GEPARALLELUPS-MIB :: upsTestIdsixth

MIB Reference — IPNetwork Monitor · Updated October 05, 2026

All MIBs › GEPARALLELUPS-MIB › upsTestIdsixth

upsTestIdsixth

Module: GEPARALLELUPS-MIB

OID (symbolic): GEPARALLELUPS-MIB::upsTestIdsixth

OID (numeric): 1.3.6.1.4.1.818.1.1.16.7.1

Node type: OBJECT-TYPE

Type: OBJECT IDENTIFIER

Access: read-write

Description: The test is named by an OBJECT IDENTIFIER which allows a standard mechanism for the initiation of tests, including the well known tests identified in this document as well as those introduced by a particular implementation, i.e., as documented in the private enterprise MIB definition for the device.

Setting this variable initiates the named test. Sets to this variable require the presence of upsTestSpinLock in the same SNMP message.

The set request will be rejected with an appropriate error message if the requested test cannot be performed, including attempts to start a test when another test is already in progress. The status of the current or last test is maintained in upsTestResultsSummary. Tests in progress may be aborted by setting the upsTestId variable to upsTestAbortTestInProgress.

Read operations return the value of the name of the test in progress if a test is in progress or the name of the last test performed if no test is in progress, unless no test has been run, in which case the well known value upsTestNoTestsInitiated is returned.(*)

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.818.1.1.16.7.1
snmpwalk -v2c -c public <target> GEPARALLELUPS-MIB::upsTestIdsixth

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.818.1.1.16.7.1.1
snmpget -v2c -c public <target> GEPARALLELUPS-MIB::upsTestIdsixth.1

Set instance 1 (SNMPv2c):

snmpset -v2c -c private <target> 1.3.6.1.4.1.818.1.1.16.7.1.1 s <value>

Start monitoring GE Digital Energy parallel/redundant UPS system with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the GEPARALLELUPS-MIB::upsTestIdsixth OID value, configure state conditions and alerts, and monitor any GE Digital Energy parallel/redundant UPS system from a single console.

OID Breakdown

Upper-level ancestors (11 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.818imvGE-PARALLELUPS
1.3.6.1.4.1.818.1geHardwareGE-PARALLELUPS
1.3.6.1.4.1.818.1.1geUPSGE-PARALLELUPS
1.3.6.1.4.1.818.1.1.16geSixthUPSGE-PARALLELUPS
1.3.6.1.4.1.818.1.1.16.7upsTest_sixthGE-PARALLELUPS
Numeric OIDNameModule
1.3.6.1.4.1.818.1.1.16.7.1upsTestIdsixthGEPARALLELUPS-MIB