HH3C-POWER-ETH-EXT-MIB :: hh3cPOEThresholdACMimimum

MIB Reference — IPNetwork Monitor · Updated September 14, 2026

All MIBsHH3C-POWER-ETH-EXT-MIBhh3cPOEThresholdACMimimum

hh3cPOEThresholdACMimimum

Module: HH3C-POWER-ETH-EXT-MIB

OID (symbolic): HH3C-POWER-ETH-EXT-MIB::hh3cPOEThresholdACMimimum

OID (numeric): 1.3.6.1.4.1.25506.2.14.8.1.1

Node type: OBJECT-TYPE

Type: OCTET STRING

Access: read-write

Description: Input threshold AC minimum. It is a read-write node. The value of this node is 'OCTET STRING', it is used to describe a float value. So this string should fit the following rule: 1. This string should be terminated by '\0'; 2. Every characters should be number or radix point; 3. The radix point should occur only once, and it should not be the first or the last character of the string. The value of this node should be smaller than 264.0V and larger than 90.0V. And it should be smaller than the hh3cPOEThresholdACMaximum.

What is hh3cPOEThresholdACMimimum?

Read-write OCTET STRING holding a null-terminated numeric string (digits plus at most one decimal point) that sets the low-voltage alarm threshold for AC input, constrained between 90.0V and 264.0V and required to stay below hh3cPOEThresholdACMaximum.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.25506.2.14.8.1.1
snmpwalk -v2c -c public <target> HH3C-POWER-ETH-EXT-MIB::hh3cPOEThresholdACMimimum

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.25506.2.14.8.1.1.1
snmpget -v2c -c public <target> HH3C-POWER-ETH-EXT-MIB::hh3cPOEThresholdACMimimum.1

Set instance 1 (SNMPv2c):

snmpset -v2c -c private <target> 1.3.6.1.4.1.25506.2.14.8.1.1.1 s <value>

Start monitoring H3C Comware Ethernet switch (extended PoE port/PSE status) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the HH3C-POWER-ETH-EXT-MIB::hh3cPOEThresholdACMimimum OID value, configure state conditions and alerts, and monitor any H3C Comware Ethernet switch (extended PoE port/PSE status) from a single console.

OID Breakdown

Upper-level ancestors (9 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.25506hh3cHH3C-OID-MIB
1.3.6.1.4.1.25506.2hh3cCommonHH3C-OID-MIB
1.3.6.1.4.1.25506.2.14hh3cPowerEthernetExtHH3C-OID-MIB
Numeric OIDNameModule
1.3.6.1.4.1.25506.2.14.8hh3cPOEPowerObjectsHH3C-POWER-ETH-EXT-MIB
1.3.6.1.4.1.25506.2.14.8.1hh3cPOEThresholdLimitObjsHH3C-POWER-ETH-EXT-MIB