HH3C-COMMON-SYSTEM-MIB :: hh3cSysBootType

MIB Reference — IPNetwork Monitor · Updated October 02, 2026

All MIBs › HH3C-COMMON-SYSTEM-MIB › hh3cSysBootType

hh3cSysBootType

Module: HH3C-COMMON-SYSTEM-MIB

OID (symbolic): HH3C-COMMON-SYSTEM-MIB::hh3cSysBootType

OID (numeric): 1.3.6.1.4.1.25506.6.10

Node type: OBJECT-TYPE

Type: INTEGER

Access: read-only

Description: The boot type of the system whether the last device reboot was by CLI (warm start) or power off (cold start).

What is hh3cSysBootType?

This enumerated value reports whether the device's most recent restart was a warm start (triggered by CLI command) or a cold start (power cycle). Admins check it after an unexpected outage to distinguish a deliberate reload from an unplanned power loss or crash. A value of coldStart(1) after an incident points to a power interruption, while warmStart(2) confirms the reboot was operator-initiated via the command line.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.25506.6.10
snmpwalk -v2c -c public <target> HH3C-COMMON-SYSTEM-MIB::hh3cSysBootType

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.25506.6.10.1
snmpget -v2c -c public <target> HH3C-COMMON-SYSTEM-MIB::hh3cSysBootType.1

Start monitoring H3C switch/router (baseline system status/identity) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the HH3C-COMMON-SYSTEM-MIB::hh3cSysBootType OID value, configure state conditions and alerts, and monitor any H3C switch/router (baseline system status/identity) from a single console.

How to Use in IPNetwork Monitor

Select an H3C switch/router (baseline system status/identity) as the target host to create a monitor — the SNMP service should be up and running on it. Click New Monitor, then check SNMP Custom on the Favorites tab, click Next, and confirm the host. On the next page, click Select... to open the built-in SNMP MIB Browser and type hh3cSysBootType into the Find box to locate it in the OID tree, then select it and click OK. The boot type of the system whether the last device reboot was by CLI (warm start) or power off (cold start). On the monitor's Main parameters page you can set the target's SNMP port (default 161), credentials, polling interval, and other settings — see the SNMP Monitor help for details. On the State conditions and Alerting tabs, configure when the monitor should change state and trigger an alert; since this is an INTEGER-type OID, Value bounds is the most useful condition here — trigger an alert if the value is anything other than 'warmStart', since that indicates the condition this object reports has changed to one worth investigating. Click Finish to create the monitor; you can adjust any parameter later.

OID Breakdown

Upper-level ancestors (8 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.25506hh3cHH3C-OID-MIB
1.3.6.1.4.1.25506.6hh3cSystemHH3C-OID-MIB
Numeric OIDNameModule
1.3.6.1.4.1.25506.6.10hh3cSysBootTypeHH3C-COMMON-SYSTEM-MIB