GDCSC616-MIB :: bqlSC616LEDStatus

MIB Reference — IPNetwork Monitor · Updated September 14, 2026

All MIBsGDCSC616-MIBbqlSC616LEDStatus

bqlSC616LEDStatus

Module: GDCSC616-MIB

OID (symbolic): GDCSC616-MIB::bqlSC616LEDStatus

OID (numeric): 1.3.6.1.4.1.498.10.8.1.2

Node type: OBJECT-TYPE

Type: OCTET STRING

Access: read-only

Description: The GDC SC616 front panel LED Status. A value of 1 means on, 0 is off. byte 1 bit 7 (1.7) - not used 1.6 - test mode 1.5 - alarm on 1.4 - loop 1 line loopback 1.3 - loop 1 channel 1 send data transitions 1.2 - loop 1 channel 1 receive data transitions 1.1 - loop 1 channel 2 send data transitions 1.0 - loop 1 channel 2 receive data transitions

2.7 - not used 2.6 - not used 2.5 - not used 2.4 - loop 2 line loopback 2.3 - loop 2 channel 1 send data transitions 2.2 - loop 2 channel 1 receive data transitions 2.1 - loop 2 channel 2 send data transitions 2.0 - loop 2 channel 2 receive data transitions

3.7 - not used 3.6 - not used 3.5 - not used 3.4 - loop 3 line loopback 3.3 - loop 3 channel 1 send data transitions 3.2 - loop 3 channel 1 receive data transitions 3.1 - loop 3 channel 2 send data transitions 3.0 - loop 3 channel 2 receive data transitions

What is bqlSC616LEDStatus?

A 3-byte bitmask mirroring the SC616's front-panel LEDs, with each bit indicating test mode, alarm, line loopback, or send/receive data transitions for each of the unit's three loops and their two channels. An admin polls this to check the unit's front-panel indicator state remotely, without needing to be physically at the equipment.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.498.10.8.1.2
snmpwalk -v2c -c public <target> GDCSC616-MIB::bqlSC616LEDStatus

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.498.10.8.1.2.1
snmpget -v2c -c public <target> GDCSC616-MIB::bqlSC616LEDStatus.1

Start monitoring General DataComm shelf controllers/chassis with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the GDCSC616-MIB::bqlSC616LEDStatus OID value, configure state conditions and alerts, and monitor any General DataComm shelf controllers/chassis from a single console.

OID Breakdown

Upper-level ancestors (7 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.498gdcGDC7616-MIB
Numeric OIDNameModule
1.3.6.1.4.1.498.10bqlGDCSC616-MIB
1.3.6.1.4.1.498.10.8bqlSC616LEDStatusTableGDCSC616-MIB
1.3.6.1.4.1.498.10.8.1bqlSC616LEDEntryGDCSC616-MIB
1.3.6.1.4.1.498.10.8.1.2bqlSC616LEDStatusGDCSC616-MIB