GDCUAS7022-MIB :: uas7022AlarmStatus

MIB Reference — IPNetwork Monitor · Updated October 05, 2026

All MIBs › GDCUAS7022-MIB › uas7022AlarmStatus

uas7022AlarmStatus

Module: GDCUAS7022-MIB

OID (symbolic): GDCUAS7022-MIB::uas7022AlarmStatus

OID (numeric): 1.3.6.1.4.1.498.6.13.2.1.1.6

Node type: OBJECT-TYPE

Type: OCTET STRING

Access: read-only

Description: Returns a bit-wise Status of alarms Octet 1 bit 7 - not used bit 6 - NIUA_LOS bit 5 - NIUA_LOF bit 4 - NIUA_AIS bit 3 - NIUA_LCV bit 2 - NIUA TIMING LOSS bit 1 - NIUA_NE_ES bit 0 - NIUA_NE_BBE

Octet 2 bit 7 - not used bit 6 - NIUA_NE_SES bit 5 - NIUA_NE_UAS bit 4 - NIUA_FE_ES bit 3 - NIUA_FE_BBE bit 2 - NIUA_FE_SES bit 1 - NIUA_FE_UAS bit 0 - NIUA_RAI

Octet 3 bit 7 - not used bit 6 - NIUB_LOS bit 5 - NIUB_LOF bit 4 - NIUB_AIS bit 3 - NIUB_LCV bit 2 - NIUB TIMING LOSS bit 1 - NIUB_NE_ES bit 0 - NIUB_NE_BBE

Octet 4 bit 7 - not used bit 6 - NIUB_NE_SES bit 5 - NIUB_NE_UAS bit 4 - NIUB_FE_ES bit 3 - NIUB_FE_BBE bit 2 - NIUB_FE_SES bit 1 - NIUB_FE_UAS bit 0 - NIUB_RAI

Octet 5 bit 7 - not used bit 6 - future use bit 5 - future use bit 4 - future use bit 3 - future use bit 2 - future use bit 1 - future use bit 0 - Power-up Alarm Valid [i]nterface = 0

What is uas7022AlarmStatus?

Returns a 5-octet bitmap of active alarm conditions on the card, covering per-NIU LOS, LOF, AIS, LCV, timing loss, near-end/far-end ES/BBE/SES/UAS, RAI, and a power-up alarm bit. Admins poll this to get a compact, single-read summary of everything currently wrong with the circuit rather than querying each condition individually.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.498.6.13.2.1.1.6
snmpwalk -v2c -c public <target> GDCUAS7022-MIB::uas7022AlarmStatus

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.498.6.13.2.1.1.6.1
snmpget -v2c -c public <target> GDCUAS7022-MIB::uas7022AlarmStatus.1

Start monitoring General DataComm (GDC) UAS7022 universal access system with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the GDCUAS7022-MIB::uas7022AlarmStatus OID value, configure state conditions and alerts, and monitor any General DataComm (GDC) UAS7022 universal access system from a single console.

OID Breakdown

Upper-level ancestors (8 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.498gdcDMA200-MIB
1.3.6.1.4.1.498.6dsx1GDC-5553-MIB
Numeric OIDNameModule
1.3.6.1.4.1.498.6.13uas7022GDCUAS7022-MIB
1.3.6.1.4.1.498.6.13.2uas7022MaintenanceGDCUAS7022-MIB
1.3.6.1.4.1.498.6.13.2.1uas7022MaintenanceTableGDCUAS7022-MIB
1.3.6.1.4.1.498.6.13.2.1.1uas7022MaintenanceEntryGDCUAS7022-MIB
1.3.6.1.4.1.498.6.13.2.1.1.6uas7022AlarmStatusGDCUAS7022-MIB