HH3C-POWER-ETH-EXT-MIB :: hh3cMainPsePowerLimit

MIB Reference — IPNetwork Monitor · Updated September 14, 2026

All MIBsHH3C-POWER-ETH-EXT-MIBhh3cMainPsePowerLimit

hh3cMainPsePowerLimit

Module: HH3C-POWER-ETH-EXT-MIB

OID (symbolic): HH3C-POWER-ETH-EXT-MIB::hh3cMainPsePowerLimit

OID (numeric): 1.3.6.1.4.1.25506.2.14.2.1.1

Node type: OBJECT-TYPE

Type: Integer32

Access: read-write

Description: The object specifies the power limit set for the unit as a whole. The PoE unit will already have a nominal power defined by the IETF Power MIB [1] pethMainPsePower object. This OPTIONAL object specifies a further limit to this nominal power value. This may be useful to control the thermals of the unit, or for internal testing purposes. One possible use for this object may be to lower the power consumption of the unit if one or more of the internal fans have broken. It is a read/write integer value with units of Watts (note - Watts is chosen instead of milliWatts here since the IETF Power MIB [1] measures unit based parameters, such as the pethMainPsePower object, in units of Watts).

What is hh3cMainPsePowerLimit?

Read-write Integer32 in Watts that further caps the PSE unit's total nominal PoE power (below the IETF pethMainPsePower value), useful for controlling thermals or after an internal fan has failed.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.25506.2.14.2.1.1
snmpwalk -v2c -c public <target> HH3C-POWER-ETH-EXT-MIB::hh3cMainPsePowerLimit

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.25506.2.14.2.1.1.1
snmpget -v2c -c public <target> HH3C-POWER-ETH-EXT-MIB::hh3cMainPsePowerLimit.1

Set instance 1 (SNMPv2c):

snmpset -v2c -c private <target> 1.3.6.1.4.1.25506.2.14.2.1.1.1 i <value>

Start monitoring H3C Comware Ethernet switch (extended PoE port/PSE status) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the HH3C-POWER-ETH-EXT-MIB::hh3cMainPsePowerLimit OID value, configure state conditions and alerts, and monitor any H3C Comware Ethernet switch (extended PoE port/PSE status) from a single console.

OID Breakdown

Upper-level ancestors (9 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.25506hh3cHH3C-OID-MIB
1.3.6.1.4.1.25506.2hh3cCommonHH3C-OID-MIB
1.3.6.1.4.1.25506.2.14hh3cPowerEthernetExtHH3C-OID-MIB
Numeric OIDNameModule
1.3.6.1.4.1.25506.2.14.2hh3cMainPseTableHH3C-POWER-ETH-EXT-MIB
1.3.6.1.4.1.25506.2.14.2.1hh3cMainPseEntryHH3C-POWER-ETH-EXT-MIB
1.3.6.1.4.1.25506.2.14.2.1.1hh3cMainPsePowerLimitHH3C-POWER-ETH-EXT-MIB