All MIBs › H3C-FC-NAME-SERVER-MIB › h3cFcNsPortLoginNotifyEnable
h3cFcNsPortLoginNotifyEnable
Module: H3C-FC-NAME-SERVER-MIB
OID (symbolic): H3C-FC-NAME-SERVER-MIB::h3cFcNsPortLoginNotifyEnable
OID (numeric): 1.3.6.1.4.1.2011.10.2.127.10.1.1.1.1
Node type: OBJECT-TYPE
Type: TruthValue
Access: read-write
Description: This object is used to determine whether h3cFcNsPortLoginNotify will be generated for Nx_Port locally logging in.
What is h3cFcNsPortLoginNotifyEnable?
This object determines whether the switch generates an h3cFcNsPortLoginNotify trap whenever a Fibre Channel Nx_Port logs in locally to this switch. An administrator enables this to get real-time SNMP alerts whenever a new storage device or HBA joins the fabric through this switch, useful for tracking fabric membership changes. Setting this to true means the next local Nx_Port login on this switch will generate a notification to the management station.
Examples
Walk all instances (SNMPv2c):
snmpwalk -v2c -c public <target> 1.3.6.1.4.1.2011.10.2.127.10.1.1.1.1 snmpwalk -v2c -c public <target> H3C-FC-NAME-SERVER-MIB::h3cFcNsPortLoginNotifyEnable
Get a specific instance (index 1):
snmpget -v2c -c public <target> 1.3.6.1.4.1.2011.10.2.127.10.1.1.1.1.1 snmpget -v2c -c public <target> H3C-FC-NAME-SERVER-MIB::h3cFcNsPortLoginNotifyEnable.1
Set instance 1 (SNMPv2c):
snmpset -v2c -c private <target> 1.3.6.1.4.1.2011.10.2.127.10.1.1.1.1.1 s <value>
Start monitoring H3C/HPE Fibre Channel SAN switch (Name Server) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the H3C-FC-NAME-SERVER-MIB::h3cFcNsPortLoginNotifyEnable OID value, configure state conditions and alerts, and monitor any H3C/HPE Fibre Channel SAN switch (Name Server) from a single console.
OID Breakdown
Upper-level ancestors (10 from the standard OID tree / other modules)
| Numeric OID | Name | Module |
|---|---|---|
| 1 | iso | LANART-AGENT |
| 1.3 | org | AirPair-MIB |
| 1.3.6 | dod | AirPair-MIB |
| 1.3.6.1 | internet | AirPair-MIB |
| 1.3.6.1.4 | private | AirPair-MIB |
| 1.3.6.1.4.1 | enterprises | AirPair-MIB |
| 1.3.6.1.4.1.2011 | huawei | EXPERTV2-MIB |
| 1.3.6.1.4.1.2011.10 | h3c | HUAWEI-3COM-OID-MIB |
| 1.3.6.1.4.1.2011.10.2 | h3cCommon | HUAWEI-3COM-OID-MIB |
| 1.3.6.1.4.1.2011.10.2.127 | h3cSan | H3C-VSAN-MIB |
| Numeric OID | Name | Module |
|---|---|---|
| 1.3.6.1.4.1.2011.10.2.127.10 | h3cFcNameServer | H3C-FC-NAME-SERVER-MIB |
| 1.3.6.1.4.1.2011.10.2.127.10.1 | h3cFcNameServerMibObjects | H3C-FC-NAME-SERVER-MIB |
| 1.3.6.1.4.1.2011.10.2.127.10.1.1 | h3cFcNsNotification | H3C-FC-NAME-SERVER-MIB |
| 1.3.6.1.4.1.2011.10.2.127.10.1.1.1 | h3cFcNsNotificationSwitch | H3C-FC-NAME-SERVER-MIB |
| 1.3.6.1.4.1.2011.10.2.127.10.1.1.1.1 | h3cFcNsPortLoginNotifyEnable | H3C-FC-NAME-SERVER-MIB |