HDS9900MIB :: portHostMode

MIB Reference — IPNetwork Monitor · Updated October 05, 2026

All MIBs › HDS9900MIB › portHostMode

portHostMode

Module: HDS9900MIB

OID (symbolic): HDS9900MIB::portHostMode

OID (numeric): 1.3.6.1.4.1.116.5.11.4.1.1.11.1.1.4

Node type: OBJECT-TYPE

Type: OCTET STRING

Access: read-write

Description: Host mode of the port.

Upper 4 bits. - Each bit has the meaning. Bit Mean 0 Not used. (For reservation. Always 0.) 1 Not used. (For reservation. Always 0.) 2 Not used. (For reservation. Always 0.) 3 Ultra-SCSI mode.

Lower 4 bits. - Numerical value shown by four bits. Value Mean 0 Normal setting. 1 IBM-7135 mode. 2 NCR mode. 3 Not used. (Reserved) 4 Sequent mode. 5 DEC OPEN VMS mode. 6 UNISYS-NX mode 7 UNISYS-IX mode. 8 HP mode. 9 VxVM-DMP mode. 10 Not used. (Reserved) 11 MPE mode. other Not used. (Reserved)

Note: The following value has a special meaning. Value Mean 0xFF Out of the host mode setting object.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.116.5.11.4.1.1.11.1.1.4
snmpwalk -v2c -c public <target> HDS9900MIB::portHostMode

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.116.5.11.4.1.1.11.1.1.4.1
snmpget -v2c -c public <target> HDS9900MIB::portHostMode.1

Set instance 1 (SNMPv2c):

snmpset -v2c -c private <target> 1.3.6.1.4.1.116.5.11.4.1.1.11.1.1.4.1 s <value>

Start monitoring Hitachi 9900 series (Lightning/Freedom) enterprise storage array with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the HDS9900MIB::portHostMode OID value, configure state conditions and alerts, and monitor any Hitachi 9900 series (Lightning/Freedom) enterprise storage array from a single console.

OID Breakdown

Upper-level ancestors (8 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.116hitachiHCP-MIB
1.3.6.1.4.1.116.5systemExMibHCP-MIB
Numeric OIDNameModule
1.3.6.1.4.1.116.5.11storageExMibHDS9900MIB
1.3.6.1.4.1.116.5.11.4raidExMibHDS9900MIB
1.3.6.1.4.1.116.5.11.4.1raidExMibDummyHDS9900MIB
1.3.6.1.4.1.116.5.11.4.1.1raidExMibRootHDS9900MIB
1.3.6.1.4.1.116.5.11.4.1.1.11raidExMibLUConfigurationHDS9900MIB
1.3.6.1.4.1.116.5.11.4.1.1.11.1raidExMibPortTableHDS9900MIB
1.3.6.1.4.1.116.5.11.4.1.1.11.1.1raidExMibPortEntryHDS9900MIB
1.3.6.1.4.1.116.5.11.4.1.1.11.1.1.4portHostModeHDS9900MIB