All MIBs › GDCUAS7624-MIB › uas7624CRCLocal
uas7624CRCLocal
Module: GDCUAS7624-MIB
OID (symbolic): GDCUAS7624-MIB::uas7624CRCLocal
OID (numeric): 1.3.6.1.4.1.498.18.1.6.2.1.7
Node type: OBJECT-TYPE
Type: INTEGER
Access: read-write
Description: Disables or enables the alarm on the Major buss or Minor Buss. SCinstance: [L]ine=5 [i]nterface=0
What is uas7624CRCLocal?
This read-write setting controls whether a CRC error condition on the T1 line (line 5) activates the chassis's Major alarm bus, Minor alarm bus, or is disabled. An admin enables this to make CRC error bursts trigger a visible backplane alarm rather than only showing up in polled statistics.
Examples
Walk all instances (SNMPv2c):
snmpwalk -v2c -c public <target> 1.3.6.1.4.1.498.18.1.6.2.1.7 snmpwalk -v2c -c public <target> GDCUAS7624-MIB::uas7624CRCLocal
Get a specific instance (index 1):
snmpget -v2c -c public <target> 1.3.6.1.4.1.498.18.1.6.2.1.7.1 snmpget -v2c -c public <target> GDCUAS7624-MIB::uas7624CRCLocal.1
Set instance 1 (SNMPv2c):
snmpset -v2c -c private <target> 1.3.6.1.4.1.498.18.1.6.2.1.7.1 i <value>
Start monitoring General DataComm (GDC) UAS7624 24-port universal access system/channel bank with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the GDCUAS7624-MIB::uas7624CRCLocal OID value, configure state conditions and alerts, and monitor any General DataComm (GDC) UAS7624 24-port universal access system/channel bank from a single console.
OID Breakdown
Upper-level ancestors (7 from the standard OID tree / other modules)
| Numeric OID | Name | Module |
|---|---|---|
| 1 | iso | LANART-AGENT |
| 1.3 | org | AirPair-MIB |
| 1.3.6 | dod | AirPair-MIB |
| 1.3.6.1 | internet | AirPair-MIB |
| 1.3.6.1.4 | private | AirPair-MIB |
| 1.3.6.1.4.1 | enterprises | AirPair-MIB |
| 1.3.6.1.4.1.498 | gdc | GDC7616-MIB |
| Numeric OID | Name | Module |
|---|---|---|
| 1.3.6.1.4.1.498.18 | niudiu | GDCUAS7624-MIB |
| 1.3.6.1.4.1.498.18.1 | uas7624System | GDCUAS7624-MIB |
| 1.3.6.1.4.1.498.18.1.6 | uas7624AlarmConfig | GDCUAS7624-MIB |
| 1.3.6.1.4.1.498.18.1.6.2 | uas7624LocalAlarmConfigTable | GDCUAS7624-MIB |
| 1.3.6.1.4.1.498.18.1.6.2.1 | uas7624LocalAlarmConfigEntry | GDCUAS7624-MIB |
| 1.3.6.1.4.1.498.18.1.6.2.1.7 | uas7624CRCLocal | GDCUAS7624-MIB |