GUDEADS-ETS-MIB :: etsSecPowAvail

MIB Reference — IPNetwork Monitor · Updated October 05, 2026

All MIBs › GUDEADS-ETS-MIB › etsSecPowAvail

etsSecPowAvail

Module: GUDEADS-ETS-MIB

OID (symbolic): GUDEADS-ETS-MIB::etsSecPowAvail

OID (numeric): 1.3.6.1.4.1.28507.4.1.3

Node type: OBJECT-TYPE

Type: Integer32

Access: read-only

Description: not zero if secondary Power available

What is etsSecPowAvail?

This read-only integer reports whether secondary (backup) power is available to the device, with any non-zero value indicating availability per the description. It lets an admin confirm the redundant power path is healthy even while the device is normally running on primary power. For example, seeing a value of 0 here would warn that the backup power feed has failed, leaving the device without redundancy if primary power is lost.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.28507.4.1.3
snmpwalk -v2c -c public <target> GUDEADS-ETS-MIB::etsSecPowAvail

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.28507.4.1.3.1
snmpget -v2c -c public <target> GUDEADS-ETS-MIB::etsSecPowAvail.1

Start monitoring Gude Ethernet Terminal Server (ETS) remote console/power-control unit with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the GUDEADS-ETS-MIB::etsSecPowAvail OID value, configure state conditions and alerts, and monitor any Gude Ethernet Terminal Server (ETS) remote console/power-control unit from a single console.

OID Breakdown

Upper-level ancestors (7 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.28507gudeadsGUDEADS-EPC24X-MIB
Numeric OIDNameModule
1.3.6.1.4.1.28507.4gadsETSGUDEADS-ETS-MIB
1.3.6.1.4.1.28507.4.1etsObjectsGUDEADS-ETS-MIB
1.3.6.1.4.1.28507.4.1.3etsSecPowAvailGUDEADS-ETS-MIB