FSC-RTP-MIB-ALARM-MGMT :: rtpArmAlarmObjectAction

MIB Reference — IPNetwork Monitor · Updated October 05, 2026

All MIBs › FSC-RTP-MIB-ALARM-MGMT › rtpArmAlarmObjectAction

rtpArmAlarmObjectAction

Module: FSC-RTP-MIB-ALARM-MGMT

OID (symbolic): FSC-RTP-MIB-ALARM-MGMT::rtpArmAlarmObjectAction

OID (numeric): 1.3.6.1.4.1.4329.2.1.2.2.1.1.1.3

Node type: OBJECT-TYPE

Type: INTEGER

Access: read-write

Description: Get requests will always return 'nothing'.

Setting this object to 'clear' clears the indexed alarm object by removing all related alarms; the related conceptual rows in 'rtpArmAlarmTable' are removed.

Setting this object to 'nothing' has no effect.

What is rtpArmAlarmObjectAction?

This read-write control lets an admin clear all active alarms belonging to the indexed Alarm Object type by setting it to clear(1); a GET always returns nothing(0). It's the mechanism for bulk-dismissing every related row in rtpArmAlarmTable for that alarm type in one SNMP SET, rather than deleting entries individually. For example, setting rtpArmAlarmObjectAction to clear(1) on a power-supply alarm-object row removes every currently active power-supply alarm from the alarm table at once.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.4329.2.1.2.2.1.1.1.3
snmpwalk -v2c -c public <target> FSC-RTP-MIB-ALARM-MGMT::rtpArmAlarmObjectAction

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.4329.2.1.2.2.1.1.1.3.1
snmpget -v2c -c public <target> FSC-RTP-MIB-ALARM-MGMT::rtpArmAlarmObjectAction.1

Set instance 1 (SNMPv2c):

snmpset -v2c -c private <target> 1.3.6.1.4.1.4329.2.1.2.2.1.1.1.3.1 i <value>

Start monitoring Fujitsu Siemens HiPath 8000 telecom server (Resilient Telco Platform) (alarm management) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the FSC-RTP-MIB-ALARM-MGMT::rtpArmAlarmObjectAction OID value, configure state conditions and alerts, and monitor any Fujitsu Siemens HiPath 8000 telecom server (Resilient Telco Platform) (alarm management) from a single console.

OID Breakdown

Upper-level ancestors (10 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.4329siemensFSC-RTP-MIB
1.3.6.1.4.1.4329.2iandcAdminFSC-RTP-MIB
1.3.6.1.4.1.4329.2.1rtpFSC-RTP-MIB
1.3.6.1.4.1.4329.2.1.2rtpFaultMgmtFSC-RTP-MIB
Numeric OIDNameModule
1.3.6.1.4.1.4329.2.1.2.2rtpAlarmMgmtModuleFSC-RTP-MIB-ALARM-MGMT
1.3.6.1.4.1.4329.2.1.2.2.1rtpAlarmMgmtFSC-RTP-MIB-ALARM-MGMT
1.3.6.1.4.1.4329.2.1.2.2.1.1rtpArmAlarmObjectTableFSC-RTP-MIB-ALARM-MGMT
1.3.6.1.4.1.4329.2.1.2.2.1.1.1rtpArmAlarmObjectEntryFSC-RTP-MIB-ALARM-MGMT
1.3.6.1.4.1.4329.2.1.2.2.1.1.1.3rtpArmAlarmObjectActionFSC-RTP-MIB-ALARM-MGMT