All MIBs › GDC-SC800T3-MIB › sc800t3ForcedDCE
sc800t3ForcedDCE
Module: GDC-SC800T3-MIB
OID (symbolic): GDC-SC800T3-MIB::sc800t3ForcedDCE
OID (numeric): 1.3.6.1.4.1.498.19.1.2.1.1.2
Node type: OBJECT-TYPE
Type: INTEGER
Access: read-write
Description: Controls the operation of Data Communications Equipment (DCE) signal. The value followsDte(1) indicates that the channel's DCE follows Data Terminal Equipment (DTE) ready. The value forcedOn(2) indicates that DCE is forced on.
What is sc800t3ForcedDCE?
Controls whether the channel's DCE-ready signal simply tracks the DTE-ready state (followsDte) or is forced permanently on (forcedOn), overriding the attached terminal equipment. Admins force it on when testing or when the connected DTE's ready signal is unreliable.
Examples
Walk all instances (SNMPv2c):
snmpwalk -v2c -c public <target> 1.3.6.1.4.1.498.19.1.2.1.1.2 snmpwalk -v2c -c public <target> GDC-SC800T3-MIB::sc800t3ForcedDCE
Get a specific instance (index 1):
snmpget -v2c -c public <target> 1.3.6.1.4.1.498.19.1.2.1.1.2.1 snmpget -v2c -c public <target> GDC-SC800T3-MIB::sc800t3ForcedDCE.1
Set instance 1 (SNMPv2c):
snmpset -v2c -c private <target> 1.3.6.1.4.1.498.19.1.2.1.1.2.1 i <value>
SNMPv3 example:
snmpget -v3 -l authPriv -u snmpv3-user -a SHA -A "AuthPassword1" -x AES -X "PrivPassword1" <target> sc800t3ForcedDCE.1
Start monitoring General DataComm (GDC) SC800 T3 channel-service unit with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the GDC-SC800T3-MIB::sc800t3ForcedDCE OID value, configure state conditions and alerts, and monitor any General DataComm (GDC) SC800 T3 channel-service unit from a single console.
OID Breakdown
Upper-level ancestors (7 from the standard OID tree / other modules)
| Numeric OID | Name | Module |
|---|---|---|
| 1 | iso | LANART-AGENT |
| 1.3 | org | AirPair-MIB |
| 1.3.6 | dod | AirPair-MIB |
| 1.3.6.1 | internet | AirPair-MIB |
| 1.3.6.1.4 | private | AirPair-MIB |
| 1.3.6.1.4.1 | enterprises | AirPair-MIB |
| 1.3.6.1.4.1.498 | gdc | GDC7616-MIB |
| Numeric OID | Name | Module |
|---|---|---|
| 1.3.6.1.4.1.498.19 | ds3 | GDC-SC800T3-MIB |
| 1.3.6.1.4.1.498.19.1 | sc800t3 | GDC-SC800T3-MIB |
| 1.3.6.1.4.1.498.19.1.2 | sc800t3Configuration | GDC-SC800T3-MIB |
| 1.3.6.1.4.1.498.19.1.2.1 | sc800t3ChannelConfigTable | GDC-SC800T3-MIB |
| 1.3.6.1.4.1.498.19.1.2.1.1 | sc800t3ChannelConfigEntry | GDC-SC800T3-MIB |
| 1.3.6.1.4.1.498.19.1.2.1.1.2 | sc800t3ForcedDCE | GDC-SC800T3-MIB |