GDCDSX1-MIB :: gdcDsx1AdminLineBuildout

MIB Reference — IPNetwork Monitor · Updated September 14, 2026

All MIBsGDCDSX1-MIBgdcDsx1AdminLineBuildout

gdcDsx1AdminLineBuildout

Module: GDCDSX1-MIB

OID (symbolic): GDCDSX1-MIB::gdcDsx1AdminLineBuildout

OID (numeric): 1.3.6.1.4.1.498.6.1.3.1.1.5

Node type: OBJECT-TYPE

Type: INTEGER

Access: read-write

Description: This variable is used to set the Transmit Ntwk Build-Out value on the network side and is only valid if the gdcDsx1InterfaceType is set for ds1(1). The values, in sequence, describe:

'auto' indicates auto detection of receive level to determine the appropriate Ntwk build out without controller intervention

'man00dB' indicates manual selection of 0.0 dB transmit Ntwk build out

'man75dB' indicates manual selection of -7.5 dB transmit Ntwk build out

'man150dB' indicates manual selection of -15.0 dB transmit Ntwk build out

Set/get of auto requires a reading of gdcDsx1OperLineBuildOut to determine the selection of the Ntwk buildout. Caution must be used when setting auto since only one unit on a link can be in auto at a given time.

Default value: man00dB (2)

What is gdcDsx1AdminLineBuildout?

This sets the transmit line build-out (attenuation) applied on the network side: auto lets the unit determine it from the receive level, while man00dB, man75dB, and man150dB manually fix it at 0, -7.5, or -15 dB. Only one unit on a given link should be left in auto at a time to avoid conflicting settings.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.498.6.1.3.1.1.5
snmpwalk -v2c -c public <target> GDCDSX1-MIB::gdcDsx1AdminLineBuildout

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.498.6.1.3.1.1.5.1
snmpget -v2c -c public <target> GDCDSX1-MIB::gdcDsx1AdminLineBuildout.1

Set instance 1 (SNMPv2c):

snmpset -v2c -c private <target> 1.3.6.1.4.1.498.6.1.3.1.1.5.1 i <value>

Start monitoring General DataComm (GDC) DSX-1 unit (legacy) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the GDCDSX1-MIB::gdcDsx1AdminLineBuildout OID value, configure state conditions and alerts, and monitor any General DataComm (GDC) DSX-1 unit (legacy) from a single console.

OID Breakdown

Upper-level ancestors (7 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.498gdcGDC7616-MIB
Numeric OIDNameModule
1.3.6.1.4.1.498.6dsx1GDCDSX1-MIB
1.3.6.1.4.1.498.6.1gdcDsx1SystemGDCDSX1-MIB
1.3.6.1.4.1.498.6.1.3gdcDsx1ConfigurationGDCDSX1-MIB
1.3.6.1.4.1.498.6.1.3.1gdcDsx1ConfigTableGDCDSX1-MIB
1.3.6.1.4.1.498.6.1.3.1.1gdcDsx1ConfigEntryGDCDSX1-MIB
1.3.6.1.4.1.498.6.1.3.1.1.5gdcDsx1AdminLineBuildoutGDCDSX1-MIB