All MIBs › GDC-SC800T3-MIB › sc800t3FarEndResetStats
sc800t3FarEndResetStats
Module: GDC-SC800T3-MIB
OID (symbolic): GDC-SC800T3-MIB::sc800t3FarEndResetStats
OID (numeric): 1.3.6.1.4.1.498.19.1.4.1.1.11
Node type: OBJECT-TYPE
Type: INTEGER
Access: read-write
Description: Supports the action of soft resetting the sc800t3ValidFarEndIntervals object. When this object is set to reset(2), then the unit will reset the sc800t3ValidFarEndIntervals object to zero. The value of norm(1) can not be set by management.
What is sc800t3FarEndResetStats?
Setting this to reset(2) zeroes out the sc800t3ValidFarEndIntervals counter, clearing the far-end 15-minute performance history; norm(1) cannot be set directly. Admins use it alongside sc800t3NearEndResetStats to reset both directions' baselines together.
Examples
Walk all instances (SNMPv2c):
snmpwalk -v2c -c public <target> 1.3.6.1.4.1.498.19.1.4.1.1.11 snmpwalk -v2c -c public <target> GDC-SC800T3-MIB::sc800t3FarEndResetStats
Get a specific instance (index 1):
snmpget -v2c -c public <target> 1.3.6.1.4.1.498.19.1.4.1.1.11.1 snmpget -v2c -c public <target> GDC-SC800T3-MIB::sc800t3FarEndResetStats.1
Set instance 1 (SNMPv2c):
snmpset -v2c -c private <target> 1.3.6.1.4.1.498.19.1.4.1.1.11.1 i <value>
SNMPv3 example:
snmpget -v3 -l authPriv -u snmpv3-user -a SHA -A "AuthPassword1" -x AES -X "PrivPassword1" <target> sc800t3FarEndResetStats.1
Start monitoring General DataComm (GDC) SC800 T3 channel-service unit with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the GDC-SC800T3-MIB::sc800t3FarEndResetStats OID value, configure state conditions and alerts, and monitor any General DataComm (GDC) SC800 T3 channel-service unit from a single console.
OID Breakdown
Upper-level ancestors (7 from the standard OID tree / other modules)
| Numeric OID | Name | Module |
|---|---|---|
| 1 | iso | LANART-AGENT |
| 1.3 | org | AirPair-MIB |
| 1.3.6 | dod | AirPair-MIB |
| 1.3.6.1 | internet | AirPair-MIB |
| 1.3.6.1.4 | private | AirPair-MIB |
| 1.3.6.1.4.1 | enterprises | AirPair-MIB |
| 1.3.6.1.4.1.498 | gdc | GDC7616-MIB |
| Numeric OID | Name | Module |
|---|---|---|
| 1.3.6.1.4.1.498.19 | ds3 | GDC-SC800T3-MIB |
| 1.3.6.1.4.1.498.19.1 | sc800t3 | GDC-SC800T3-MIB |
| 1.3.6.1.4.1.498.19.1.4 | sc800t3Maintenance | GDC-SC800T3-MIB |
| 1.3.6.1.4.1.498.19.1.4.1 | sc800t3MaintenanceTable | GDC-SC800T3-MIB |
| 1.3.6.1.4.1.498.19.1.4.1.1 | sc800t3MaintenanceEntry | GDC-SC800T3-MIB |
| 1.3.6.1.4.1.498.19.1.4.1.1.11 | sc800t3FarEndResetStats | GDC-SC800T3-MIB |