All MIBs › GDCUAS7624-MIB › uas7624LOSLocal
uas7624LOSLocal
Module: GDCUAS7624-MIB
OID (symbolic): GDCUAS7624-MIB::uas7624LOSLocal
OID (numeric): 1.3.6.1.4.1.498.18.1.6.2.1.2
Node type: OBJECT-TYPE
Type: INTEGER
Access: read-write
Description: Disables or enables the alarm on the Major buss or Minor Buss. SCinstance: [L]ine=5 [i]nterface=0
What is uas7624LOSLocal?
This read-write setting controls whether a Loss Of Signal condition on the T1 line (line 5) activates the chassis's Major alarm bus, Minor alarm bus, or is disabled. An admin enables this on the Major bus so a LOS condition trips the rack's external major-alarm relay for on-site alerting.
Examples
Walk all instances (SNMPv2c):
snmpwalk -v2c -c public <target> 1.3.6.1.4.1.498.18.1.6.2.1.2 snmpwalk -v2c -c public <target> GDCUAS7624-MIB::uas7624LOSLocal
Get a specific instance (index 1):
snmpget -v2c -c public <target> 1.3.6.1.4.1.498.18.1.6.2.1.2.1 snmpget -v2c -c public <target> GDCUAS7624-MIB::uas7624LOSLocal.1
Set instance 1 (SNMPv2c):
snmpset -v2c -c private <target> 1.3.6.1.4.1.498.18.1.6.2.1.2.1 i <value>
Start monitoring General DataComm (GDC) UAS7624 24-port universal access system/channel bank with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the GDCUAS7624-MIB::uas7624LOSLocal OID value, configure state conditions and alerts, and monitor any General DataComm (GDC) UAS7624 24-port universal access system/channel bank from a single console.
OID Breakdown
Upper-level ancestors (7 from the standard OID tree / other modules)
| Numeric OID | Name | Module |
|---|---|---|
| 1 | iso | LANART-AGENT |
| 1.3 | org | AirPair-MIB |
| 1.3.6 | dod | AirPair-MIB |
| 1.3.6.1 | internet | AirPair-MIB |
| 1.3.6.1.4 | private | AirPair-MIB |
| 1.3.6.1.4.1 | enterprises | AirPair-MIB |
| 1.3.6.1.4.1.498 | gdc | GDC7616-MIB |
| Numeric OID | Name | Module |
|---|---|---|
| 1.3.6.1.4.1.498.18 | niudiu | GDCUAS7624-MIB |
| 1.3.6.1.4.1.498.18.1 | uas7624System | GDCUAS7624-MIB |
| 1.3.6.1.4.1.498.18.1.6 | uas7624AlarmConfig | GDCUAS7624-MIB |
| 1.3.6.1.4.1.498.18.1.6.2 | uas7624LocalAlarmConfigTable | GDCUAS7624-MIB |
| 1.3.6.1.4.1.498.18.1.6.2.1 | uas7624LocalAlarmConfigEntry | GDCUAS7624-MIB |
| 1.3.6.1.4.1.498.18.1.6.2.1.2 | uas7624LOSLocal | GDCUAS7624-MIB |