All MIBs › GDC7616-MIB › uas7616LocalLossOfClock
uas7616LocalLossOfClock
Module: GDC7616-MIB
OID (symbolic): GDC7616-MIB::uas7616LocalLossOfClock
OID (numeric): 1.3.6.1.4.1.498.12.4.14.1.2
Node type: OBJECT-TYPE
Type: INTEGER
Access: read-write
Description: Disables or enables the Loss of Clock alarm on the Major buss or Minor buss.
What is uas7616LocalLossOfClock?
This read-write setting (disabled, enabledMajor, enabledMinor) controls whether a Loss of Clock condition on a loop drives the shelf's backplane Major alarm bus, Minor alarm bus, or neither. An admin enables this on the loop carrying the shelf's primary timing source, since losing clock there is usually service-critical.
Examples
Walk all instances (SNMPv2c):
snmpwalk -v2c -c public <target> 1.3.6.1.4.1.498.12.4.14.1.2 snmpwalk -v2c -c public <target> GDC7616-MIB::uas7616LocalLossOfClock
Get a specific instance (index 1):
snmpget -v2c -c public <target> 1.3.6.1.4.1.498.12.4.14.1.2.1 snmpget -v2c -c public <target> GDC7616-MIB::uas7616LocalLossOfClock.1
Set instance 1 (SNMPv2c):
snmpset -v2c -c private <target> 1.3.6.1.4.1.498.12.4.14.1.2.1 i <value>
SNMPv3 example:
snmpget -v3 -l authPriv -u snmpv3-user -a SHA -A "AuthPassword1" -x AES -X "PrivPassword1" <target> uas7616LocalLossOfClock.1
Start monitoring General DataComm (GDC) UAS 7616 multiplexer/access chassis with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the GDC7616-MIB::uas7616LocalLossOfClock OID value, configure state conditions and alerts, and monitor any General DataComm (GDC) UAS 7616 multiplexer/access chassis from a single console.
OID Breakdown
Upper-level ancestors (6 from the standard OID tree / other modules)
| Numeric OID | Name | Module |
|---|---|---|
| 1 | iso | LANART-AGENT |
| 1.3 | org | AirPair-MIB |
| 1.3.6 | dod | AirPair-MIB |
| 1.3.6.1 | internet | AirPair-MIB |
| 1.3.6.1.4 | private | AirPair-MIB |
| 1.3.6.1.4.1 | enterprises | AirPair-MIB |
| Numeric OID | Name | Module |
|---|---|---|
| 1.3.6.1.4.1.498 | gdc | GDC7616-MIB |
| 1.3.6.1.4.1.498.12 | bql2 | GDC7616-MIB |
| 1.3.6.1.4.1.498.12.4 | uas7616 | GDC7616-MIB |
| 1.3.6.1.4.1.498.12.4.14 | uas7616LocalAlarmConfigTable | GDC7616-MIB |
| 1.3.6.1.4.1.498.12.4.14.1 | uas7616LocalAlarmConfigEntry | GDC7616-MIB |
| 1.3.6.1.4.1.498.12.4.14.1.2 | uas7616LocalLossOfClock | GDC7616-MIB |