GDC7616-MIB :: uas7616LocalUAS

MIB Reference — IPNetwork Monitor · Updated September 14, 2026

All MIBsGDC7616-MIBuas7616LocalUAS

uas7616LocalUAS

Module: GDC7616-MIB

OID (symbolic): GDC7616-MIB::uas7616LocalUAS

OID (numeric): 1.3.6.1.4.1.498.12.4.14.1.3

Node type: OBJECT-TYPE

Type: INTEGER

Access: read-write

Description: Disables or enables the UAS alarm on the Major buss or Minor buss.

What is uas7616LocalUAS?

This read-write setting (disabled, enabledMajor, enabledMinor) controls whether Unavailable Seconds on a loop drive the shelf's backplane Major or Minor alarm bus. An admin sets this to enabledMajor on business-critical circuits so sustained unavailability lights the shelf's major-alarm indicator.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.498.12.4.14.1.3
snmpwalk -v2c -c public <target> GDC7616-MIB::uas7616LocalUAS

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.498.12.4.14.1.3.1
snmpget -v2c -c public <target> GDC7616-MIB::uas7616LocalUAS.1

Set instance 1 (SNMPv2c):

snmpset -v2c -c private <target> 1.3.6.1.4.1.498.12.4.14.1.3.1 i <value>

Start monitoring General DataComm (GDC) UAS 7616 multiplexer/access chassis with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the GDC7616-MIB::uas7616LocalUAS OID value, configure state conditions and alerts, and monitor any General DataComm (GDC) UAS 7616 multiplexer/access chassis from a single console.

OID Breakdown

Upper-level ancestors (6 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
Numeric OIDNameModule
1.3.6.1.4.1.498gdcGDC7616-MIB
1.3.6.1.4.1.498.12bql2GDC7616-MIB
1.3.6.1.4.1.498.12.4uas7616GDC7616-MIB
1.3.6.1.4.1.498.12.4.14uas7616LocalAlarmConfigTableGDC7616-MIB
1.3.6.1.4.1.498.12.4.14.1uas7616LocalAlarmConfigEntryGDC7616-MIB
1.3.6.1.4.1.498.12.4.14.1.3uas7616LocalUASGDC7616-MIB