GDC7616-MIB :: uas7616LocalLossOfClock

MIB Reference — IPNetwork Monitor · Updated September 14, 2026

All MIBsGDC7616-MIBuas7616LocalLossOfClock

uas7616LocalLossOfClock

Module: GDC7616-MIB

OID (symbolic): GDC7616-MIB::uas7616LocalLossOfClock

OID (numeric): 1.3.6.1.4.1.498.12.4.14.1.2

Node type: OBJECT-TYPE

Type: INTEGER

Access: read-write

Description: Disables or enables the Loss of Clock alarm on the Major buss or Minor buss.

What is uas7616LocalLossOfClock?

This read-write setting (disabled, enabledMajor, enabledMinor) controls whether a Loss of Clock condition on a loop drives the shelf's backplane Major alarm bus, Minor alarm bus, or neither. An admin enables this on the loop carrying the shelf's primary timing source, since losing clock there is usually service-critical.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.498.12.4.14.1.2
snmpwalk -v2c -c public <target> GDC7616-MIB::uas7616LocalLossOfClock

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.498.12.4.14.1.2.1
snmpget -v2c -c public <target> GDC7616-MIB::uas7616LocalLossOfClock.1

Set instance 1 (SNMPv2c):

snmpset -v2c -c private <target> 1.3.6.1.4.1.498.12.4.14.1.2.1 i <value>

SNMPv3 example:

snmpget -v3 -l authPriv -u snmpv3-user -a SHA -A "AuthPassword1" -x AES -X "PrivPassword1" <target> uas7616LocalLossOfClock.1

Start monitoring General DataComm (GDC) UAS 7616 multiplexer/access chassis with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the GDC7616-MIB::uas7616LocalLossOfClock OID value, configure state conditions and alerts, and monitor any General DataComm (GDC) UAS 7616 multiplexer/access chassis from a single console.

OID Breakdown

Upper-level ancestors (6 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
Numeric OIDNameModule
1.3.6.1.4.1.498gdcGDC7616-MIB
1.3.6.1.4.1.498.12bql2GDC7616-MIB
1.3.6.1.4.1.498.12.4uas7616GDC7616-MIB
1.3.6.1.4.1.498.12.4.14uas7616LocalAlarmConfigTableGDC7616-MIB
1.3.6.1.4.1.498.12.4.14.1uas7616LocalAlarmConfigEntryGDC7616-MIB
1.3.6.1.4.1.498.12.4.14.1.2uas7616LocalLossOfClockGDC7616-MIB