GUDEADS-EPC8X-MIB :: epc8PortSwitchCount

MIB Reference — IPNetwork Monitor · Updated October 05, 2026

All MIBs › GUDEADS-EPC8X-MIB › epc8PortSwitchCount

epc8PortSwitchCount

Module: GUDEADS-EPC8X-MIB

OID (symbolic): GUDEADS-EPC8X-MIB::epc8PortSwitchCount

OID (numeric): 1.3.6.1.4.1.28507.1.1.2.2.1.4

Node type: OBJECT-TYPE

Type: Counter32

Access: read-only

Description: The total number of switch actions ocurred on a PowerPort. Does not count switch commands which will not switch the ralay state, so just real relay switches are displayed here.

What is epc8PortSwitchCount?

This counter tracks the total number of actual relay-switch actions that have occurred on a PowerPort, explicitly excluding switch commands that didn't change the relay's state. Admins monitor this to gauge how often a given outlet has actually been power-cycled, which is useful for tracking wear or unexpected repeated cycling. For example, an unexpectedly high epc8PortSwitchCount on one port might indicate a device plugged into it is repeatedly triggering power cycles due to a fault.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.28507.1.1.2.2.1.4
snmpwalk -v2c -c public <target> GUDEADS-EPC8X-MIB::epc8PortSwitchCount

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.28507.1.1.2.2.1.4.1
snmpget -v2c -c public <target> GUDEADS-EPC8X-MIB::epc8PortSwitchCount.1

Start monitoring Gude IP power distribution units with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the GUDEADS-EPC8X-MIB::epc8PortSwitchCount OID value, configure state conditions and alerts, and monitor any Gude IP power distribution units from a single console.

How to Use in IPNetwork Monitor

Select a Gude IP power distribution unit as the target host to create a monitor — the SNMP service should be up and running on it. Click New Monitor, then check SNMP Custom on the Favorites tab, click Next, and confirm the host. On the next page, click Select... to open the built-in SNMP MIB Browser and type epc8PortSwitchCount into the Find box to locate it in the OID tree, selecting the specific row/instance you want to monitor since this is a table column, then select it and click OK. The total number of switch actions ocurred on a PowerPort. On the monitor's Main parameters page you can set the target's SNMP port (default 161), credentials, polling interval, and other settings — see the SNMP Monitor help for details. On the State conditions and Alerting tabs, configure when the monitor should change state and trigger an alert; since this is a Counter32-type OID, Value bounds is the most useful condition here — trigger an alert if the counter increases sharply between polls relative to its normal baseline, since an unexpected spike often reflects a real change in traffic or activity. Click Finish to create the monitor; you can adjust any parameter later.

OID Breakdown

Upper-level ancestors (7 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.28507gudeadsGUDEADS-EPC24X-MIB
Numeric OIDNameModule
1.3.6.1.4.1.28507.1gadsEPC8GUDEADS-EPC8X-MIB
1.3.6.1.4.1.28507.1.1epc8ObjectsGUDEADS-EPC8X-MIB
1.3.6.1.4.1.28507.1.1.2epc8powerportsGUDEADS-EPC8X-MIB
1.3.6.1.4.1.28507.1.1.2.2epc8portTableGUDEADS-EPC8X-MIB
1.3.6.1.4.1.28507.1.1.2.2.1epc8portEntryGUDEADS-EPC8X-MIB
1.3.6.1.4.1.28507.1.1.2.2.1.4epc8PortSwitchCountGUDEADS-EPC8X-MIB