GDC-SC800T3-MIB :: sc800t3TestAllLeds

MIB Reference — IPNetwork Monitor · Updated September 14, 2026

All MIBsGDC-SC800T3-MIBsc800t3TestAllLeds

sc800t3TestAllLeds

Module: GDC-SC800T3-MIB

OID (symbolic): GDC-SC800T3-MIB::sc800t3TestAllLeds

OID (numeric): 1.3.6.1.4.1.498.19.1.4.1.1.9

Node type: OBJECT-TYPE

Type: INTEGER

Access: read-write

Description: This variable is used to test the front panel leds and individual segments of the display. A one (1) will turn all leds and display segments on. They will remain on until a two (2) is set or the card is rebooted

What is sc800t3TestAllLeds?

Setting this to allLedsON(1) lights every front-panel LED and display segment for a lamp test; they stay lit until set back to allLedsOFF(2) or the card reboots. Admins use this during installation or field service to visually verify no LED segments have failed.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.498.19.1.4.1.1.9
snmpwalk -v2c -c public <target> GDC-SC800T3-MIB::sc800t3TestAllLeds

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.498.19.1.4.1.1.9.1
snmpget -v2c -c public <target> GDC-SC800T3-MIB::sc800t3TestAllLeds.1

Set instance 1 (SNMPv2c):

snmpset -v2c -c private <target> 1.3.6.1.4.1.498.19.1.4.1.1.9.1 i <value>

Start monitoring General DataComm (GDC) SC800 T3 channel-service unit with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the GDC-SC800T3-MIB::sc800t3TestAllLeds OID value, configure state conditions and alerts, and monitor any General DataComm (GDC) SC800 T3 channel-service unit from a single console.

OID Breakdown

Upper-level ancestors (7 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.498gdcGDC7616-MIB
Numeric OIDNameModule
1.3.6.1.4.1.498.19ds3GDC-SC800T3-MIB
1.3.6.1.4.1.498.19.1sc800t3GDC-SC800T3-MIB
1.3.6.1.4.1.498.19.1.4sc800t3MaintenanceGDC-SC800T3-MIB
1.3.6.1.4.1.498.19.1.4.1sc800t3MaintenanceTableGDC-SC800T3-MIB
1.3.6.1.4.1.498.19.1.4.1.1sc800t3MaintenanceEntryGDC-SC800T3-MIB
1.3.6.1.4.1.498.19.1.4.1.1.9sc800t3TestAllLedsGDC-SC800T3-MIB