H320MCU-MIB :: h320McuControlsCommands

MIB Reference — IPNetwork Monitor · Updated October 05, 2026

All MIBs › H320MCU-MIB › h320McuControlsCommands

h320McuControlsCommands

Module: H320MCU-MIB

OID (symbolic): H320MCU-MIB::h320McuControlsCommands

OID (numeric): 0.0.8.341.1.2.3.4.1

Node type: OBJECT-TYPE

Type: INTEGER

Access: read-write

Description: A value that represents a command for the H.320 MCU. 1. Other (for proprietary extensions) 2. Abrupt Restart (Drastic Restart) 3. Graceful Restart (Restart after all calls have terminated. Meanwhile, accept no calls) 4. Abrupt Shutdown (Drastic Restart) 5. Graceful Shutdown (Shutdown after all calls have terminated. Meanwhile, accept no calls) 6. Enter Quiescence Mode (Disable receiving of calls) 7. Exit Quiescence Mode (Enable receiving of calls) 8. Start Error/Log Reporting 9. Stop Error/Log Reporting 10. Reset Statistics 11. Run Diagnostic

What is h320McuControlsCommands?

A read-write command object used to remotely control the H.320 MCU: values include abrupt/graceful restart, abrupt/graceful shutdown, entering or exiting quiescence (stop/resume accepting calls), starting or stopping error logging, resetting statistics, and running diagnostics — for example, an admin sets it to gracefulShutdown(5) to drain active calls before taking the unit offline for maintenance.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 0.0.8.341.1.2.3.4.1
snmpwalk -v2c -c public <target> H320MCU-MIB::h320McuControlsCommands

Get a specific instance (index 1):

snmpget -v2c -c public <target> 0.0.8.341.1.2.3.4.1.1
snmpget -v2c -c public <target> H320MCU-MIB::h320McuControlsCommands.1

Set instance 1 (SNMPv2c):

snmpset -v2c -c private <target> 0.0.8.341.1.2.3.4.1.1 i <value>

Start monitoring Vendor-neutral ITU-T H.320 videoconferencing MCU, any manufacturer with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the H320MCU-MIB::h320McuControlsCommands OID value, configure state conditions and alerts, and monitor any Vendor-neutral ITU-T H.320 videoconferencing MCU, any manufacturer from a single console.

OID Breakdown

Upper-level ancestors (4 from the standard OID tree / other modules)
Numeric OIDNameModule
0ccittLANART-AGENT
0.0nullDLSW-MIB
0.0.8.341.1mmRootMULTI-MEDIA-MIB-TC
0.0.8.341.1.2mmH320RootMULTI-MEDIA-MIB-TC
Numeric OIDNameModule
0.0.8.341.1.2.3h320McuH320MCU-MIB
0.0.8.341.1.2.3.4h320McuControlsH320MCU-MIB
0.0.8.341.1.2.3.4.1h320McuControlsCommandsH320MCU-MIB