H3C-FC-ZONE-SERVER-MIB :: h3cFcZsServerLastResult

MIB Reference — IPNetwork Monitor · Updated September 14, 2026

All MIBsH3C-FC-ZONE-SERVER-MIBh3cFcZsServerLastResult

h3cFcZsServerLastResult

Module: H3C-FC-ZONE-SERVER-MIB

OID (symbolic): H3C-FC-ZONE-SERVER-MIB::h3cFcZsServerLastResult

OID (numeric): 1.3.6.1.4.1.2011.10.2.127.9.1.1.1.1.6

Node type: OBJECT-TYPE

Type: INTEGER

Access: read-only

Description: Current operational status of the latest configuration in this VSAN:

'none' - No corresponding operation has been performed yet. 'success' - The configuration was performed successfully. 'busy' - The configuration was performed unsuccessfully, because the system is busy with another zoning operation. 'noSupportInFabric' - The configuration was performed unsuccessfully, because one or more switches in this Fabric don't support Enhanced zoning. 'noSupportInBasic' - The configuration was performed unsuccessfully, because it is not supported in Basic mode. 'noSupportInEnhanced' - The configuration was performed unsuccessfully, because it is not supported in Enhanced mode. 'activeZoneSetTooBig' - The configuration was performed unsuccessfully, because the Active Zone Set is too large to be supported. 'otherFault' - The configuration was performed unsuccessfully for other reasons.

What is h3cFcZsServerLastResult?

This reports the outcome of the most recent zoning configuration operation on this VSAN's Zone Server: none(1), success(2), busy(3), noSupportInFabric(4), noSupportInBasic(5), noSupportInEnhanced(6), activeZoneSetTooBig(7), or otherFault(8). Admins check this after pushing a zoning change to confirm it actually took effect rather than silently failing, for example due to one switch in the fabric lacking Enhanced-mode support.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.2011.10.2.127.9.1.1.1.1.6
snmpwalk -v2c -c public <target> H3C-FC-ZONE-SERVER-MIB::h3cFcZsServerLastResult

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.2011.10.2.127.9.1.1.1.1.6.1
snmpget -v2c -c public <target> H3C-FC-ZONE-SERVER-MIB::h3cFcZsServerLastResult.1

Start monitoring H3C Fibre Channel SAN switch (Basic/Enhanced Zoning) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the H3C-FC-ZONE-SERVER-MIB::h3cFcZsServerLastResult OID value, configure state conditions and alerts, and monitor any H3C Fibre Channel SAN switch (Basic/Enhanced Zoning) from a single console.

OID Breakdown

Upper-level ancestors (10 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.2011huaweiHUAWEI-3COM-OID-MIB
1.3.6.1.4.1.2011.10h3cHUAWEI-3COM-OID-MIB
1.3.6.1.4.1.2011.10.2h3cCommonHUAWEI-3COM-OID-MIB
1.3.6.1.4.1.2011.10.2.127h3cSanH3C-VSAN-MIB
Numeric OIDNameModule
1.3.6.1.4.1.2011.10.2.127.9h3cFcZoneServerH3C-FC-ZONE-SERVER-MIB
1.3.6.1.4.1.2011.10.2.127.9.1h3cFcZoneMibObjectsH3C-FC-ZONE-SERVER-MIB
1.3.6.1.4.1.2011.10.2.127.9.1.1h3cFcZsConfigurationH3C-FC-ZONE-SERVER-MIB
1.3.6.1.4.1.2011.10.2.127.9.1.1.1h3cFcZsServerTableH3C-FC-ZONE-SERVER-MIB
1.3.6.1.4.1.2011.10.2.127.9.1.1.1.1h3cFcZsServerEntryH3C-FC-ZONE-SERVER-MIB
1.3.6.1.4.1.2011.10.2.127.9.1.1.1.1.6h3cFcZsServerLastResultH3C-FC-ZONE-SERVER-MIB