All MIBs › GDCSC613-MIB › bql613MasterTXClkSrc
bql613MasterTXClkSrc
Module: GDCSC613-MIB
OID (symbolic): GDCSC613-MIB::bql613MasterTXClkSrc
OID (numeric): 1.3.6.1.4.1.498.12.1.3.1.4
Node type: OBJECT-TYPE
Type: INTEGER
Access: read-write
Description: Object to option the Loop master transmit clock source.
What is bql613MasterTXClkSrc?
Selects the loop's master transmit clock source: internal(1) uses the unit's own clock, external(2) synchronizes to a clock supplied from outside the unit; get this right or the ISDN link can fail to sync.
Examples
Walk all instances (SNMPv2c):
snmpwalk -v2c -c public <target> 1.3.6.1.4.1.498.12.1.3.1.4 snmpwalk -v2c -c public <target> GDCSC613-MIB::bql613MasterTXClkSrc
Get a specific instance (index 1):
snmpget -v2c -c public <target> 1.3.6.1.4.1.498.12.1.3.1.4.1 snmpget -v2c -c public <target> GDCSC613-MIB::bql613MasterTXClkSrc.1
Set instance 1 (SNMPv2c):
snmpset -v2c -c private <target> 1.3.6.1.4.1.498.12.1.3.1.4.1 i <value>
Start monitoring General DataComm (GDC) SC613 shelf/chassis controller with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the GDCSC613-MIB::bql613MasterTXClkSrc OID value, configure state conditions and alerts, and monitor any General DataComm (GDC) SC613 shelf/chassis controller from a single console.
OID Breakdown
Upper-level ancestors (8 from the standard OID tree / other modules)
| Numeric OID | Name | Module |
|---|---|---|
| 1 | iso | LANART-AGENT |
| 1.3 | org | AirPair-MIB |
| 1.3.6 | dod | AirPair-MIB |
| 1.3.6.1 | internet | AirPair-MIB |
| 1.3.6.1.4 | private | AirPair-MIB |
| 1.3.6.1.4.1 | enterprises | AirPair-MIB |
| 1.3.6.1.4.1.498 | gdc | DMA200-MIB |
| 1.3.6.1.4.1.498.12 | bql2 | GDC7616-MIB |
| Numeric OID | Name | Module |
|---|---|---|
| 1.3.6.1.4.1.498.12.1 | bql613 | GDCSC613-MIB |
| 1.3.6.1.4.1.498.12.1.3 | bql613ConfigTable | GDCSC613-MIB |
| 1.3.6.1.4.1.498.12.1.3.1 | bql613ConfigEntry | GDCSC613-MIB |
| 1.3.6.1.4.1.498.12.1.3.1.4 | bql613MasterTXClkSrc | GDCSC613-MIB |