HH3C-RAID-MIB :: hh3cRaidType

MIB Reference — IPNetwork Monitor · Updated October 05, 2026

All MIBs › HH3C-RAID-MIB › hh3cRaidType

hh3cRaidType

Module: HH3C-RAID-MIB

OID (symbolic): HH3C-RAID-MIB::hh3cRaidType

OID (numeric): 1.3.6.1.4.1.25506.10.4.1.3.1.8

Node type: OBJECT-TYPE

Type: INTEGER

Access: read-write

Description: This object identifies the physical type of an array. The value 'virtualDevice' means if a array is prepared for virtual device, it can be used to create LV, for exampe, it is can be split into a lot of LV, or be a part of LV. The value 'directDevice' means if a array is prepared for direct device, it can be used to create a LV which type is direct. Unlike virtual devices, they cannot be combined or split into multiple logical devices. The value 'serviceEnabledDevice' means if a array is prepared for service-enabled device, it can be used to create a LV which type is service-enabled. Unlike virtual devices, they cannot be combined or split into multiple logical devices. The value 'unassigned' means it is the original status of a array, if a array is unassigned, it can't be used to create LV.

What is hh3cRaidType?

Classifies the array's intended usage: virtualDevice (can be split into or combined from multiple logical volumes), directDevice or serviceEnabledDevice (fixed 1:1 mapping to a single logical volume, cannot be combined/split), or unassigned (not yet usable for any logical volume) -- an admin sets this before provisioning storage from the array.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.25506.10.4.1.3.1.8
snmpwalk -v2c -c public <target> HH3C-RAID-MIB::hh3cRaidType

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.25506.10.4.1.3.1.8.1
snmpget -v2c -c public <target> HH3C-RAID-MIB::hh3cRaidType.1

Set instance 1 (SNMPv2c):

snmpset -v2c -c private <target> 1.3.6.1.4.1.25506.10.4.1.3.1.8.1 i <value>

Start monitoring H3C storage/server platform with RAID controller with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the HH3C-RAID-MIB::hh3cRaidType OID value, configure state conditions and alerts, and monitor any H3C storage/server platform with RAID controller from a single console.

OID Breakdown

Upper-level ancestors (9 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.25506hh3cHH3C-OID-MIB
1.3.6.1.4.1.25506.10hh3cStorageRefHH3C-OID-MIB
1.3.6.1.4.1.25506.10.4hh3cRaidHH3C-OID-MIB
Numeric OIDNameModule
1.3.6.1.4.1.25506.10.4.1hh3cRaidMibObjectsHH3C-RAID-MIB
1.3.6.1.4.1.25506.10.4.1.3hh3cRaidManageTableHH3C-RAID-MIB
1.3.6.1.4.1.25506.10.4.1.3.1hh3cRaidManageEntryHH3C-RAID-MIB
1.3.6.1.4.1.25506.10.4.1.3.1.8hh3cRaidTypeHH3C-RAID-MIB