GDCSC616-MIB :: bqlTestPattern

MIB Reference — IPNetwork Monitor · Updated September 14, 2026

All MIBsGDCSC616-MIBbqlTestPattern

bqlTestPattern

Module: GDCSC616-MIB

OID (symbolic): GDCSC616-MIB::bqlTestPattern

OID (numeric): 1.3.6.1.4.1.498.10.3.1.3

Node type: OBJECT-TYPE

Type: INTEGER

Access: read-write

Description: Object to select loop and channel test pattern for SC616, DC610, DC612.

What is bqlTestPattern?

Selects the bit-error-rate test pattern, 2047 or 511, used for loop and channel testing on the SC616, DC610, or DC612. An admin sets this before running a BERT test to match whichever pattern the far-end test set or loopback expects.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.498.10.3.1.3
snmpwalk -v2c -c public <target> GDCSC616-MIB::bqlTestPattern

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.498.10.3.1.3.1
snmpget -v2c -c public <target> GDCSC616-MIB::bqlTestPattern.1

Set instance 1 (SNMPv2c):

snmpset -v2c -c private <target> 1.3.6.1.4.1.498.10.3.1.3.1 i <value>

Start monitoring General DataComm shelf controllers/chassis with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the GDCSC616-MIB::bqlTestPattern OID value, configure state conditions and alerts, and monitor any General DataComm shelf controllers/chassis from a single console.

OID Breakdown

Upper-level ancestors (7 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.498gdcGDC7616-MIB
Numeric OIDNameModule
1.3.6.1.4.1.498.10bqlGDCSC616-MIB
1.3.6.1.4.1.498.10.3bqlConfigTableGDCSC616-MIB
1.3.6.1.4.1.498.10.3.1bqlConfigEntryGDCSC616-MIB
1.3.6.1.4.1.498.10.3.1.3bqlTestPatternGDCSC616-MIB