GIGAswitchEthernet-MIB :: gsEPortFlowControlMode

MIB Reference — IPNetwork Monitor · Updated October 05, 2026

All MIBs › GIGAswitchEthernet-MIB › gsEPortFlowControlMode

gsEPortFlowControlMode

Module: GIGAswitchEthernet-MIB

OID (symbolic): GIGAswitchEthernet-MIB::gsEPortFlowControlMode

OID (numeric): 1.3.6.1.4.1.36.2.18.39.3.6.2.1.1.21

Node type: OBJECT-TYPE

Type: INTEGER

Access: read-write

Description: Flow control is used to prevent or reduce the dropping of frames due to the lack of buffer space. Overall, networks are more efficient when a sending station is asked to pause in its sending process, rather than having the transmitted frames dropped.

Flow control is not as efficient when used in conjunction with a shared ports, i.e. when used with a repeater. Therefore, flow control is not recommended for a port connected to shared topologies.

Flow control is most effective when the port is directly connected to an end-station, especially when connected to a server. Flow control is recommended for ports connected directly to end-stations.

When the port is in half-duplex mode, back pressure is used to control the incoming flow. Back pressure essentially forces collisions for short periods of time.

When the port is in full-duplex mode, IEEE 802.3 standard pause frames are used to control the incoming flow.

Note that setting an ether-gigabit(4) port to enable-with-aggressive-backoff(3) results in an error.

What is gsEPortFlowControlMode?

Controls 802.3x flow control on this port: full-duplex ports use standard PAUSE frames, half-duplex ports use back-pressure (forced collisions). Admins enable this on ports connected directly to servers/end-stations (where it's most effective) but avoid it on shared/repeater segments; setting enable-with-aggressive-backoff(3) on a gigabit port is rejected outright.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.36.2.18.39.3.6.2.1.1.21
snmpwalk -v2c -c public <target> GIGAswitchEthernet-MIB::gsEPortFlowControlMode

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.36.2.18.39.3.6.2.1.1.21.1
snmpget -v2c -c public <target> GIGAswitchEthernet-MIB::gsEPortFlowControlMode.1

Set instance 1 (SNMPv2c):

snmpset -v2c -c private <target> 1.3.6.1.4.1.36.2.18.39.3.6.2.1.1.21.1 i <value>

SNMPv3 example:

snmpget -v3 -l authPriv -u snmpv3-user -a SHA -A "AuthPassword1" -x AES -X "PrivPassword1" <target> gsEPortFlowControlMode.1

Start monitoring Digital Equipment Corporation (DEC) GIGAswitch/Ethernet chassis switch (legacy) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the GIGAswitchEthernet-MIB::gsEPortFlowControlMode OID value, configure state conditions and alerts, and monitor any Digital Equipment Corporation (DEC) GIGAswitch/Ethernet chassis switch (legacy) from a single console.

OID Breakdown

Upper-level ancestors (9 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.36decCMU-MIB
1.3.6.1.4.1.36.2emaDEC-ATM-CHASSIS-MIB
1.3.6.1.4.1.36.2.18decMIBextensionDEC-ATM-CHASSIS-MIB
Numeric OIDNameModule
1.3.6.1.4.1.36.2.18.39gsEMIBGIGAswitchEthernet-MIB
1.3.6.1.4.1.36.2.18.39.3gsEChassisGIGAswitchEthernet-MIB
1.3.6.1.4.1.36.2.18.39.3.6gsEPortsGIGAswitchEthernet-MIB
1.3.6.1.4.1.36.2.18.39.3.6.2gsEPortFlowControlMgtGIGAswitchEthernet-MIB
1.3.6.1.4.1.36.2.18.39.3.6.2.1gsEPortFlowControlTableGIGAswitchEthernet-MIB
1.3.6.1.4.1.36.2.18.39.3.6.2.1.1gsEPortFlowControlEntryGIGAswitchEthernet-MIB
1.3.6.1.4.1.36.2.18.39.3.6.2.1.1.21gsEPortFlowControlModeGIGAswitchEthernet-MIB