All MIBs › GDC7616-MIB › uas7616LocalOutOfSync
uas7616LocalOutOfSync
Module: GDC7616-MIB
OID (symbolic): GDC7616-MIB::uas7616LocalOutOfSync
OID (numeric): 1.3.6.1.4.1.498.12.4.14.1.6
Node type: OBJECT-TYPE
Type: INTEGER
Access: read-write
Description: Disables or enables the Out of Sync alarm on the Major buss or Minor buss.
What is uas7616LocalOutOfSync?
This read-write setting (disabled, enabledMajor, enabledMinor) controls whether an Out of Sync condition on a loop drives the shelf's backplane Major or Minor alarm bus. Since loss of synchronization typically means the loop has dropped entirely, admins commonly wire this to the Major bus.
Examples
Walk all instances (SNMPv2c):
snmpwalk -v2c -c public <target> 1.3.6.1.4.1.498.12.4.14.1.6 snmpwalk -v2c -c public <target> GDC7616-MIB::uas7616LocalOutOfSync
Get a specific instance (index 1):
snmpget -v2c -c public <target> 1.3.6.1.4.1.498.12.4.14.1.6.1 snmpget -v2c -c public <target> GDC7616-MIB::uas7616LocalOutOfSync.1
Set instance 1 (SNMPv2c):
snmpset -v2c -c private <target> 1.3.6.1.4.1.498.12.4.14.1.6.1 i <value>
Start monitoring General DataComm (GDC) UAS 7616 multiplexer/access chassis with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the GDC7616-MIB::uas7616LocalOutOfSync OID value, configure state conditions and alerts, and monitor any General DataComm (GDC) UAS 7616 multiplexer/access chassis from a single console.
OID Breakdown
Upper-level ancestors (6 from the standard OID tree / other modules)
| Numeric OID | Name | Module |
|---|---|---|
| 1 | iso | LANART-AGENT |
| 1.3 | org | AirPair-MIB |
| 1.3.6 | dod | AirPair-MIB |
| 1.3.6.1 | internet | AirPair-MIB |
| 1.3.6.1.4 | private | AirPair-MIB |
| 1.3.6.1.4.1 | enterprises | AirPair-MIB |
| Numeric OID | Name | Module |
|---|---|---|
| 1.3.6.1.4.1.498 | gdc | GDC7616-MIB |
| 1.3.6.1.4.1.498.12 | bql2 | GDC7616-MIB |
| 1.3.6.1.4.1.498.12.4 | uas7616 | GDC7616-MIB |
| 1.3.6.1.4.1.498.12.4.14 | uas7616LocalAlarmConfigTable | GDC7616-MIB |
| 1.3.6.1.4.1.498.12.4.14.1 | uas7616LocalAlarmConfigEntry | GDC7616-MIB |
| 1.3.6.1.4.1.498.12.4.14.1.6 | uas7616LocalOutOfSync | GDC7616-MIB |