-- **************************************************************************** -- sc800T3.mib -- **************************************************************************** -- Copyright 1998 General DataComm Inc., All Rights Reserved. -- -- Reproduction of this document is authorized on condition that the -- foregoing copyright notice is included. This General DataComm, GDC, -- SNMP Management Information Base Specification embodies GDCs' -- confidential and proprietary intellectual property. GDC retains all -- title and ownership in the Specification, including any revisions. -- -- It is GDCs intent to encourage the widespread use of this Specification -- in connection with the management of GDC's products. GDC grants vendors, -- end-users, and other interested parties a non-exclusive license to use -- this Specification in connection with the management of GDC's products. -- -- This Specification is supplied "AS IS," and GDC makes no warranty, -- either expressed or implied, as to the use operation, condition, or -- performance of the Specification. -- This MIB module uses the extended OBJECT-TYPE macro as -- defined in RFC 1212. -- Note: All rows in all tables defined within this MIB module are -- virtual. They can neither be created or deleted by management -- operations. -- **************************************************************************** -- revision History -- **************************************************************************** -- Version Date Name -- 1.00A 19-May-98 J. Costa Initial Revision -- 1.00B 19-Jan-99 C. Amorossi 1) Remove alarm sc800t3ReceivedYellow -- 2) Add maskable alarms sc800t3ES, -- sc800t3SES, sc800t3SAS, sc800t3UAS, -- sc8003ESline, sc800t3RAI -- 3) Add windows/thresholds for -- sc800t3ES, sc800t3SES, sc800t3SAS, -- sc800t3UAS, sc800t3ESline -- 4) Remove windows/thresholds for -- sc800t3LossOfSignal, sc800t3AIS, -- sc800t3OutOfFrame -- 5) Update comment for alarm scan -- 6) Change description of -- sc800t3CurrentNearEndStat, -- sc800t3CurrentFarEndStat, -- sc800t3NearEndIntervalStats, -- sc800t3FarEndIntervalStats -- 7) Change number of valid intervals -- from 96 to 31 -- 8) Added sc800t3NetworkIdleStatus and -- sc800t3NetworkTransmitIdleStatus to -- sc800t3NetworkConfigTable -- 9) Change Total Statistics to Current -- Day Statistics -- 10)Added Previous Day Statistics -- 11)Added enums to sc800t3ResetStatistics -- 1.00C 06-Apr-99 J. Bassett 1) Added End to end w/selftest -- 2) Added Ses BER threshold -- 3) Commented out sc800t3DteStat - not supported -- 1.00D 02-Jun-99 J. Bassett 1) Added thresGT100000 and thresGT1000000 to -- sc800t3AlarmCountThreshold -- 2) Added sc800t3NearEndResetStats, sc800t3FarEndResetStats, -- sc800t3NearEndStatLastInitial, sc800t3FarEndStatLastInitial; -- removed sc800t3ResetStatistics -- 3) Removed Tx & Rx Invert and External Txmt Clk -- 4) Removed INS, CV, AIS, OOF, NS, and TM/ALM leds; removed -- TM switch -- 5) Added NTWK, TM, ALM leds -- 6) Removed front panel test condition; removed excess zeros -- alarm mask -- 7) Removed exczeros, excess error rate and front panel test -- 8) Expanded bit error counter to 16 bits -- 9) Added local alarm masks -- 10)Renumbered alarm OIDs -- 11)Added remote status to sc800t3DiagTestResults -- 12)Removed sc800t3NetworkLineCoding, -- sc800t3ChannelRate -- 13)Changed names of channel config entries; -- added DTELoopTimeout; corrected description of -- sc800t3ChannelDTEtest -- 14)Added sc800t3InbandLoopback, sc800t3DTELoopTimeout -- 15)Removed sc800t3DiagT3SelfTestPattern -- 1.00E 19-Jul-99 J. Bassett 1) Changed TxClkSrc definitions -- 2) Added sc800t3EraseFlash -- 1.00F 01-Sep-99 J. Bassett Reordered alarm oids so that the following order is -- observed: non maskable, maskable, and thresh/windows -- 1.00G 07-Sep-99 J. Bassett 1) Added sc800t3POSTFail to alarm table -- 2) Added objects for previous near and far end 15 min -- statistics - sc800t3PreviousNearEndStat, -- sc800t3PreviousFarEndStat -- -- **************************************************************************** -- **************************************************************************** -- mib definitions begin -- **************************************************************************** GDC-SC800T3-MIB DEFINITIONS ::= BEGIN IMPORTS OBJECT-TYPE FROM RFC-1212 DisplayString FROM RFC1213-MIB gdc FROM GDCCMN-MIB SCinstance FROM GDCMACRO-MIB; ds3 OBJECT IDENTIFIER ::= { gdc 19 } sc800t3 OBJECT IDENTIFIER ::= { ds3 1 } sc800t3Version OBJECT IDENTIFIER ::= { sc800t3 1 } sc800t3Configuration OBJECT IDENTIFIER ::= { sc800t3 2 } sc800t3Diagnostics OBJECT IDENTIFIER ::= { sc800t3 3 } sc800t3Maintenance OBJECT IDENTIFIER ::= { sc800t3 4 } sc800t3Alarms OBJECT IDENTIFIER ::= { sc800t3 5 } sc800t3Performance OBJECT IDENTIFIER ::= { sc800t3 6 } sc800t3AlarmConfig OBJECT IDENTIFIER ::= { sc800t3 7 } sc800t3LocalAlarms OBJECT IDENTIFIER ::= { sc800t3 8 } --**************************************************************************** -- SCinstance is defined as the addressing/indexing method of accessing -- table objects in this MIB. The SCinstance represents the SpectraComm -- shelf Slot, Line, Drop and interface address. -- Represented as SLDi, (Slot, Line, Drop, interface). -- -- For the sc800t3: -- -- Byte Range (dec.) Identifies -- ---- ------------ ---------- -- [S]lot 1 - 32 Physical Slot -- 1-16: 1st Shelf -- 17-32: 2nd Shelf -- -- [L]ine 1 -- -- [D]rop 0 -- -- [i]nterface 0 0: Unit -- -- **************************************************************************** sc800t3MIBversion OBJECT-TYPE SYNTAX DisplayString (SIZE (5)) ACCESS read-only STATUS mandatory DESCRIPTION "Identifies the version of the MIB. The format of the version is x.yzT, where 'x' identifies the major revision number, 'y' identifies the minor revision number, 'z' identifies the typographical revision, and T identifies the test revision. Upon formal release, no designation for the test revision will be present. Acceptable values for the individual revision components are as follows: x: 1 - 9, y: 0 - 9, z: 0 - 9, T: A - Z" ::= { sc800t3Version 1 } -- **************************************************************************** -- Version Table -- **************************************************************************** sc800t3VersionTable OBJECT-TYPE SYNTAX SEQUENCE OF Sc800t3VersionEntry ACCESS not-accessible STATUS mandatory DESCRIPTION " " ::= { sc800t3Version 2 } sc800t3VersionEntry OBJECT-TYPE SYNTAX Sc800t3VersionEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "An entry in the GDC SC800T3 Version Table." INDEX { sc800t3VersionIndex } ::= { sc800t3VersionTable 1 } Sc800t3VersionEntry ::= SEQUENCE { sc800t3VersionIndex SCinstance, sc800t3ActiveFirmwareRev DisplayString, sc800t3StandbyFirmwareRev DisplayString, sc800t3StoredFirmwareStatus INTEGER, sc800t3SwitchActiveFirmware INTEGER, sc800t3DownloadingMode INTEGER, sc800t3EraseFlash INTEGER } sc800t3VersionIndex OBJECT-TYPE SYNTAX SCinstance ACCESS read-only STATUS mandatory DESCRIPTION "Integer value which uniquely identifies the SC800T3 to which this entry is applicable. SCinstance is defined to be SLDi where: S (byte value) - physical shelf slot location (01-32) L (byte value) - line number (01) D (byte value) - drop number (00) i (byte value) - interface number (00)" ::= { sc800t3VersionEntry 1 } sc800t3ActiveFirmwareRev OBJECT-TYPE SYNTAX DisplayString (SIZE(8)) ACCESS read-only STATUS mandatory DESCRIPTION "The version number of the firmware currently executing. The format is MM.NN.BB where: MM: Major Revision (0-99) NN: Minor Revision (0-99) BB: Bug Fix Revision (0-99)" ::= { sc800t3VersionEntry 2 } sc800t3StandbyFirmwareRev OBJECT-TYPE SYNTAX DisplayString (SIZE(8)) ACCESS read-only STATUS mandatory DESCRIPTION "The version number of the firmware stored (in a compressed format) but not currently executing. MM: Major Revision (0-99) NN: Minor Revision (0-99) BB: Bug Fix Revision (0-99) " ::= { sc800t3VersionEntry 3 } sc800t3StoredFirmwareStatus OBJECT-TYPE SYNTAX INTEGER { statBlank(1), statDownLoading(2), statOK(3), statCheckSumBad(4), statUnZipping(5), statBadUnZip(6), statDownloadAborted(7) } ACCESS read-only STATUS mandatory DESCRIPTION "This object represents the state of the Non-Active or Stored firmware: statBlank(1) Factory Default statDownLoading(2) In process of downloading firmware statOK(3) Zipped version checksum succesful (OK to switch) (can set sc800t3SwitchActive to switchActive(2)) statCheckSumBad(4) Failed checksum after download statUnZipping(5) In process of uncompressing into active area statBadUnZip(6) Failed last uncompress statDownloadAborted(7) Download aborted by user" ::= { sc800t3VersionEntry 4 } sc800t3SwitchActiveFirmware OBJECT-TYPE SYNTAX INTEGER { switchNorm(1), -- Read only switchActive(2) -- Write only } ACCESS read-write STATUS mandatory DESCRIPTION "This object is used to switch the active executing firmware from the version in sc800t3ActiveRev to the version in sc800t3StoredRev. When a switchActive(2) is set (write only) the element will: 1) reboot 2) uncompress stored code into active area 3) perform checksum on active area 4) Set sc800t3StoredStatus object to indicate results 5) If succesfull: update sc800t3ActiveFirmwareRev and sc800t3StoredFirmwareRev and begin executing If failed: replace active area with previous revision The switchNorm(1) enumeration will always be read. Setting switchActive(2) when the sc800t3StoredStatus is not statOK(3) will result in an error. " ::= { sc800t3VersionEntry 5 } sc800t3DownloadingMode OBJECT-TYPE SYNTAX INTEGER { disableAll(1), enableAndWait(2), enableAndSwitch(3) } ACCESS read-write STATUS mandatory DESCRIPTION "This object is used to configure the download mode: disableAll(1) Prevents any firmware downloading to SC800T3 enableAndWait(2) Allows downloading zipped code to be stored only! enableAndSwitch(3) Allows downloading and then unzips and begins executing the new code" ::= { sc800t3VersionEntry 6 } sc800t3EraseFlash OBJECT-TYPE SYNTAX INTEGER { normal(1), -- read-only erase(2) -- write-only } ACCESS read-write STATUS mandatory DESCRIPTION "A set of this object to erase(2) will erase the application stored in flash. After setting this object, there should be a delay of at least 2 minutes before downloading the unit." ::= { sc800t3VersionEntry 7} -- **************************************************************************** -- Channel Configuration table -- **************************************************************************** sc800t3ChannelConfigTable OBJECT-TYPE SYNTAX SEQUENCE OF Sc800t3ChannelConfigEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "The GDC SC800T3 Channel Configuration table." ::= { sc800t3Configuration 1 } sc800t3ChannelConfigEntry OBJECT-TYPE SYNTAX Sc800t3ChannelConfigEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "The sc800t3 Channel Configuration table entry." INDEX { sc800t3ChannelConfigIndex } ::= { sc800t3ChannelConfigTable 1 } Sc800t3ChannelConfigEntry ::= SEQUENCE { sc800t3ChannelConfigIndex SCinstance, sc800t3ForcedDCE INTEGER, sc800t3ChannelDTEtest INTEGER, sc800t3DTELoopTimeout INTEGER } sc800t3ChannelConfigIndex OBJECT-TYPE SYNTAX SCinstance ACCESS read-only STATUS mandatory DESCRIPTION "Integer value which uniquely identifies the SC800T3 to which this entry is applicable. SCinstance is defined to be SLDi where: S (byte value) - physical shelf slot location (01-32) L (byte value) - line number (01) D (byte value) - drop number (00) i (byte value) - interface number (00)" ::= { sc800t3ChannelConfigEntry 1 } sc800t3ForcedDCE OBJECT-TYPE SYNTAX INTEGER { followsDte(1), -- local DCE follows DTE forcedOn(2) -- local DCE forced on } ACCESS read-write STATUS mandatory DESCRIPTION "Controls the operation of Data Communications Equipment (DCE) signal. The value followsDte(1) indicates that the channel's DCE follows Data Terminal Equipment (DTE) ready. The value forcedOn(2) indicates that DCE is forced on." ::= { sc800t3ChannelConfigEntry 2 } sc800t3ChannelDTEtest OBJECT-TYPE SYNTAX INTEGER { disabled(1), -- DTE test disabled enabled(2) -- DTE test enabled } ACCESS read-write STATUS mandatory DESCRIPTION "DTE interface supporting loop A and loop B tests. See ANSI TIA/EIA-613-1993 specification for details on encoding of inter changes." ::= { sc800t3ChannelConfigEntry 3 } sc800t3DTELoopTimeout OBJECT-TYPE SYNTAX INTEGER { disabled(1), -- DTE loop time out disabled enabled(2) -- DTE loop time out enabled } ACCESS read-write STATUS mandatory DESCRIPTION "Enables/disables DTE loop time out." ::= { sc800t3ChannelConfigEntry 4 } -- **************************************************************************** -- Network Configuration table -- **************************************************************************** sc800t3NetworkConfigTable OBJECT-TYPE SYNTAX SEQUENCE OF Sc800t3NetworkConfigEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "The GDC SC800T3 Network Configuration table." ::= { sc800t3Configuration 2 } sc800t3NetworkConfigEntry OBJECT-TYPE SYNTAX Sc800t3NetworkConfigEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "The sc800t3 Network Configuration table entry." INDEX { sc800t3NetworkConfigIndex } ::= { sc800t3NetworkConfigTable 1 } Sc800t3NetworkConfigEntry ::= SEQUENCE { sc800t3NetworkConfigIndex SCinstance, sc800t3NetworkFrameType INTEGER, sc800t3NetworkTransmitClockSource INTEGER, sc800t3NetworkAISLoopdown INTEGER, sc800t3NetworkLineType INTEGER, sc800t3NetworkIdleStatus INTEGER, sc800t3NetworkTransmitIdleStatus INTEGER, sc800t3NetworkSesBERThreshold INTEGER, sc800t3InbandLoopback INTEGER } sc800t3NetworkConfigIndex OBJECT-TYPE SYNTAX SCinstance ACCESS read-only STATUS mandatory DESCRIPTION "Integer value which uniquely identifies the SC800T3 to which this entry is applicable. SCinstance is defined to be SLDi where: S (byte value) - physical shelf slot location (01-32) L (byte value) - line number (01) D (byte value) - drop number (00) i (byte value) - interface number (00)" ::= { sc800t3NetworkConfigEntry 1 } sc800t3NetworkFrameType OBJECT-TYPE SYNTAX INTEGER { m13(1), -- M-13 framing type cbitParity(2) -- C-bit parity framing } ACCESS read-write STATUS mandatory DESCRIPTION "Is the framing type of the network interface. Setting the value of the object to m13(1) configures the network interface to M-13 framing. Setting the value of this object to cbitParity configures the network interface 20 C-bit parity framing" ::= { sc800t3NetworkConfigEntry 2 } sc800t3NetworkTransmitClockSource OBJECT-TYPE SYNTAX INTEGER { internal(1), -- internal transmit clock source receive(2) -- network transmit clock source } ACCESS read-write STATUS mandatory DESCRIPTION "The DSU transmit clock source option. This is the selection for the transmitter timing clock source." ::= { sc800t3NetworkConfigEntry 3 } sc800t3NetworkAISLoopdown OBJECT-TYPE SYNTAX INTEGER (4..60) -- disable, 5..60 seconds ACCESS read-write STATUS mandatory DESCRIPTION "The time in seconds when receiving a continuous AIS signal before a remotely initiated loopback is terminated. When this object has the value 4, then there is no time limit and the loop must be terminated by remotely issued in-band loopdown codes. When the object has a value between 5 and 60, then this is time in seconds of continuous AIS signal before the loopback is terminated." ::= { sc800t3NetworkConfigEntry 4 } sc800t3NetworkLineType OBJECT-TYPE SYNTAX INTEGER { longCable(1), -- 50 - 450 ft, DS-3 mode shortCable(2) -- 0 to 100 ft, DSX-3 } ACCESS read-write STATUS mandatory DESCRIPTION "The operating mode of the interface. Setting the value of this object to longCable(1) configures the interface as standard DS-3. Setting the value of this object to shortCable(2) configures the interface to operate as a standard cross-connect DSX-3." ::= { sc800t3NetworkConfigEntry 5 } sc800t3NetworkIdleStatus OBJECT-TYPE SYNTAX INTEGER { notReceived(1), received(2) } ACCESS read-only STATUS mandatory DESCRIPTION "Returns a value of received(2) when the sc800t3 receives a DS3 idle from the network." ::= { sc800t3NetworkConfigEntry 6 } sc800t3NetworkTransmitIdleStatus OBJECT-TYPE SYNTAX INTEGER { inactive(1), active(2) } ACCESS read-write STATUS mandatory DESCRIPTION "When set to active(2), the sc800t3 will transmit a DS3 idle signal to the network." ::= { sc800t3NetworkConfigEntry 7 } sc800t3NetworkSesBERThreshold OBJECT-TYPE SYNTAX INTEGER { thresone(1), -- 1X10^-6 (44) thresseven(2) -- 7.5X10^-5 (2444) } ACCESS read-write STATUS mandatory DESCRIPTION "When set to thresone(1), the SES BER threshold will be set to 1X10^-6 and when it is set to thresseven(2), it will be set to 7.5X10^-5." ::= { sc800t3NetworkConfigEntry 8 } sc800t3InbandLoopback OBJECT-TYPE SYNTAX INTEGER { disabled(1), -- Inband loop back disabled enabled(2) -- Inband loop back enabled } ACCESS read-write STATUS mandatory DESCRIPTION "Enables/disables the inband loop back." ::= { sc800t3NetworkConfigEntry 9 } -- **************************************************************************** -- Diagnostics table -- **************************************************************************** sc800t3DiagTable OBJECT-TYPE SYNTAX SEQUENCE OF Sc800t3DiagEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "The SC800T3 Diagnostics table." ::= { sc800t3Diagnostics 1 } sc800t3DiagEntry OBJECT-TYPE SYNTAX Sc800t3DiagEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "The SNMPSC800T3 Diagnostics table entry." INDEX { sc800t3DiagIndex } ::= { sc800t3DiagTable 1 } Sc800t3DiagEntry ::= SEQUENCE { sc800t3DiagIndex SCinstance, sc800t3DiagTestDuration INTEGER, sc800t3InsertBitError INTEGER, sc800t3DiagT3Test INTEGER, sc800t3DiagTestResults OCTET STRING, sc800t3DiagResetTestResults INTEGER } sc800t3DiagIndex OBJECT-TYPE SYNTAX SCinstance ACCESS read-only STATUS mandatory DESCRIPTION "Integer value which uniquely identifies the SC800T3 to which this entry is applicable. SCinstance is defined to be SLDi where: S (byte value) - physical shelf slot location (01-32) L (byte value) - line number (01) D (byte value) - drop number (00) i (byte value) - interface number (00)" ::= { sc800t3DiagEntry 1 } sc800t3DiagTestDuration OBJECT-TYPE SYNTAX INTEGER { testTime30Secs(1), testTime1Min(2), testTime2Mins(3), testTime3Mins(4), testTime4Mins(5), testTime5Mins(6), testTime6Mins(7), testTime7Mins(8), testTime8Mins(9), testTime9Mins(10), testTime10Mins(11), testTime15Mins(12), testTime20Mins(13), testTime25Mins(14), testTime30Mins(15), testTimeInfinite(16) } ACCESS read-write STATUS mandatory DESCRIPTION "Selects the duration to run a diagnostic test." ::= { sc800t3DiagEntry 2 } sc800t3InsertBitError OBJECT-TYPE SYNTAX INTEGER { insertBitErrorNorm(1), -- Read Only insertOneBitError(2) } ACCESS read-write STATUS mandatory DESCRIPTION "A set of 2 will insert one bit error for test. Management may only write a 2. A 1 will always be read." ::= { sc800t3DiagEntry 3 } sc800t3DiagT3Test OBJECT-TYPE SYNTAX INTEGER { t3NoTest(1), -- no test active t3LineLoopback(2), -- towards Network t3PayLoadLoopback(3), -- towards Network t3LocalLoopback(4), -- towards DTE interface t3LocalLoopbackST(5), -- uses internal gen/checker t3DTELoopback(6), -- towards DTE interface t3RemoteLineLoopback(7), -- only in C-bit parity mode t3RemoteLineLoopbackST(8), -- only in C-bit parity mode t3RemotePayload(9), -- only in C-bit parity mode t3RemotePayloadST(10), -- only in C-bit parity mode t3EndToEndST(11) } ACCESS read-write STATUS mandatory DESCRIPTION "A set of 2-11 starts the specified test and a set of t3NoTest(1) stops the current running test. A get returns the current active test." ::= { sc800t3DiagEntry 4 } sc800t3DiagTestResults OBJECT-TYPE SYNTAX OCTET STRING (SIZE(3)) ACCESS read-only STATUS mandatory DESCRIPTION "Returns a the folowing bytes. Octet 1 bit 7 - F/U bit 6 - 1: Test complete bit 5 - 1: Test aborted bit 4 - F/U bit 3 - remote status 0: inactive 1: active bit 2 - 1: Bit errors over range bit 1 - Bit Errors bit 0 - Bit Errors Octet 2 bit 7 - F/U bit 6 - 2^13 bit 5 - 2^12 bit 4 - 2^11 bit 3 - 2^10 bit 2 - 2^9 Bit Error Count bit 1 - 2^8 bit 0 - 2^7 Octet 3 bit 7 - F/U bit 6 - 2^6 bit 5 - 2^5 bit 4 - 2^4 bit 3 - 2^3 bit 2 - 2^2 bit 1 - 2^1 bit 0 - 2^0" ::= { sc800t3DiagEntry 5 } sc800t3DiagResetTestResults OBJECT-TYPE SYNTAX INTEGER { normal(1), -- read only resetTestResult(2) -- write only } ACCESS read-write STATUS mandatory DESCRIPTION "This object will clear the results register while running any test except for Network Delay. Starting a new test will automatically zero out the register. A normal(1) will always be read. Management will set a resetTestResult(2) to reset the test results. " ::= { sc800t3DiagEntry 6 } -- **************************************************************************** -- Maintenance Table -- **************************************************************************** sc800t3MaintenanceTable OBJECT-TYPE SYNTAX SEQUENCE OF Sc800t3MaintenanceEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "The table describes the maintenance functions for the sc800t3. " ::= { sc800t3Maintenance 1 } sc800t3MaintenanceEntry OBJECT-TYPE SYNTAX Sc800t3MaintenanceEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "An entry in the GDC maintenance Table" INDEX { sc800t3MaintenanceIndex } ::= { sc800t3MaintenanceTable 1 } Sc800t3MaintenanceEntry ::= SEQUENCE { sc800t3MaintenanceIndex SCinstance, sc800t3LedStatus OCTET STRING, sc800t3SoftReset INTEGER, sc800t3DefaultInit INTEGER, sc800t3ValidNearEndIntervals INTEGER, sc800t3ValidFarEndIntervals INTEGER, sc800t3ShelfType INTEGER, sc800t3TwinPackPowerSupply INTEGER, sc800t3TestAllLeds INTEGER, sc800t3NearEndResetStats INTEGER, sc800t3FarEndResetStats INTEGER, sc800t3NearEndStatLastInitial INTEGER, sc800t3FarEndStatLastInitial INTEGER } sc800t3MaintenanceIndex OBJECT-TYPE SYNTAX SCinstance ACCESS read-only STATUS mandatory DESCRIPTION "Integer value which uniquely identifies the SC800T3 to which this entry is applicable. SCinstance is defined to be SLDi where: S (byte value) - physical shelf slot location (01-32) L (byte value) - line number (01) D (byte value) - drop number (00) i (byte value) - interface number (00)" ::= { sc800t3MaintenanceEntry 1 } sc800t3LedStatus OBJECT-TYPE SYNTAX OCTET STRING (SIZE(3)) ACCESS read-only STATUS mandatory DESCRIPTION "Returns a bitwise snapshot of the front panel LED state and front panel switches. Octet 1 bit 7 - f/u bit 6 - NTWK 0:LED off 1:LED on bit 5 - TM 0:LED off 1:LED on bit 4 - ALM 0:LED off 1:LED on bit 3 - f/u bit 2 - f/u bit 1 - f/u bit 0 - f/u Octet 2 bit 7 - f/u bit 6 - f/u bit 5 - f/u bit 4 - f/u bit 3 - f/u bit 2 - f/u bit 1 - f/u bit 0 - f/u Octet 3 bit 7 - f/u bit 6 - f/u bit 5 - f/u bit 4 - f/u bit 3 - f/u bit 2 - f/u bit 1 - f/u bit 0 - f/u " ::= { sc800t3MaintenanceEntry 2 } sc800t3SoftReset OBJECT-TYPE SYNTAX INTEGER { norm(1), -- read-only reset(2) -- write-only } ACCESS read-write STATUS mandatory DESCRIPTION "Supports the action of soft resetting the unit. When this object is set to reset(1), then the unit performs a soft reset. The value norm will be returned when the reset is complete. The value of norm can not be set by management." ::= { sc800t3MaintenanceEntry 3 } sc800t3DefaultInit OBJECT-TYPE SYNTAX INTEGER { normal(1), -- read-only factoryDefault(2) -- write-only } ACCESS read-write STATUS mandatory DESCRIPTION "This is used to allow the NonVolatile Configuration to be set to a factory default state. When this value is set to factoryDefault, the unit will reset to the default configuration. The value of normal will be returned when the initialization is complete. The value normal can not be set by management." ::= { sc800t3MaintenanceEntry 4 } sc800t3ValidNearEndIntervals OBJECT-TYPE SYNTAX INTEGER (0..31) ACCESS read-only STATUS mandatory DESCRIPTION "The number of previous near end intervals for which valid data was collected. The value will be 31 unless the interface was brought on-line within the last 7.75 hours, in which case the value will be the number of complete 15 minute intervals since the interface has been online." ::= { sc800t3MaintenanceEntry 5 } sc800t3ValidFarEndIntervals OBJECT-TYPE SYNTAX INTEGER (0..31) ACCESS read-only STATUS mandatory DESCRIPTION "The number of previous far end intervals for which valid data was collected. The value will be 31 unless the interface was brought on-line within the last 7.75 hours, in which case the value will be the number of complete 15 minute intervals since the interface has been online." ::= { sc800t3MaintenanceEntry 6 } sc800t3ShelfType OBJECT-TYPE SYNTAX INTEGER { spectracomm(1), twinPack(2) } ACCESS read-only STATUS mandatory DESCRIPTION "Type of shelf the sc800t3 is located in." ::= { sc800t3MaintenanceEntry 7 } sc800t3TwinPackPowerSupply OBJECT-TYPE SYNTAX INTEGER { none(1), bottomOnly(2), topOnly(3), both(4) } ACCESS read-only STATUS mandatory DESCRIPTION "Power supplies currently installed in Twin Pack. When the sc800t3 is located in a Spectracomm shelf none(1) will always be returned." ::= { sc800t3MaintenanceEntry 8 } sc800t3TestAllLeds OBJECT-TYPE SYNTAX INTEGER { allLedsON(1), allLedsOFF(2) } ACCESS read-write STATUS mandatory DESCRIPTION "This variable is used to test the front panel leds and individual segments of the display. A one (1) will turn all leds and display segments on. They will remain on until a two (2) is set or the card is rebooted" ::= { sc800t3MaintenanceEntry 9 } sc800t3NearEndResetStats OBJECT-TYPE SYNTAX INTEGER { norm(1), reset(2) } ACCESS read-write STATUS mandatory DESCRIPTION "Supports the action of soft resetting the sc800t3ValidNearEndIntervals object. When this object is set to reset(2), then the unit will reset the sc800t3ValidNearEndIntervals object to zero. The value of norm(1) can not be set by management." ::= { sc800t3MaintenanceEntry 10 } sc800t3FarEndResetStats OBJECT-TYPE SYNTAX INTEGER { norm(1), reset(2) } ACCESS read-write STATUS mandatory DESCRIPTION "Supports the action of soft resetting the sc800t3ValidFarEndIntervals object. When this object is set to reset(2), then the unit will reset the sc800t3ValidFarEndIntervals object to zero. The value of norm(1) can not be set by management." ::= { sc800t3MaintenanceEntry 11 } sc800t3NearEndStatLastInitial OBJECT-TYPE SYNTAX INTEGER (1..2147483647) ACCESS read-only STATUS mandatory DESCRIPTION "Number of seconds from midnight Dec 31 1969 up until sc800t3ValidNearEndIntervals was last initialized to zero." ::= { sc800t3MaintenanceEntry 12 } sc800t3FarEndStatLastInitial OBJECT-TYPE SYNTAX INTEGER (1..2147483647) ACCESS read-only STATUS mandatory DESCRIPTION "Number of seconds from midnight Dec 31 1969 up until sc800t3ValidFarEndIntervals was last initialized to zero." ::= { sc800t3MaintenanceEntry 13 } -- **************************************************************************** -- Alarm Tables -- **************************************************************************** sc800t3NoResponse OBJECT IDENTIFIER ::= { sc800t3Alarms 1 } sc800t3DiagRxErrAlm OBJECT IDENTIFIER ::= { sc800t3Alarms 2 } sc800t3PowerUpAlm OBJECT IDENTIFIER ::= { sc800t3Alarms 3 } sc800t3POSTFail OBJECT IDENTIFIER ::= { sc800t3Alarms 4 } sc800t3UnsolicitedTest OBJECT IDENTIFIER ::= { sc800t3Alarms 5 } sc800t3ConfigChange OBJECT IDENTIFIER ::= { sc800t3Alarms 6 } sc800t3TimingLoss OBJECT IDENTIFIER ::= { sc800t3Alarms 7 } sc800t3LossOfSignal OBJECT IDENTIFIER ::= { sc800t3Alarms 8 } sc800t3OutOfFrame OBJECT IDENTIFIER ::= { sc800t3Alarms 9 } sc800t3AIS OBJECT IDENTIFIER ::= { sc800t3Alarms 10 } sc800t3DTEReadyLoss OBJECT IDENTIFIER ::= { sc800t3Alarms 11 } sc800t3DTETXCLKLoss OBJECT IDENTIFIER ::= { sc800t3Alarms 12 } sc800t3RXDNoTrans OBJECT IDENTIFIER ::= { sc800t3Alarms 13 } sc800t3TXDNoTrans OBJECT IDENTIFIER ::= { sc800t3Alarms 14 } sc800t3RemoteNotResponding OBJECT IDENTIFIER ::= { sc800t3Alarms 15 } sc800t3TopPowerSupplyFail OBJECT IDENTIFIER ::= { sc800t3Alarms 16 } sc800t3BottomPowerSupplyFail OBJECT IDENTIFIER ::= { sc800t3Alarms 17 } sc800t3DTETest OBJECT IDENTIFIER ::= { sc800t3Alarms 18 } sc800t3RAI OBJECT IDENTIFIER ::= { sc800t3Alarms 19 } sc800t3ES OBJECT IDENTIFIER ::= { sc800t3Alarms 20 } sc800t3SES OBJECT IDENTIFIER ::= { sc800t3Alarms 21 } sc800t3SAS OBJECT IDENTIFIER ::= { sc800t3Alarms 22 } sc800t3UAS OBJECT IDENTIFIER ::= { sc800t3Alarms 23 } sc800t3CodeViolations OBJECT IDENTIFIER ::= { sc800t3Alarms 24 } sc800t3ESline OBJECT IDENTIFIER ::= { sc800t3Alarms 25 } -- ALARM Maskable thres Type -- ============================================================================ -- sc800t3NoResponse no no major -- sc800t3DiagRxErrAlm no no major -- sc800t3PowerUpAlm no no major -- sc800t3POSTFail no no major -- sc800t3UnsolicitedTest yes no major -- sc800t3ConfigChange yes no major -- sc800t3TimingLoss yes no major -- sc800t3LossOfSignal yes no major -- sc800t3OutOfFrame yes no major -- sc800t3AIS yes no major -- sc800t3DTEReadyLoss yes no major -- sc800t3DTETXCLKLoss yes no major -- sc800t3RXDNoTrans yes no major -- sc800t3TXDNoTrans yes no major -- sc800t3RemoteNotResponding yes no major -- sc800t3TopPowerSupplyFail yes no minor -- sc800t3BottomPowerSupplyFail yes no minor -- sc800t3DTETest yes no major -- sc800t3RAI yes no major -- sc800t3ES yes yes minor -- sc800t3SES yes yes major -- sc800t3SAS yes yes major -- sc800t3UAS yes yes major -- sc800t3CodeViolations Yes yes minor -- sc800t3ESline yes yes major -- Alarm Scan octet String (scmNodeCurrentAlarms in scmNodeTable from GDCSCM-MIB) -- 1.7 f/u -- 1.6 f/u -- 1.5 OOF -- 1.4 Power-Up -- 1.3 AIS -- 1.2 f/u -- 1.1 Timing Loss -- 1.0 f/u -- -- 2.7 f/u -- 2.6 f/u -- 2.5 f/u -- 2.4 DTE Test -- 2.3 f/u -- 2.2 TXD Loss (transitions) -- 2.1 RXD Loss (transitions) -- 2.0 LOS -- -- 3.7 f/u -- 3.6 POST Failed -- 3.5 Unsolicited Test -- 3.4 Config Change -- 3.3 Top Supply Fail -- 3.2 Bottom Supply Fail -- 3.1 Remote Not Resp -- 3.0 DTE Transmit Clock Loss -- -- 4.7 f/u -- 4.6 DTE Ready Loss -- 4.5 f/u -- 4.4 f/u -- 4.3 f/u -- 4.2 f/u -- 4.1 f/u -- 4.0 RAI -- 5.7 f/u -- 5.6 f/u -- 5.5 ES line -- 5.4 ES -- 5.3 SES -- 5.2 SAS - Severely Errored Frame/AIS -- 5.1 UAS -- 5.0 Code Violations -- **************************************************************************** -- Alarm Thresholds -- **************************************************************************** sc800t3AlarmConfigTable OBJECT-TYPE SYNTAX SEQUENCE OF Sc800t3AlarmConfigEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "The sc800t3AlarmConfigTable contains entries that configure alarm reporting. The structure of the table is such that alarm configuration is supported on a unit and interface basis, and then on an alarm type basis within the interface. For simplicity sake alarms, be they unit or interface related, are represented in one table." ::= { sc800t3AlarmConfig 1 } sc800t3AlarmConfigEntry OBJECT-TYPE SYNTAX Sc800t3AlarmConfigEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "An entry in the GDC Alarm Configuration table." INDEX { sc800t3AlarmConfigIndex, sc800t3AlarmConfigIdentifier } ::= { sc800t3AlarmConfigTable 1 } Sc800t3AlarmConfigEntry ::= SEQUENCE { sc800t3AlarmConfigIndex SCinstance, sc800t3AlarmConfigIdentifier OBJECT IDENTIFIER, sc800t3AlarmCountWindow INTEGER, sc800t3AlarmCountThreshold INTEGER } sc800t3AlarmConfigIndex OBJECT-TYPE SYNTAX SCinstance ACCESS read-only STATUS mandatory DESCRIPTION "Integer value which uniquely identifies the SC800T3 to which this entry is applicable. SCinstance is defined to be SLDi where: S (byte value) - physical shelf slot location (01-32) L (byte value) - line number (01) D (byte value) - drop number (00) i (byte value) - interface number (00)" ::= { sc800t3AlarmConfigEntry 1 } sc800t3AlarmConfigIdentifier OBJECT-TYPE SYNTAX OBJECT IDENTIFIER ACCESS read-only STATUS mandatory DESCRIPTION "format: iso.org.dod.internet.private.enterprises.gdc. ds3.sc800t3.sc800t3Alarms.ALM example: 1.3.6.1.4.1.498.19.1.5.ALM where ALM = 1 for sc800t3NoResponse alarm, 2 for sc800t3DiagRxErr alarm, etc., as specified in the Alarm Definitions above." ::= { sc800t3AlarmConfigEntry 2 } sc800t3AlarmCountWindow OBJECT-TYPE SYNTAX INTEGER{ reportAll(1), last1sec(2), last1min(3), last1hr(4), reportWhen(5) } ACCESS read-write STATUS mandatory DESCRIPTION "This variable sets/reads the alarm window. This window is used with the alarm threshold to determine how long the alarm should be active before reporting." ::= { sc800t3AlarmConfigEntry 3 } sc800t3AlarmCountThreshold OBJECT-TYPE SYNTAX INTEGER { thresGT10(1), thresGT100(2), thresGT1000(3), thresGT10000(4), thresGT100000(5), thresGT1000000(6) } ACCESS read-write STATUS mandatory DESCRIPTION "This function sets/reads the alarm threshold criteria. This threshold is used along with the the alarm window to determine the number of instances in a given time frame for an alarm to occur before the alarm is considered active." ::= { sc800t3AlarmConfigEntry 4 } -- ******************************************************************** -- Performance Tables -- ******************************************************************** -- ******************************************************************** -- Current Near End -- ******************************************************************** sc800t3CurrentNearEndTable OBJECT-TYPE SYNTAX SEQUENCE OF Sc800t3CurrentNearEndEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Gives the statistic count for the current 15 minute interval." ::= { sc800t3Performance 1 } sc800t3CurrentNearEndEntry OBJECT-TYPE SYNTAX Sc800t3CurrentNearEndEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "An entry in the sc800t3 CurrentNearEnd table." INDEX { sc800t3CurrentNearEndIndex } ::= { sc800t3CurrentNearEndTable 1 } Sc800t3CurrentNearEndEntry ::= SEQUENCE { sc800t3CurrentNearEndIndex SCinstance, sc800t3CurrentNearEndStat OCTET STRING } sc800t3CurrentNearEndIndex OBJECT-TYPE SYNTAX SCinstance ACCESS read-only STATUS mandatory DESCRIPTION "Integer value which uniquely identifies the SC800T3 to which this entry is applicable. SCinstance is defined to be SLDi where: S (byte value) - physical shelf slot location (01-32) L (byte value) - line number (01) D (byte value) - drop number (00) i (byte value) - interface number (00)" ::= { sc800t3CurrentNearEndEntry 1 } sc800t3CurrentNearEndStat OBJECT-TYPE SYNTAX OCTET STRING (SIZE (11)) ACCESS read-only STATUS mandatory DESCRIPTION "Returns a bitwise snapshot of the statistics. Octet 1 bit 7 - parity bit 6 - Invalid Data Flag bit 5 - n/a bit 4 - n/a bit 3 - n/a bit 2 - 2^9 Errored Seconds (ES) bit 1 - 2^8 bit 0 - 2^7 Octet 2 bit 7 - parity bit 6 - 2^6 Errored Seconds (ES) bit 5 - 2^5 bit 4 - 2^4 bit 3 - 2^3 bit 2 - 2^2 bit 1 - 2^1 bit 0 - 2^0 Octet 3 bit 7 - parity Severely Errored Seconds (SES) bit 6 - Invalid Data Flag bit 5 - 2^5 bit 4 - 2^4 bit 3 - 2^3 bit 2 - 2^2 bit 1 - 2^1 bit 0 - 2^0 Octet 4 bit 7 - parity Severely Errored Frames (SAS) bit 6 - Invalid Data Flag bit 5 - 2^5 bit 4 - 2^4 bit 3 - 2^3 bit 2 - 2^2 bit 1 - 2^1 bit 0 - 2^0 Octet 5 bit 7 - parity Unavailable Seconds (UAS) bit 6 - Invalid Data Flag bit 5 - 2^5 bit 4 - 2^4 bit 3 - 2^3 bit 2 - 2^2 bit 1 - 2^1 bit 0 - 2^0 Octet 6 bit 7 - parity Code Violations (CV) bit 6 - Invalid Data Flag bit 5 - n/a bit 4 - n/a bit 3 - n/a bit 2 - n/a bit 1 - n/a bit 0 - n/a Octet 7 bit 7 - parity bit 6 - 2^13 Code Violations (CV) bit 5 - 2^12 bit 4 - 2^11 bit 3 - 2^10 bit 2 - 2^9 bit 1 - 2^8 bit 0 - 2^7 Octet 8 bit 7 - parity bit 6 - 2^6 Code Violations (CV) bit 5 - 2^5 bit 4 - 2^4 bit 3 - 2^3 bit 2 - 2^2 bit 1 - 2^1 bit 0 - 2^0 Octet 9 bit 7 - parity bit 6 - Invalid Data Flag bit 5 - n/a bit 4 - n/a bit 3 - n/a bit 2 - 2^9 Errored Seconds Line (ESl) bit 1 - 2^8 bit 0 - 2^7 Octet 10 bit 7 - parity bit 6 - 2^6 Errored Seconds Line (ESl) bit 5 - 2^5 bit 4 - 2^4 bit 3 - 2^3 bit 2 - 2^2 bit 1 - 2^1 bit 0 - 2^0 Octet 11 bit 7 - parity bit 6 - 2^6 Percent Complete bit 5 - 2^5 bit 4 - 2^4 bit 3 - 2^3 bit 2 - 2^2 bit 1 - 2^1 bit 0 - 2^0" ::= { sc800t3CurrentNearEndEntry 2 } -- ******************************************************************** -- Current Far End -- ******************************************************************** sc800t3CurrentFarEndTable OBJECT-TYPE SYNTAX SEQUENCE OF Sc800t3CurrentFarEndEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Gives the statistic count for the current 15 minute interval." ::= { sc800t3Performance 3 } sc800t3CurrentFarEndEntry OBJECT-TYPE SYNTAX Sc800t3CurrentFarEndEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "An entry in the sc800t3 CurrentFarEnd table." INDEX { sc800t3CurrentFarEndIndex } ::= { sc800t3CurrentFarEndTable 1 } Sc800t3CurrentFarEndEntry ::= SEQUENCE { sc800t3CurrentFarEndIndex SCinstance, sc800t3CurrentFarEndStat OCTET STRING } sc800t3CurrentFarEndIndex OBJECT-TYPE SYNTAX SCinstance ACCESS read-only STATUS mandatory DESCRIPTION "Integer value which uniquely identifies the SC800T3 to which this entry is applicable. SCinstance is defined to be SLDi where: S (byte value) - physical shelf slot location (01-32) L (byte value) - line number (01) D (byte value) - drop number (00) i (byte value) - interface number (00)" ::= { sc800t3CurrentFarEndEntry 1 } sc800t3CurrentFarEndStat OBJECT-TYPE SYNTAX OCTET STRING (SIZE (9)) ACCESS read-only STATUS mandatory DESCRIPTION "Returns a bitwise snapshot of the statistics. Octet 1 bit 7 - parity bit 6 - Invalid Data Flag bit 5 - n/a bit 4 - n/a bit 3 - n/a bit 2 - 2^9 Errored Seconds (ES) bit 1 - 2^8 bit 0 - 2^7 Octet 2 bit 7 - parity bit 6 - 2^6 Errored Seconds (ES) bit 5 - 2^5 bit 4 - 2^4 bit 3 - 2^3 bit 2 - 2^2 bit 1 - 2^1 bit 0 - 2^0 Octet 3 bit 7 - parity Severely Errored Seconds (SES) bit 6 - Invalid Data Flag bit 5 - 2^5 bit 4 - 2^4 bit 3 - 2^3 bit 2 - 2^2 bit 1 - 2^1 bit 0 - 2^0 Octet 4 bit 7 - parity Severely Errored Frames (SAS) bit 6 - Invalid Data Flag bit 5 - 2^5 bit 4 - 2^4 bit 3 - 2^3 bit 2 - 2^2 bit 1 - 2^1 bit 0 - 2^0 Octet 5 bit 7 - parity Unavailable Seconds (UAS) bit 6 - Invalid Data Flag bit 5 - 2^5 bit 4 - 2^4 bit 3 - 2^3 bit 2 - 2^2 bit 1 - 2^1 bit 0 - 2^0 Octet 6 bit 7 - parity Code Violations (CV) bit 6 - Invalid Data Flag bit 5 - n/a bit 4 - n/a bit 3 - n/a bit 2 - n/a bit 1 - n/a bit 0 - n/a Octet 7 bit 7 - parity bit 6 - 2^13 Code Violations (CV) bit 5 - 2^12 bit 4 - 2^11 bit 3 - 2^10 bit 2 - 2^9 bit 1 - 2^8 bit 0 - 2^7 Octet 8 bit 7 - parity bit 6 - 2^6 Code Violations (CV) bit 5 - 2^5 bit 4 - 2^4 bit 3 - 2^3 bit 2 - 2^2 bit 1 - 2^1 bit 0 - 2^0 Octet 9 bit 7 - parity bit 6 - 2^6 Percent Complete bit 5 - 2^5 bit 4 - 2^4 bit 3 - 2^3 bit 2 - 2^2 bit 1 - 2^1 bit 0 - 2^0" ::= { sc800t3CurrentFarEndEntry 2 } -- ******************************************************************** -- Current Day Near End -- ******************************************************************** sc800t3CurrentDayNearEndTable OBJECT-TYPE SYNTAX SEQUENCE OF Sc800t3CurrentDayNearEndEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Gives totals for the current day of all the near end statistics." ::= { sc800t3Performance 4 } sc800t3CurrentDayNearEndEntry OBJECT-TYPE SYNTAX Sc800t3CurrentDayNearEndEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "An entry in the sc800t3 CurrentDayNearEndTable." INDEX { sc800t3CurrentDayNearEndIndex } ::= { sc800t3CurrentDayNearEndTable 1 } Sc800t3CurrentDayNearEndEntry ::= SEQUENCE { sc800t3CurrentDayNearEndIndex SCinstance, sc800t3CurrentDayNearEndStat OCTET STRING } sc800t3CurrentDayNearEndIndex OBJECT-TYPE SYNTAX SCinstance ACCESS read-only STATUS mandatory DESCRIPTION "Integer value which uniquely identifies the SC800T3 to which this entry is applicable. SCinstance is defined to be SLDi where: S (byte value) - physical shelf slot location (01-32) L (byte value) - line number (01) D (byte value) - drop number (00) i (byte value) - interface number (00)" ::= { sc800t3CurrentDayNearEndEntry 1 } sc800t3CurrentDayNearEndStat OBJECT-TYPE SYNTAX OCTET STRING (SIZE (18)) ACCESS read-only STATUS mandatory DESCRIPTION "Returns a bitwise snapshot of the statistics. Octet 1 bit 7 - parity bit 6 - Invalid Data Flag bit 5 - n/a bit 4 - n/a bit 3 - n/a bit 2 - n/a bit 1 - 2^15 Errored Seconds (ES) bit 0 - 2^14 Octet 2 bit 7 - parity bit 6 - 2^13 Errored Seconds (ES) bit 5 - 2^12 bit 4 - 2^11 bit 3 - 2^10 bit 2 - 2^9 bit 1 - 2^8 bit 0 - 2^7 Octet 3 bit 7 - parity bit 6 - 2^6 Errored Seconds (ES) bit 5 - 2^5 bit 4 - 2^4 bit 3 - 2^3 bit 2 - 2^2 bit 1 - 2^1 bit 0 - 2^0 Octet 4 bit 7 - parity Severely Errored Seconds (SES) bit 6 - Invalid Data Flag bit 5 - n/a bit 4 - 2^11 bit 3 - 2^10 bit 2 - 2^9 bit 1 - 2^8 bit 0 - 2^7 Octet 5 bit 7 - parity bit 6 - 2^6 Severely Errored Seconds (SES) bit 5 - 2^5 bit 4 - 2^4 bit 3 - 2^3 bit 2 - 2^2 bit 1 - 2^1 bit 0 - 2^0 Octet 6 bit 7 - parity Severely Errored Frame (SAS) bit 6 - Invalid Data Flag bit 5 - n/a bit 4 - 2^11 bit 3 - 2^10 bit 2 - 2^9 bit 1 - 2^8 bit 0 - 2^7 Octet 7 bit 7 - parity bit 6 - 2^6 Severely Errored Frame (SAS) bit 5 - 2^5 bit 4 - 2^4 bit 3 - 2^3 bit 2 - 2^2 bit 1 - 2^1 bit 0 - 2^0 Octet 8 bit 7 - parity Unavailable Seconds (UAS) bit 6 - Invalid Data Flag bit 5 - n/a bit 4 - 2^11 bit 3 - 2^10 bit 2 - 2^9 bit 1 - 2^8 bit 0 - 2^7 Octet 9 bit 7 - parity bit 6 - 2^6 Unavailable Seconds (UAS) bit 5 - 2^5 bit 4 - 2^4 bit 3 - 2^3 bit 2 - 2^2 bit 1 - 2^1 bit 0 - 2^0 Octet 10 bit 7 - parity Code Violations (CV) bit 6 - Invalid Data Flag bit 5 - 2^19 bit 4 - 2^18 bit 3 - 2^17 bit 2 - 2^16 bit 1 - 2^15 bit 0 - 2^14 Octet 11 bit 7 - parity bit 6 - 2^13 Code Violations (CV) bit 5 - 2^12 bit 4 - 2^11 bit 3 - 2^10 bit 2 - 2^9 bit 1 - 2^8 bit 0 - 2^7 Octet 12 bit 7 - parity bit 6 - 2^6 Code Violations (CV) bit 5 - 2^5 bit 4 - 2^4 bit 3 - 2^3 bit 2 - 2^2 bit 1 - 2^1 bit 0 - 2^0 Octet 13 bit 7 - parity bit 6 - Invalid Data Flag bit 5 - n/a bit 4 - n/a bit 3 - n/a bit 2 - n/a bit 1 - 2^15 Errored Seconds Line (ESl) bit 0 - 2^14 Octet 14 bit 7 - parity bit 6 - 2^13 Errored Seconds Line (ESl) bit 5 - 2^12 bit 4 - 2^11 bit 3 - 2^10 bit 2 - 2^9 bit 1 - 2^8 bit 0 - 2^7 Octet 15 bit 7 - parity bit 6 - 2^6 Errored Seconds Line (ESl) bit 5 - 2^5 bit 4 - 2^4 bit 3 - 2^3 bit 2 - 2^2 bit 1 - 2^1 bit 0 - 2^0 Octet 16 bit 7 - parity bit 6 - Invalid Data Flag bit 5 - n/a bit 4 - n/a bit 3 - n/a bit 2 - n/a bit 1 - 2^15 FC-P Path Failure Events bit 0 - 2^14 Octet 17 bit 7 - parity bit 6 - 2^13 FC-P Path Failure Events bit 5 - 2^12 bit 4 - 2^11 bit 3 - 2^10 bit 2 - 2^9 bit 1 - 2^8 bit 0 - 2^7 Octet 18 bit 7 - parity bit 6 - 2^6 FC-P Path Failure Events bit 5 - 2^5 bit 4 - 2^4 bit 3 - 2^3 bit 2 - 2^2 bit 1 - 2^1 bit 0 - 2^0" ::= { sc800t3CurrentDayNearEndEntry 2 } -- ******************************************************************** -- Current Day Far End -- ******************************************************************** sc800t3CurrentDayFarEndTable OBJECT-TYPE SYNTAX SEQUENCE OF Sc800t3CurrentDayFarEndEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Gives totals for the current day of all the Far End statistics." ::= { sc800t3Performance 6 } sc800t3CurrentDayFarEndEntry OBJECT-TYPE SYNTAX Sc800t3CurrentDayFarEndEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "An entry in the sc800t3CurrentDayFarEndTable." INDEX { sc800t3CurrentDayFarEndIndex } ::= { sc800t3CurrentDayFarEndTable 1 } Sc800t3CurrentDayFarEndEntry ::= SEQUENCE { sc800t3CurrentDayFarEndIndex SCinstance, sc800t3CurrentDayFarEndStat OCTET STRING } sc800t3CurrentDayFarEndIndex OBJECT-TYPE SYNTAX SCinstance ACCESS read-only STATUS mandatory DESCRIPTION "Integer value which uniquely identifies the SC800T3 to which this entry is applicable. SCinstance is defined to be SLDi where: S (byte value) - physical shelf slot location (01-32) L (byte value) - line number (01) D (byte value) - drop number (00) i (byte value) - interface number (00)" ::= { sc800t3CurrentDayFarEndEntry 1 } sc800t3CurrentDayFarEndStat OBJECT-TYPE SYNTAX OCTET STRING (SIZE (15)) ACCESS read-only STATUS mandatory DESCRIPTION "Returns a bitwise snapshot of the statistics. Octet 1 bit 7 - parity bit 6 - Invalid Data Flag bit 5 - n/a bit 4 - n/a bit 3 - n/a bit 2 - n/a bit 1 - 2^15 Errored Seconds (ES) bit 0 - 2^14 Octet 2 bit 7 - parity bit 6 - 2^13 Errored Seconds (ES) bit 5 - 2^12 bit 4 - 2^11 bit 3 - 2^10 bit 2 - 2^9 bit 1 - 2^8 bit 0 - 2^7 Octet 3 bit 7 - parity bit 6 - 2^6 Errored Seconds (ES) bit 5 - 2^5 bit 4 - 2^4 bit 3 - 2^3 bit 2 - 2^2 bit 1 - 2^1 bit 0 - 2^0 Octet 4 bit 7 - parity Severely Errored Seconds (SES) bit 6 - Invalid Data Flag bit 5 - n/a bit 4 - 2^11 bit 3 - 2^10 bit 2 - 2^9 bit 1 - 2^8 bit 0 - 2^7 Octet 5 bit 7 - parity bit 6 - 2^6 Severely Errored Seconds (SES) bit 5 - 2^5 bit 4 - 2^4 bit 3 - 2^3 bit 2 - 2^2 bit 1 - 2^1 bit 0 - 2^0 Octet 6 bit 7 - parity Severely Errored Frame (SAS) bit 6 - Invalid Data Flag bit 5 - n/a bit 4 - 2^11 bit 3 - 2^10 bit 2 - 2^9 bit 1 - 2^8 bit 0 - 2^7 Octet 7 bit 7 - parity bit 6 - 2^6 Severely Errored Frame (SAS) bit 5 - 2^5 bit 4 - 2^4 bit 3 - 2^3 bit 2 - 2^2 bit 1 - 2^1 bit 0 - 2^0 Octet 8 bit 7 - parity Unavailable Seconds (UAS) bit 6 - Invalid Data Flag bit 5 - n/a bit 4 - 2^11 bit 3 - 2^10 bit 2 - 2^9 bit 1 - 2^8 bit 0 - 2^7 Octet 9 bit 7 - parity bit 6 - 2^6 Unavailable Seconds (UAS) bit 5 - 2^5 bit 4 - 2^4 bit 3 - 2^3 bit 2 - 2^2 bit 1 - 2^1 bit 0 - 2^0 Octet 10 bit 7 - parity Code Violations (CV) bit 6 - Invalid Data Flag bit 5 - 2^19 bit 4 - 2^18 bit 3 - 2^17 bit 2 - 2^16 bit 1 - 2^15 bit 0 - 2^14 Octet 11 bit 7 - parity bit 6 - 2^13 Code Violations (CV) bit 5 - 2^12 bit 4 - 2^11 bit 3 - 2^10 bit 2 - 2^9 bit 1 - 2^8 bit 0 - 2^7 Octet 12 bit 7 - parity bit 6 - 2^6 Code Violations (CV) bit 5 - 2^5 bit 4 - 2^4 bit 3 - 2^3 bit 2 - 2^2 bit 1 - 2^1 bit 0 - 2^0 Octet 13 bit 7 - parity FCCP-PFE Path Failure Events bit 6 - Invalid Data Flag bit 5 - n/a bit 4 - n/a bit 3 - n/a bit 2 - n/a bit 1 - 2^15 bit 0 - 2^14 Octet 14 bit 7 - parity bit 6 - 2^13 FCCP-PFE Path Failure Events bit 5 - 2^12 bit 4 - 2^11 bit 3 - 2^10 bit 2 - 2^9 bit 1 - 2^8 bit 0 - 2^7 Octet 15 bit 7 - parity bit 6 - 2^6 FCCP-PFE Path Failure Events bit 5 - 2^5 bit 4 - 2^4 bit 3 - 2^3 bit 2 - 2^2 bit 1 - 2^1 bit 0 - 2^0" ::= { sc800t3CurrentDayFarEndEntry 2 } -- ******************************************************************** -- Previous Day Near End -- ******************************************************************** sc800t3PreviousDayNearEndTable OBJECT-TYPE SYNTAX SEQUENCE OF Sc800t3PreviousDayNearEndEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Gives totals for the previous day of all the near end statistics." ::= { sc800t3Performance 2 } sc800t3PreviousDayNearEndEntry OBJECT-TYPE SYNTAX Sc800t3PreviousDayNearEndEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "An entry in the sc800t3 PreviousDayNearEndTable." INDEX { sc800t3PreviousDayNearEndIndex } ::= { sc800t3PreviousDayNearEndTable 1 } Sc800t3PreviousDayNearEndEntry ::= SEQUENCE { sc800t3PreviousDayNearEndIndex SCinstance, sc800t3PreviousDayNearEndStat OCTET STRING } sc800t3PreviousDayNearEndIndex OBJECT-TYPE SYNTAX SCinstance ACCESS read-only STATUS mandatory DESCRIPTION "Integer value which uniquely identifies the SC800T3 to which this entry is applicable. SCinstance is defined to be SLDi where: S (byte value) - physical shelf slot location (01-32) L (byte value) - line number (01) D (byte value) - drop number (00) i (byte value) - interface number (00)" ::= { sc800t3PreviousDayNearEndEntry 1 } sc800t3PreviousDayNearEndStat OBJECT-TYPE SYNTAX OCTET STRING (SIZE (18)) ACCESS read-only STATUS mandatory DESCRIPTION "Returns a bitwise snapshot of the statistics. Octet 1 bit 7 - parity bit 6 - Invalid Data Flag bit 5 - n/a bit 4 - n/a bit 3 - n/a bit 2 - n/a bit 1 - 2^15 Errored Seconds (ES) bit 0 - 2^14 Octet 2 bit 7 - parity bit 6 - 2^13 Errored Seconds (ES) bit 5 - 2^12 bit 4 - 2^11 bit 3 - 2^10 bit 2 - 2^9 bit 1 - 2^8 bit 0 - 2^7 Octet 3 bit 7 - parity bit 6 - 2^6 Errored Seconds (ES) bit 5 - 2^5 bit 4 - 2^4 bit 3 - 2^3 bit 2 - 2^2 bit 1 - 2^1 bit 0 - 2^0 Octet 4 bit 7 - parity Severely Errored Seconds (SES) bit 6 - Invalid Data Flag bit 5 - n/a bit 4 - 2^11 bit 3 - 2^10 bit 2 - 2^9 bit 1 - 2^8 bit 0 - 2^7 Octet 5 bit 7 - parity bit 6 - 2^6 Severely Errored Seconds (SES) bit 5 - 2^5 bit 4 - 2^4 bit 3 - 2^3 bit 2 - 2^2 bit 1 - 2^1 bit 0 - 2^0 Octet 6 bit 7 - parity Severely Errored Frame (SAS) bit 6 - Invalid Data Flag bit 5 - n/a bit 4 - 2^11 bit 3 - 2^10 bit 2 - 2^9 bit 1 - 2^8 bit 0 - 2^7 Octet 7 bit 7 - parity bit 6 - 2^6 Severely Errored Frame (SAS) bit 5 - 2^5 bit 4 - 2^4 bit 3 - 2^3 bit 2 - 2^2 bit 1 - 2^1 bit 0 - 2^0 Octet 8 bit 7 - parity Unavailable Seconds (UAS) bit 6 - Invalid Data Flag bit 5 - n/a bit 4 - 2^11 bit 3 - 2^10 bit 2 - 2^9 bit 1 - 2^8 bit 0 - 2^7 Octet 9 bit 7 - parity bit 6 - 2^6 Unavailable Seconds (UAS) bit 5 - 2^5 bit 4 - 2^4 bit 3 - 2^3 bit 2 - 2^2 bit 1 - 2^1 bit 0 - 2^0 Octet 10 bit 7 - parity Code Violations (CV) bit 6 - Invalid Data Flag bit 5 - 2^19 bit 4 - 2^18 bit 3 - 2^17 bit 2 - 2^16 bit 1 - 2^15 bit 0 - 2^14 Octet 11 bit 7 - parity bit 6 - 2^13 Code Violations (CV) bit 5 - 2^12 bit 4 - 2^11 bit 3 - 2^10 bit 2 - 2^9 bit 1 - 2^8 bit 0 - 2^7 Octet 12 bit 7 - parity bit 6 - 2^6 Code Violations (CV) bit 5 - 2^5 bit 4 - 2^4 bit 3 - 2^3 bit 2 - 2^2 bit 1 - 2^1 bit 0 - 2^0 Octet 13 bit 7 - parity bit 6 - Invalid Data Flag bit 5 - n/a bit 4 - n/a bit 3 - n/a bit 2 - n/a bit 1 - 2^15 Errored Seconds Line (ESl) bit 0 - 2^14 Octet 14 bit 7 - parity bit 6 - 2^13 Errored Seconds Line (ESl) bit 5 - 2^12 bit 4 - 2^11 bit 3 - 2^10 bit 2 - 2^9 bit 1 - 2^8 bit 0 - 2^7 Octet 15 bit 7 - parity bit 6 - 2^6 Errored Seconds Line (ESl) bit 5 - 2^5 bit 4 - 2^4 bit 3 - 2^3 bit 2 - 2^2 bit 1 - 2^1 bit 0 - 2^0 Octet 16 bit 7 - parity bit 6 - Invalid Data Flag bit 5 - n/a bit 4 - n/a bit 3 - n/a bit 2 - n/a bit 1 - 2^15 FC-P Path Failure Events bit 0 - 2^14 Octet 17 bit 7 - parity bit 6 - 2^13 FC-P Path Failure Events bit 5 - 2^12 bit 4 - 2^11 bit 3 - 2^10 bit 2 - 2^9 bit 1 - 2^8 bit 0 - 2^7 Octet 18 bit 7 - parity bit 6 - 2^6 FC-P Path Failure Events bit 5 - 2^5 bit 4 - 2^4 bit 3 - 2^3 bit 2 - 2^2 bit 1 - 2^1 bit 0 - 2^0" ::= { sc800t3PreviousDayNearEndEntry 2 } -- ******************************************************************** -- Previous Day Far End -- ******************************************************************** sc800t3PreviousDayFarEndTable OBJECT-TYPE SYNTAX SEQUENCE OF Sc800t3PreviousDayFarEndEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Gives totals for the previous day of all the Far End statistics." ::= { sc800t3Performance 5 } sc800t3PreviousDayFarEndEntry OBJECT-TYPE SYNTAX Sc800t3PreviousDayFarEndEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "An entry in the sc800t3PreviousDayFarEndTable." INDEX { sc800t3PreviousDayFarEndIndex } ::= { sc800t3PreviousDayFarEndTable 1 } Sc800t3PreviousDayFarEndEntry ::= SEQUENCE { sc800t3PreviousDayFarEndIndex SCinstance, sc800t3PreviousDayFarEndStat OCTET STRING } sc800t3PreviousDayFarEndIndex OBJECT-TYPE SYNTAX SCinstance ACCESS read-only STATUS mandatory DESCRIPTION "Integer value which uniquely identifies the SC800T3 to which this entry is applicable. SCinstance is defined to be SLDi where: S (byte value) - physical shelf slot location (01-32) L (byte value) - line number (01) D (byte value) - drop number (00) i (byte value) - interface number (00)" ::= { sc800t3PreviousDayFarEndEntry 1 } sc800t3PreviousDayFarEndStat OBJECT-TYPE SYNTAX OCTET STRING (SIZE (15)) ACCESS read-only STATUS mandatory DESCRIPTION "Returns a bitwise snapshot of the statistics. Octet 1 bit 7 - parity bit 6 - Invalid Data Flag bit 5 - n/a bit 4 - n/a bit 3 - n/a bit 2 - n/a bit 1 - 2^15 Errored Seconds (ES) bit 0 - 2^14 Octet 2 bit 7 - parity bit 6 - 2^13 Errored Seconds (ES) bit 5 - 2^12 bit 4 - 2^11 bit 3 - 2^10 bit 2 - 2^9 bit 1 - 2^8 bit 0 - 2^7 Octet 3 bit 7 - parity bit 6 - 2^6 Errored Seconds (ES) bit 5 - 2^5 bit 4 - 2^4 bit 3 - 2^3 bit 2 - 2^2 bit 1 - 2^1 bit 0 - 2^0 Octet 4 bit 7 - parity Severely Errored Seconds (SES) bit 6 - Invalid Data Flag bit 5 - n/a bit 4 - 2^11 bit 3 - 2^10 bit 2 - 2^9 bit 1 - 2^8 bit 0 - 2^7 Octet 5 bit 7 - parity bit 6 - 2^6 Severely Errored Seconds (SES) bit 5 - 2^5 bit 4 - 2^4 bit 3 - 2^3 bit 2 - 2^2 bit 1 - 2^1 bit 0 - 2^0 Octet 6 bit 7 - parity Severely Errored Frame (SAS) bit 6 - Invalid Data Flag bit 5 - n/a bit 4 - 2^11 bit 3 - 2^10 bit 2 - 2^9 bit 1 - 2^8 bit 0 - 2^7 Octet 7 bit 7 - parity bit 6 - 2^6 Severely Errored Frame (SAS) bit 5 - 2^5 bit 4 - 2^4 bit 3 - 2^3 bit 2 - 2^2 bit 1 - 2^1 bit 0 - 2^0 Octet 8 bit 7 - parity Unavailable Seconds (UAS) bit 6 - Invalid Data Flag bit 5 - n/a bit 4 - 2^11 bit 3 - 2^10 bit 2 - 2^9 bit 1 - 2^8 bit 0 - 2^7 Octet 9 bit 7 - parity bit 6 - 2^6 Unavailable Seconds (UAS) bit 5 - 2^5 bit 4 - 2^4 bit 3 - 2^3 bit 2 - 2^2 bit 1 - 2^1 bit 0 - 2^0 Octet 10 bit 7 - parity Code Violations (CV) bit 6 - Invalid Data Flag bit 5 - 2^19 bit 4 - 2^18 bit 3 - 2^17 bit 2 - 2^16 bit 1 - 2^15 bit 0 - 2^14 Octet 11 bit 7 - parity bit 6 - 2^13 Code Violations (CV) bit 5 - 2^12 bit 4 - 2^11 bit 3 - 2^10 bit 2 - 2^9 bit 1 - 2^8 bit 0 - 2^7 Octet 12 bit 7 - parity bit 6 - 2^6 Code Violations (CV) bit 5 - 2^5 bit 4 - 2^4 bit 3 - 2^3 bit 2 - 2^2 bit 1 - 2^1 bit 0 - 2^0 Octet 13 bit 7 - parity FCCP-PFE Path Failure Events bit 6 - Invalid Data Flag bit 5 - n/a bit 4 - n/a bit 3 - n/a bit 2 - n/a bit 1 - 2^15 bit 0 - 2^14 Octet 14 bit 7 - parity bit 6 - 2^13 FCCP-PFE Path Failure Events bit 5 - 2^12 bit 4 - 2^11 bit 3 - 2^10 bit 2 - 2^9 bit 1 - 2^8 bit 0 - 2^7 Octet 15 bit 7 - parity bit 6 - 2^6 FCCP-PFE Path Failure Events bit 5 - 2^5 bit 4 - 2^4 bit 3 - 2^3 bit 2 - 2^2 bit 1 - 2^1 bit 0 - 2^0" ::= { sc800t3PreviousDayFarEndEntry 2 } -- ******************************************************************** -- Interval Near End -- ******************************************************************** sc800t3NearEndIntervalTable OBJECT-TYPE SYNTAX SEQUENCE OF Sc800t3NearEndIntervalEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "The sc800t3 Near End Interval table." ::= { sc800t3Performance 7 } sc800t3NearEndIntervalEntry OBJECT-TYPE SYNTAX Sc800t3NearEndIntervalEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "An entry in the Interval table." INDEX { sc800t3NearEndIntervalIndex, sc800t3NearEndIntervalNumber } ::= { sc800t3NearEndIntervalTable 1 } Sc800t3NearEndIntervalEntry ::= SEQUENCE { sc800t3NearEndIntervalIndex SCinstance, sc800t3NearEndIntervalNumber INTEGER, sc800t3NearEndIntervalStats OCTET STRING } sc800t3NearEndIntervalIndex OBJECT-TYPE SYNTAX SCinstance ACCESS read-only STATUS mandatory DESCRIPTION "Integer value which uniquely identifies the SC800T3 to which this entry is applicable. SCinstance is defined to be SLDi where: S (byte value) - physical shelf slot location (01-32) L (byte value) - line number (01) D (byte value) - drop number (00) i (byte value) - interface number (00)" ::= { sc800t3NearEndIntervalEntry 1 } sc800t3NearEndIntervalNumber OBJECT-TYPE SYNTAX INTEGER (1..31) ACCESS read-only STATUS mandatory DESCRIPTION "A number between 1 and 31, where 1 is the most recently completed minute interval and 31 is the least recently completed 15 minutes interval (assuming that all 31 intervals are valid)." ::= { sc800t3NearEndIntervalEntry 2 } sc800t3NearEndIntervalStats OBJECT-TYPE SYNTAX OCTET STRING (SIZE (11)) ACCESS read-only STATUS mandatory DESCRIPTION "Returns a bitwise snapshot of the statistics. Octet 1 bit 7 - parity bit 6 - Invalid Data Flag bit 5 - n/a bit 4 - n/a bit 3 - n/a bit 2 - 2^9 Errored Seconds (ES) bit 1 - 2^8 bit 0 - 2^7 Octet 2 bit 7 - parity bit 6 - 2^6 Errored Seconds (ES) bit 5 - 2^5 bit 4 - 2^4 bit 3 - 2^3 bit 2 - 2^2 bit 1 - 2^1 bit 0 - 2^0 Octet 3 bit 7 - parity Severely Errored Seconds (SES) bit 6 - Invalid Data Flag bit 5 - 2^5 bit 4 - 2^4 bit 3 - 2^3 bit 2 - 2^2 bit 1 - 2^1 bit 0 - 2^0 Octet 4 bit 7 - parity Severely Errored Frames (SAS) bit 6 - Invalid Data Flag bit 5 - 2^5 bit 4 - 2^4 bit 3 - 2^3 bit 2 - 2^2 bit 1 - 2^1 bit 0 - 2^0 Octet 5 bit 7 - parity Unavailable Seconds (UAS) bit 6 - Invalid Data Flag bit 5 - 2^5 bit 4 - 2^4 bit 3 - 2^3 bit 2 - 2^2 bit 1 - 2^1 bit 0 - 2^0 Octet 6 bit 7 - parity Code Violations (CV) bit 6 - Invalid Data Flag bit 5 - n/a bit 4 - n/a bit 3 - n/a bit 2 - n/a bit 1 - n/a bit 0 - n/a Octet 7 bit 7 - parity bit 6 - 2^13 Code Violations (CV) bit 5 - 2^12 bit 4 - 2^11 bit 3 - 2^10 bit 2 - 2^9 bit 1 - 2^8 bit 0 - 2^7 Octet 8 bit 7 - parity bit 6 - 2^6 Code Violations (CV) bit 5 - 2^5 bit 4 - 2^4 bit 3 - 2^3 bit 2 - 2^2 bit 1 - 2^1 bit 0 - 2^0 Octet 9 bit 7 - parity bit 6 - Invalid Data Flag bit 5 - n/a bit 4 - n/a bit 3 - n/a bit 2 - 2^9 Errored Seconds Line (ESl) bit 1 - 2^8 bit 0 - 2^7 Octet 10 bit 7 - parity bit 6 - 2^6 Errored Seconds Line (ESl) bit 5 - 2^5 bit 4 - 2^4 bit 3 - 2^3 bit 2 - 2^2 bit 1 - 2^1 bit 0 - 2^0 Octet 11 bit 7 - parity bit 6 - n/a Interval (1-31) bit 5 - n/a bit 4 - 2^4 bit 3 - 2^3 bit 2 - 2^2 bit 1 - 2^1 bit 0 - 2^0" ::= { sc800t3NearEndIntervalEntry 3 } -- ******************************************************************** -- Interval Far End -- ******************************************************************** sc800t3FarEndIntervalTable OBJECT-TYPE SYNTAX SEQUENCE OF Sc800t3FarEndIntervalEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "The sc800t3 Far End Interval table." ::= { sc800t3Performance 9 } sc800t3FarEndIntervalEntry OBJECT-TYPE SYNTAX Sc800t3FarEndIntervalEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "An entry in the Interval table." INDEX { sc800t3FarEndIntervalIndex, sc800t3FarEndIntervalNumber } ::= { sc800t3FarEndIntervalTable 1 } Sc800t3FarEndIntervalEntry ::= SEQUENCE { sc800t3FarEndIntervalIndex SCinstance, sc800t3FarEndIntervalNumber INTEGER, sc800t3FarEndIntervalStats OCTET STRING } sc800t3FarEndIntervalIndex OBJECT-TYPE SYNTAX SCinstance ACCESS read-only STATUS mandatory DESCRIPTION "Integer value which uniquely identifies the SC800T3 to which this entry is applicable. SCinstance is defined to be SLDi where: S (byte value) - physical shelf slot location (01-32) L (byte value) - line number (01) D (byte value) - drop number (00) i (byte value) - interface number (00)" ::= { sc800t3FarEndIntervalEntry 1 } sc800t3FarEndIntervalNumber OBJECT-TYPE SYNTAX INTEGER (1..31) ACCESS read-only STATUS mandatory DESCRIPTION "A number between 1 and 31, where 1 is the most recently completed minute interval and 31 is the least recently completed 15 minutes interval (assuming that all 31 intervals are valid)." ::= { sc800t3FarEndIntervalEntry 2 } sc800t3FarEndIntervalStats OBJECT-TYPE SYNTAX OCTET STRING (SIZE (9)) ACCESS read-only STATUS mandatory DESCRIPTION "Returns a bitwise snapshot of the statistics. Octet 1 bit 7 - parity bit 6 - Invalid Data Flag bit 5 - n/a bit 4 - n/a bit 3 - n/a bit 2 - 2^9 Errored Seconds (ES) bit 1 - 2^8 bit 0 - 2^7 Octet 2 bit 7 - parity bit 6 - 2^6 Errored Seconds (ES) bit 5 - 2^5 bit 4 - 2^4 bit 3 - 2^3 bit 2 - 2^2 bit 1 - 2^1 bit 0 - 2^0 Octet 3 bit 7 - parity Severely Errored Seconds (SES) bit 6 - Invalid Data Flag bit 5 - 2^5 bit 4 - 2^4 bit 3 - 2^3 bit 2 - 2^2 bit 1 - 2^1 bit 0 - 2^0 Octet 4 bit 7 - parity Severely Errored Frames (SAS) bit 6 - Invalid Data Flag bit 5 - 2^5 bit 4 - 2^4 bit 3 - 2^3 bit 2 - 2^2 bit 1 - 2^1 bit 0 - 2^0 Octet 5 bit 7 - parity Unavailable Seconds (UAS) bit 6 - Invalid Data Flag bit 5 - 2^5 bit 4 - 2^4 bit 3 - 2^3 bit 2 - 2^2 bit 1 - 2^1 bit 0 - 2^0 Octet 6 bit 7 - parity Code Violations (CV) bit 6 - Invalid Data Flag bit 5 - n/a bit 4 - n/a bit 3 - n/a bit 2 - n/a bit 1 - n/a bit 0 - n/a Octet 7 bit 7 - parity bit 6 - 2^13 Code Violations (CV) bit 5 - 2^12 bit 4 - 2^11 bit 3 - 2^10 bit 2 - 2^9 bit 1 - 2^8 bit 0 - 2^7 Octet 8 bit 7 - parity bit 6 - 2^6 Code Violations (CV) bit 5 - 2^5 bit 4 - 2^4 bit 3 - 2^3 bit 2 - 2^2 bit 1 - 2^1 bit 0 - 2^0 Octet 9 bit 7 - parity bit 6 - n/a Interval (1-31) bit 5 - n/a bit 4 - 2^4 bit 3 - 2^3 bit 2 - 2^2 bit 1 - 2^1 bit 0 - 2^0" ::= { sc800t3FarEndIntervalEntry 3} -- ******************************************************************** -- Previous Near End -- ******************************************************************** sc800t3PreviousNearEndTable OBJECT-TYPE SYNTAX SEQUENCE OF Sc800t3PreviousNearEndEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Gives the statistic count for the previous 15 minute interval." ::= { sc800t3Performance 10 } sc800t3PreviousNearEndEntry OBJECT-TYPE SYNTAX Sc800t3PreviousNearEndEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "An entry in the sc800t3 PreviousNearEnd table." INDEX { sc800t3PreviousNearEndIndex } ::= { sc800t3PreviousNearEndTable 1 } Sc800t3PreviousNearEndEntry ::= SEQUENCE { sc800t3PreviousNearEndIndex SCinstance, sc800t3PreviousNearEndStat OCTET STRING } sc800t3PreviousNearEndIndex OBJECT-TYPE SYNTAX SCinstance ACCESS read-only STATUS mandatory DESCRIPTION "Integer value which uniquely identifies the SC800T3 to which this entry is applicable. SCinstance is defined to be SLDi where: S (byte value) - physical shelf slot location (01-32) L (byte value) - line number (01) D (byte value) - drop number (00) i (byte value) - interface number (00)" ::= { sc800t3PreviousNearEndEntry 1 } sc800t3PreviousNearEndStat OBJECT-TYPE SYNTAX OCTET STRING (SIZE (11)) ACCESS read-only STATUS mandatory DESCRIPTION "Returns a bitwise snapshot of the statistics. Octet 1 bit 7 - f/u bit 6 - Invalid Data Flag bit 5 - n/a bit 4 - n/a bit 3 - n/a bit 2 - 2^9 Errored Seconds (ES) bit 1 - 2^8 bit 0 - 2^7 Octet 2 bit 7 - f/u bit 6 - 2^6 Errored Seconds (ES) bit 5 - 2^5 bit 4 - 2^4 bit 3 - 2^3 bit 2 - 2^2 bit 1 - 2^1 bit 0 - 2^0 Octet 3 bit 7 - f/u Severely Errored Seconds (SES) bit 6 - Invalid Data Flag bit 5 - 2^5 bit 4 - 2^4 bit 3 - 2^3 bit 2 - 2^2 bit 1 - 2^1 bit 0 - 2^0 Octet 4 bit 7 - f/u Severely Errored Frames (SAS) bit 6 - Invalid Data Flag bit 5 - 2^5 bit 4 - 2^4 bit 3 - 2^3 bit 2 - 2^2 bit 1 - 2^1 bit 0 - 2^0 Octet 5 bit 7 - f/u Unavailable Seconds (UAS) bit 6 - Invalid Data Flag bit 5 - 2^5 bit 4 - 2^4 bit 3 - 2^3 bit 2 - 2^2 bit 1 - 2^1 bit 0 - 2^0 Octet 6 bit 7 - f/u Code Violations (CV) bit 6 - Invalid Data Flag bit 5 - n/a bit 4 - n/a bit 3 - n/a bit 2 - n/a bit 1 - n/a bit 0 - n/a Octet 7 bit 7 - f/u bit 6 - 2^13 Code Violations (CV) bit 5 - 2^12 bit 4 - 2^11 bit 3 - 2^10 bit 2 - 2^9 bit 1 - 2^8 bit 0 - 2^7 Octet 8 bit 7 - f/u bit 6 - 2^6 Code Violations (CV) bit 5 - 2^5 bit 4 - 2^4 bit 3 - 2^3 bit 2 - 2^2 bit 1 - 2^1 bit 0 - 2^0 Octet 9 bit 7 - fu bit 6 - Invalid Data Flag bit 5 - n/a bit 4 - n/a bit 3 - n/a bit 2 - 2^9 Errored Seconds Line (ESl) bit 1 - 2^8 bit 0 - 2^7 Octet 10 bit 7 - f/u bit 6 - 2^6 Errored Seconds Line (ESl) bit 5 - 2^5 bit 4 - 2^4 bit 3 - 2^3 bit 2 - 2^2 bit 1 - 2^1 bit 0 - 2^0 Octet 11 bit 7 - f/u bit 6 - 2^6 Percent Complete bit 5 - 2^5 bit 4 - 2^4 bit 3 - 2^3 bit 2 - 2^2 bit 1 - 2^1 bit 0 - 2^0" ::= { sc800t3PreviousNearEndEntry 2 } -- ******************************************************************** -- Previous Far End -- ******************************************************************** sc800t3PreviousFarEndTable OBJECT-TYPE SYNTAX SEQUENCE OF Sc800t3PreviousFarEndEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Gives the statistic count for the previous 15 minute interval." ::= { sc800t3Performance 11 } sc800t3PreviousFarEndEntry OBJECT-TYPE SYNTAX Sc800t3PreviousFarEndEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "An entry in the sc800t3 PreviousFarEnd table." INDEX { sc800t3PreviousFarEndIndex } ::= { sc800t3PreviousFarEndTable 1 } Sc800t3PreviousFarEndEntry ::= SEQUENCE { sc800t3PreviousFarEndIndex SCinstance, sc800t3PreviousFarEndStat OCTET STRING } sc800t3PreviousFarEndIndex OBJECT-TYPE SYNTAX SCinstance ACCESS read-only STATUS mandatory DESCRIPTION "Integer value which uniquely identifies the SC800T3 to which this entry is applicable. SCinstance is defined to be SLDi where: S (byte value) - physical shelf slot location (01-32) L (byte value) - line number (01) D (byte value) - drop number (00) i (byte value) - interface number (00)" ::= { sc800t3PreviousFarEndEntry 1 } sc800t3PreviousFarEndStat OBJECT-TYPE SYNTAX OCTET STRING (SIZE (8)) ACCESS read-only STATUS mandatory DESCRIPTION "Returns a bitwise snapshot of the statistics. Octet 1 bit 7 - f/u bit 6 - Invalid Data Flag bit 5 - n/a bit 4 - n/a bit 3 - n/a bit 2 - 2^9 Errored Seconds (ES) bit 1 - 2^8 bit 0 - 2^7 Octet 2 bit 7 - f/u bit 6 - 2^6 Errored Seconds (ES) bit 5 - 2^5 bit 4 - 2^4 bit 3 - 2^3 bit 2 - 2^2 bit 1 - 2^1 bit 0 - 2^0 Octet 3 bit 7 - f/u Severely Errored Seconds (SES) bit 6 - Invalid Data Flag bit 5 - 2^5 bit 4 - 2^4 bit 3 - 2^3 bit 2 - 2^2 bit 1 - 2^1 bit 0 - 2^0 Octet 4 bit 7 - f/u Severely Errored Frames (SAS) bit 6 - Invalid Data Flag bit 5 - 2^5 bit 4 - 2^4 bit 3 - 2^3 bit 2 - 2^2 bit 1 - 2^1 bit 0 - 2^0 Octet 5 bit 7 - f/u Unavailable Seconds (UAS) bit 6 - Invalid Data Flag bit 5 - 2^5 bit 4 - 2^4 bit 3 - 2^3 bit 2 - 2^2 bit 1 - 2^1 bit 0 - 2^0 Octet 6 bit 7 - f/u Code Violations (CV) bit 6 - Invalid Data Flag bit 5 - n/a bit 4 - n/a bit 3 - n/a bit 2 - n/a bit 1 - n/a bit 0 - n/a Octet 7 bit 7 - f/u bit 6 - 2^13 Code Violations (CV) bit 5 - 2^12 bit 4 - 2^11 bit 3 - 2^10 bit 2 - 2^9 bit 1 - 2^8 bit 0 - 2^7 Octet 8 bit 7 - f/u bit 6 - 2^6 Code Violations (CV) bit 5 - 2^5 bit 4 - 2^4 bit 3 - 2^3 bit 2 - 2^2 bit 1 - 2^1 bit 0 - 2^0" ::= { sc800t3PreviousFarEndEntry 2 } -- ******************************************************************** -- GDC Local SC800T3 Alarm Configuration -- ******************************************************************** sc800t3LocalAlarmConfigTable OBJECT-TYPE SYNTAX SEQUENCE OF Sc800t3LocalAlarmConfigEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "The sc800t3LocalAlarmConfigTable contains entries that configure alarm reporting. The structure of the table is such that alarm configuration is supported on a unit and interface basis, and then on an alarm type basis within the interface. For simplicity sake alarms, be they unit or interface related, are represented in one table." ::= { sc800t3LocalAlarms 1 } sc800t3LocalAlarmConfigEntry OBJECT-TYPE SYNTAX Sc800t3LocalAlarmConfigEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "An entry in the GDC Local Alarm Configuration table." INDEX { sc800t3LocalAlarmConfigIndex } ::= { sc800t3LocalAlarmConfigTable 1 } Sc800t3LocalAlarmConfigEntry ::= SEQUENCE { sc800t3LocalAlarmConfigIndex SCinstance, sc800t3OOF INTEGER, sc800t3AISLOCAL INTEGER, sc800t3TIMLOS INTEGER, sc800t3TXDLOS INTEGER, sc800t3RXDLOS INTEGER, sc800t3LOS INTEGER, sc800t3TPSFAIL INTEGER, sc800t3BPSFAIL INTEGER, sc800t3DTECLKLOS INTEGER, sc800t3DTERDYLOS INTEGER, sc800t3RAILOCAL INTEGER, sc800t3THRESHESL INTEGER, sc800t3THRESHES INTEGER, sc800t3THRESHSES INTEGER, sc800t3THRESHSAS INTEGER, sc800t3THRESHUAS INTEGER, sc800t3THRESHCV INTEGER } sc800t3LocalAlarmConfigIndex OBJECT-TYPE SYNTAX SCinstance ACCESS read-only STATUS mandatory DESCRIPTION "The index value which uniquely identifies the interface to which this entry is applicable." ::= { sc800t3LocalAlarmConfigEntry 1 } sc800t3OOF OBJECT-TYPE SYNTAX INTEGER { disabled(1), enabledMajor(2), enabledMinor(3) } ACCESS read-write STATUS mandatory DESCRIPTION "Disables or enables the alarm on the Major buss or Minor buss." ::= { sc800t3LocalAlarmConfigEntry 2 } sc800t3AISLOCAL OBJECT-TYPE SYNTAX INTEGER { disabled(1), enabledMajor(2), enabledMinor(3) } ACCESS read-write STATUS mandatory DESCRIPTION "Disables or enables the alarm on the Major buss or Minor buss." ::= { sc800t3LocalAlarmConfigEntry 3 } sc800t3TIMLOS OBJECT-TYPE SYNTAX INTEGER { disabled(1), enabledMajor(2), enabledMinor(3) } ACCESS read-write STATUS mandatory DESCRIPTION "Disables or enables the alarm on the Major buss or Minor buss." ::= { sc800t3LocalAlarmConfigEntry 4 } sc800t3TXDLOS OBJECT-TYPE SYNTAX INTEGER { disabled(1), enabledMajor(2), enabledMinor(3) } ACCESS read-write STATUS mandatory DESCRIPTION "Disables or enables the alarm on the Major buss or Minor buss." ::= { sc800t3LocalAlarmConfigEntry 5 } sc800t3RXDLOS OBJECT-TYPE SYNTAX INTEGER { disabled(1), enabledMajor(2), enabledMinor(3) } ACCESS read-write STATUS mandatory DESCRIPTION "Disables or enables the alarm on the Major buss or Minor buss." ::= { sc800t3LocalAlarmConfigEntry 6 } sc800t3LOS OBJECT-TYPE SYNTAX INTEGER { disabled(1), enabledMajor(2), enabledMinor(3) } ACCESS read-write STATUS mandatory DESCRIPTION "Disables or enables the alarm on the Major buss or Minor buss." ::= { sc800t3LocalAlarmConfigEntry 7 } sc800t3TPSFAIL OBJECT-TYPE SYNTAX INTEGER { disabled(1), enabledMajor(2), enabledMinor(3) } ACCESS read-write STATUS mandatory DESCRIPTION "Disables or enables the alarm on the Major buss or Minor buss." ::= { sc800t3LocalAlarmConfigEntry 8 } sc800t3BPSFAIL OBJECT-TYPE SYNTAX INTEGER { disabled(1), enabledMajor(2), enabledMinor(3) } ACCESS read-write STATUS mandatory DESCRIPTION "Disables or enables the alarm on the Major buss or Minor buss." ::= { sc800t3LocalAlarmConfigEntry 9 } sc800t3DTECLKLOS OBJECT-TYPE SYNTAX INTEGER { disabled(1), enabledMajor(2), enabledMinor(3) } ACCESS read-write STATUS mandatory DESCRIPTION "Disables or enables the alarm on the Major buss or Minor buss." ::= { sc800t3LocalAlarmConfigEntry 10 } sc800t3DTERDYLOS OBJECT-TYPE SYNTAX INTEGER { disabled(1), enabledMajor(2), enabledMinor(3) } ACCESS read-write STATUS mandatory DESCRIPTION "Disables or enables the alarm on the Major buss or Minor buss." ::= { sc800t3LocalAlarmConfigEntry 11 } sc800t3RAILOCAL OBJECT-TYPE SYNTAX INTEGER { disabled(1), enabledMajor(2), enabledMinor(3) } ACCESS read-write STATUS mandatory DESCRIPTION "Disables or enables the alarm on the Major buss or Minor buss." ::= { sc800t3LocalAlarmConfigEntry 12 } sc800t3THRESHESL OBJECT-TYPE SYNTAX INTEGER { disabled(1), enabledMajor(2), enabledMinor(3) } ACCESS read-write STATUS mandatory DESCRIPTION "Disables or enables the alarm on the Major buss or Minor buss." ::= { sc800t3LocalAlarmConfigEntry 13 } sc800t3THRESHES OBJECT-TYPE SYNTAX INTEGER { disabled(1), enabledMajor(2), enabledMinor(3) } ACCESS read-write STATUS mandatory DESCRIPTION "Disables or enables the alarm on the Major buss or Minor buss." ::= { sc800t3LocalAlarmConfigEntry 14 } sc800t3THRESHSES OBJECT-TYPE SYNTAX INTEGER { disabled(1), enabledMajor(2), enabledMinor(3) } ACCESS read-write STATUS mandatory DESCRIPTION "Disables or enables the alarm on the Major buss or Minor buss." ::= { sc800t3LocalAlarmConfigEntry 15 } sc800t3THRESHSAS OBJECT-TYPE SYNTAX INTEGER { disabled(1), enabledMajor(2), enabledMinor(3) } ACCESS read-write STATUS mandatory DESCRIPTION "Disables or enables the alarm on the Major buss or Minor buss." ::= { sc800t3LocalAlarmConfigEntry 16 } sc800t3THRESHUAS OBJECT-TYPE SYNTAX INTEGER { disabled(1), enabledMajor(2), enabledMinor(3) } ACCESS read-write STATUS mandatory DESCRIPTION "Disables or enables the alarm on the Major buss or Minor buss." ::= { sc800t3LocalAlarmConfigEntry 17 } sc800t3THRESHCV OBJECT-TYPE SYNTAX INTEGER { disabled(1), enabledMajor(2), enabledMinor(3) } ACCESS read-write STATUS mandatory DESCRIPTION "Disables or enables the alarm on the Major buss or Minor buss." ::= { sc800t3LocalAlarmConfigEntry 18 } -- **************************************************************************** -- mib definitions end -- **************************************************************************** END