All MIBs › GIGAswitchEthernet-MIB › gsEPortCategoryMode
gsEPortCategoryMode
Module: GIGAswitchEthernet-MIB
OID (symbolic): GIGAswitchEthernet-MIB::gsEPortCategoryMode
OID (numeric): 1.3.6.1.4.1.36.2.18.39.3.6.8.1.1.81
Node type: OBJECT-TYPE
Type: INTEGER
Access: read-write
Description: By default, all ports are considered service ports. A service port is a port that provides a networks service such as a connection to a server, other switches, or the like. A service port will trigger the service port event for status changes with the alarm severity and will trigger an alarm in the alarm table on link failure.
In contrast, user ports trigger the user link event with warning severity. They do not trigger an alarm upon link failures. User ports are useful to prevent floods of traps or entries in the alarm table. This is especially true for ports connected to user hosts that power up in the morning and power down again at the end of the work day.
What is gsEPortCategoryMode?
Classifies the port as a servicePort(2) (default), triggering alarm-severity events and an alarm-table entry on link failure, or a userPort(1), which only triggers warning-severity link events and never populates the alarm table. Admins mark end-user desktop ports as userPort(1) so routine power-on/power-off at the start/end of the workday doesn't flood the alarm table, while keeping uplinks and server ports as servicePort(2) for proper alerting.
Examples
Walk all instances (SNMPv2c):
snmpwalk -v2c -c public <target> 1.3.6.1.4.1.36.2.18.39.3.6.8.1.1.81 snmpwalk -v2c -c public <target> GIGAswitchEthernet-MIB::gsEPortCategoryMode
Get a specific instance (index 1):
snmpget -v2c -c public <target> 1.3.6.1.4.1.36.2.18.39.3.6.8.1.1.81.1 snmpget -v2c -c public <target> GIGAswitchEthernet-MIB::gsEPortCategoryMode.1
Set instance 1 (SNMPv2c):
snmpset -v2c -c private <target> 1.3.6.1.4.1.36.2.18.39.3.6.8.1.1.81.1 i <value>
Start monitoring Digital Equipment Corporation (DEC) GIGAswitch/Ethernet chassis switch (legacy) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the GIGAswitchEthernet-MIB::gsEPortCategoryMode OID value, configure state conditions and alerts, and monitor any Digital Equipment Corporation (DEC) GIGAswitch/Ethernet chassis switch (legacy) from a single console.
OID Breakdown
Upper-level ancestors (9 from the standard OID tree / other modules)
| Numeric OID | Name | Module |
|---|---|---|
| 1 | iso | LANART-AGENT |
| 1.3 | org | AirPair-MIB |
| 1.3.6 | dod | AirPair-MIB |
| 1.3.6.1 | internet | AirPair-MIB |
| 1.3.6.1.4 | private | AirPair-MIB |
| 1.3.6.1.4.1 | enterprises | AirPair-MIB |
| 1.3.6.1.4.1.36 | dec | CMU-MIB |
| 1.3.6.1.4.1.36.2 | ema | DEC-ATM-CHASSIS-MIB |
| 1.3.6.1.4.1.36.2.18 | decMIBextension | DEC-ATM-CHASSIS-MIB |
| Numeric OID | Name | Module |
|---|---|---|
| 1.3.6.1.4.1.36.2.18.39 | gsEMIB | GIGAswitchEthernet-MIB |
| 1.3.6.1.4.1.36.2.18.39.3 | gsEChassis | GIGAswitchEthernet-MIB |
| 1.3.6.1.4.1.36.2.18.39.3.6 | gsEPorts | GIGAswitchEthernet-MIB |
| 1.3.6.1.4.1.36.2.18.39.3.6.8 | gsEPortCategoryMgt | GIGAswitchEthernet-MIB |
| 1.3.6.1.4.1.36.2.18.39.3.6.8.1 | gsEPortCategoryTable | GIGAswitchEthernet-MIB |
| 1.3.6.1.4.1.36.2.18.39.3.6.8.1.1 | gsEPortCategoryEntry | GIGAswitchEthernet-MIB |
| 1.3.6.1.4.1.36.2.18.39.3.6.8.1.1.81 | gsEPortCategoryMode | GIGAswitchEthernet-MIB |