditions are listed as follows:

1. If the switch has enabled the fabric configuration and a request for a configured static Domain ID is rejected or no other Domain ID is assigned, the E_ports will be isolated in the particular VSAN. 2. If the switch does not enable the fabric configuration and a Domain ID is not configured, all of its E_ports will be isolated in the particular VSAN.

The notification contains the WWN of the Switch and the index of the VSAN in which the event occurred.

Examples

Send this trap to an SNMP manager — replace <manager> with the IP or hostname of your monitoring server (SNMPv2c):

snmptrap -v2c -c public <manager> '' HH3C-VSAN-MIB::hh3cVsanDmDomainIdNotAssignedNotify
snmptrap -v2c -c public <manager> '' 1.3.6.1.4.1.25506.2.127.1.1.3.0.1

Listen for incoming traps on the manager host (-f keeps it in the foreground, -Lo prints to stdout — useful for testing):

snmptrapd -f -Lo -c /dev/null authCommunity log public

Example snmptrapd log entry:

zoo11-linux.zoo [UDP: [192.168.30.111]:61914->[192.168.30.10]:162]:
  DISMAN-EVENT-MIB::sysUpTimeInstance = Timeticks: (339380186) 39 days, 6:43:21.86
  SNMPv2-MIB::snmpTrapOID.0 = OID: HH3C-VSAN-MIB::hh3cVsanDmDomainIdNotAssignedNotify

Start monitoring H3C Fibre Channel SAN switch (e.g. CN3660B/CN3360B series, VSAN fabric) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the HH3C-VSAN-MIB::hh3cVsanDmDomainIdNotAssignedNotify OID value, configure state conditions and alerts, and monitor any H3C Fibre Channel SAN switch (e.g. CN3660B/CN3360B series, VSAN fabric) from a single console.

OID Breakdown

Upper-level ancestors (8 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.25506hh3cHH3C-OID-MIB
1.3.6.1.4.1.25506.2hh3cCommonHH3C-OID-MIB
Numeric OIDNameModule
1.3.6.1.4.1.25506.2.127hh3cSanHH3C-VSAN-MIB
1.3.6.1.4.1.25506.2.127.1hh3cVsanHH3C-VSAN-MIB
1.3.6.1.4.1.25506.2.127.1.1hh3cVsanMibObjectsHH3C-VSAN-MIB
1.3.6.1.4.1.25506.2.127.1.1.3hh3cVsanDmNotificationsHH3C-VSAN-MIB
1.3.6.1.4.1.25506.2.127.1.1.3.0hh3cVsanDmNotificationPrefixHH3C-VSAN-MIB
1.3.6.1.4.1.25506.2.127.1.1.3.0.1hh3cVsanDmDomainIdNotAssignedNotifyHH3C-VSAN-MIB