GEPARALLELUPS-MIB :: upsRebootWithDurationfourth

MIB Reference — IPNetwork Monitor · Updated October 05, 2026

All MIBs › GEPARALLELUPS-MIB › upsRebootWithDurationfourth

upsRebootWithDurationfourth

Module: GEPARALLELUPS-MIB

OID (symbolic): GEPARALLELUPS-MIB::upsRebootWithDurationfourth

OID (numeric): 1.3.6.1.4.1.818.1.1.14.8.4

Node type: OBJECT-TYPE

Type: Integer32

Access: read-write

Description: Setting this object will immediately shutdown (i.e., turn off) either the UPS output or the UPS system (as determined by the value of upsShutdownType at the time of shutdown) for a period equal to the indicated number of fourths, after which time the output will be started, including starting the UPS, if necessary. If the number of fourths required to perform the request is greater than the requested duration, then the requested shutdown and startup cycle shall be performed in the minimum time possible, but in no case shall this require more than the requested duration plus 60 fourths. When read, upsRebootWithDuration shall return the number of fourths remaining in the countdown, or -1 if no countdown is in progress. If the startup should occur during a utility failure, the startup shall not occur until the utility power is restored.(*)

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.818.1.1.14.8.4
snmpwalk -v2c -c public <target> GEPARALLELUPS-MIB::upsRebootWithDurationfourth

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.818.1.1.14.8.4.1
snmpget -v2c -c public <target> GEPARALLELUPS-MIB::upsRebootWithDurationfourth.1

Set instance 1 (SNMPv2c):

snmpset -v2c -c private <target> 1.3.6.1.4.1.818.1.1.14.8.4.1 i <value>

Start monitoring GE Digital Energy parallel/redundant UPS system with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the GEPARALLELUPS-MIB::upsRebootWithDurationfourth OID value, configure state conditions and alerts, and monitor any GE Digital Energy parallel/redundant UPS system from a single console.

OID Breakdown

Upper-level ancestors (11 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.818imvGE-PARALLELUPS
1.3.6.1.4.1.818.1geHardwareGE-PARALLELUPS
1.3.6.1.4.1.818.1.1geUPSGE-PARALLELUPS
1.3.6.1.4.1.818.1.1.14geFourthUPSGE-PARALLELUPS
1.3.6.1.4.1.818.1.1.14.8upsControl_fourthGE-PARALLELUPS
Numeric OIDNameModule
1.3.6.1.4.1.818.1.1.14.8.4upsRebootWithDurationfourthGEPARALLELUPS-MIB