All MIBs › GDCSC616-MIB › bqlMasterTXClkSrc
bqlMasterTXClkSrc
Module: GDCSC616-MIB
OID (symbolic): GDCSC616-MIB::bqlMasterTXClkSrc
OID (numeric): 1.3.6.1.4.1.498.10.5.1.2
Node type: OBJECT-TYPE
Type: INTEGER
Access: read-write
Description: Object to option the Loop master transmit clock source. This is for the SC616 only.
What is bqlMasterTXClkSrc?
Selects which internal clock source, XTC1 or XTC2, the SC616 loop uses as its master transmit clock. An admin sets this when synchronizing multiple loops to a common timing reference, choosing whichever crystal/clock source is designated as the network timing master.
Examples
Walk all instances (SNMPv2c):
snmpwalk -v2c -c public <target> 1.3.6.1.4.1.498.10.5.1.2 snmpwalk -v2c -c public <target> GDCSC616-MIB::bqlMasterTXClkSrc
Get a specific instance (index 1):
snmpget -v2c -c public <target> 1.3.6.1.4.1.498.10.5.1.2.1 snmpget -v2c -c public <target> GDCSC616-MIB::bqlMasterTXClkSrc.1
Set instance 1 (SNMPv2c):
snmpset -v2c -c private <target> 1.3.6.1.4.1.498.10.5.1.2.1 i <value>
Start monitoring General DataComm shelf controllers/chassis with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the GDCSC616-MIB::bqlMasterTXClkSrc OID value, configure state conditions and alerts, and monitor any General DataComm shelf controllers/chassis from a single console.
OID Breakdown
Upper-level ancestors (7 from the standard OID tree / other modules)
| Numeric OID | Name | Module |
|---|---|---|
| 1 | iso | LANART-AGENT |
| 1.3 | org | AirPair-MIB |
| 1.3.6 | dod | AirPair-MIB |
| 1.3.6.1 | internet | AirPair-MIB |
| 1.3.6.1.4 | private | AirPair-MIB |
| 1.3.6.1.4.1 | enterprises | AirPair-MIB |
| 1.3.6.1.4.1.498 | gdc | GDC7616-MIB |
| Numeric OID | Name | Module |
|---|---|---|
| 1.3.6.1.4.1.498.10 | bql | GDCSC616-MIB |
| 1.3.6.1.4.1.498.10.5 | bqlConfig2Table | GDCSC616-MIB |
| 1.3.6.1.4.1.498.10.5.1 | bqlConfig2Entry | GDCSC616-MIB |
| 1.3.6.1.4.1.498.10.5.1.2 | bqlMasterTXClkSrc | GDCSC616-MIB |