HH3C-LSW-DEV-ADM-MIB :: hh3cLswSysCpuRatio

MIB Reference — IPNetwork Monitor · Updated September 14, 2026

All MIBsHH3C-LSW-DEV-ADM-MIBhh3cLswSysCpuRatio

hh3cLswSysCpuRatio

Module: HH3C-LSW-DEV-ADM-MIB

OID (symbolic): HH3C-LSW-DEV-ADM-MIB::hh3cLswSysCpuRatio

OID (numeric): 1.3.6.1.4.1.25506.8.35.18.1.3

Node type: OBJECT-TYPE

Type: Integer32

Access: read-only

Description: CPU usage of the system in accuracy of 1%, and the range of value is 1 to 100.

What is hh3cLswSysCpuRatio?

This reports the switch's overall CPU usage as a percentage (0-100), accurate to within 1%. An admin polls this to catch sustained high CPU load that could indicate a routing loop, attack traffic, or a software issue.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.25506.8.35.18.1.3
snmpwalk -v2c -c public <target> HH3C-LSW-DEV-ADM-MIB::hh3cLswSysCpuRatio

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.25506.8.35.18.1.3.1
snmpget -v2c -c public <target> HH3C-LSW-DEV-ADM-MIB::hh3cLswSysCpuRatio.1

Start monitoring H3C LSW-family Layer 2 switch (device administration/slot config) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the HH3C-LSW-DEV-ADM-MIB::hh3cLswSysCpuRatio OID value, configure state conditions and alerts, and monitor any H3C LSW-family Layer 2 switch (device administration/slot config) from a single console.

How to Use in IPNetwork Monitor

Select an H3C S5560X-EI (2022) as the target host to create a monitor — the SNMP service should be up and running on it. Click New Monitor, then check SNMP Custom on the Favorites tab, click Next, and confirm the host. On the next page, click Select... to open the built-in SNMP MIB Browser and type hh3cLswSysCpuRatio into the Find box to locate it in the OID tree, then select it and click OK. This OID reports the switch's overall CPU utilization as a percentage (0-100). On the monitor's Main parameters page you can set the target's SNMP port (default 161), credentials, polling interval, and other settings — see the SNMP Monitor help for details. On the State conditions and Alerting tabs, configure when the monitor should change state and trigger an alert; since this is an Integer32-type OID, Value bounds is the most useful condition here — trigger an alert if CPU utilization exceeds 85%, a common warning threshold before sustained high load affects switching performance. Click Finish to create the monitor; you can adjust any parameter later.

OID Breakdown

Upper-level ancestors (9 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.25506hh3cHH3C-OID-MIB
1.3.6.1.4.1.25506.8hh3cRhwHH3C-OID-MIB
1.3.6.1.4.1.25506.8.35hh3clswCommonHH3C-OID-MIB
Numeric OIDNameModule
1.3.6.1.4.1.25506.8.35.18hh3cLswDeviceAdminHH3C-LSW-DEV-ADM-MIB
1.3.6.1.4.1.25506.8.35.18.1hh3cLswSystemParaHH3C-LSW-DEV-ADM-MIB
1.3.6.1.4.1.25506.8.35.18.1.3hh3cLswSysCpuRatioHH3C-LSW-DEV-ADM-MIB