GDCDSX1-MIB :: gdcDsx1ANSIcontrolledSlips

MIB Reference — IPNetwork Monitor · Updated September 14, 2026

All MIBsGDCDSX1-MIBgdcDsx1ANSIcontrolledSlips

gdcDsx1ANSIcontrolledSlips

Module: GDCDSX1-MIB

OID (symbolic): GDCDSX1-MIB::gdcDsx1ANSIcontrolledSlips

OID (numeric): 1.3.6.1.4.1.498.6.1.5.1.1.8

Node type: OBJECT-TYPE

Type: INTEGER

Access: read-only

Description: Identifies whether or not any controlled slips were detected in the interval which this entry represents.

What is gdcDsx1ANSIcontrolledSlips?

This flags whether any controlled slips (clock synchronization adjustments) occurred during this one-second interval, which can indicate a clocking mismatch between this unit and the far end.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.498.6.1.5.1.1.8
snmpwalk -v2c -c public <target> GDCDSX1-MIB::gdcDsx1ANSIcontrolledSlips

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.498.6.1.5.1.1.8.1
snmpget -v2c -c public <target> GDCDSX1-MIB::gdcDsx1ANSIcontrolledSlips.1

Start monitoring General DataComm (GDC) DSX-1 unit (legacy) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the GDCDSX1-MIB::gdcDsx1ANSIcontrolledSlips OID value, configure state conditions and alerts, and monitor any General DataComm (GDC) DSX-1 unit (legacy) from a single console.

OID Breakdown

Upper-level ancestors (7 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.498gdcGDC7616-MIB
Numeric OIDNameModule
1.3.6.1.4.1.498.6dsx1GDCDSX1-MIB
1.3.6.1.4.1.498.6.1gdcDsx1SystemGDCDSX1-MIB
1.3.6.1.4.1.498.6.1.5gdcDsx1PerformanceGDCDSX1-MIB
1.3.6.1.4.1.498.6.1.5.1gdcDsx1ANSIperfTableGDCDSX1-MIB
1.3.6.1.4.1.498.6.1.5.1.1gdcDsx1ANSIperfEntryGDCDSX1-MIB
1.3.6.1.4.1.498.6.1.5.1.1.8gdcDsx1ANSIcontrolledSlipsGDCDSX1-MIB