FSC-RTP-MIB-ALARM-MGMT :: rtpArmAlarmAction

MIB Reference — IPNetwork Monitor · Updated October 05, 2026

All MIBs › FSC-RTP-MIB-ALARM-MGMT › rtpArmAlarmAction

rtpArmAlarmAction

Module: FSC-RTP-MIB-ALARM-MGMT

OID (symbolic): FSC-RTP-MIB-ALARM-MGMT::rtpArmAlarmAction

OID (numeric): 1.3.6.1.4.1.4329.2.1.2.2.1.2.1.4

Node type: OBJECT-TYPE

Type: INTEGER

Access: read-write

Description: Get requests will always return 'nothing'.

Setting this object to one of the specified actions has the following effects:

deleteSingle: Deletes a single entry selected by its current Id (rtpArmAlarmId) from the alarm table. rtpArmAlarmType and rtpArmAlarmTime should be set to zero or to valid values (i.e. an existing OID).

deleteBeforeId: Deletes all entries within the specified alarm type from the top of the alarm table to the set current Id (rtpArmAlarmId) from the alarm table. rtpArmAlarmTime should be set to zero or to a valid value (i.e. an existing OID).

deleteBeforeTime: Deletes all entries within the specified alarm type from the top of the alarm table to the set alarm time (rtpArmAlarmTime) from the alarm table. rtpArmAlarmId must be set to a valid value (i.e. an existing OID).

Setting this object to 'nothing' has no effect.

What is rtpArmAlarmAction?

This read-write control lets an admin remove entries from the active alarm table by ID or by time cutoff, supporting deleteSingle, deleteBeforeId, and deleteBeforeTime actions in addition to a no-op nothing(0), which a GET always returns. It gives fine-grained cleanup options beyond the bulk clear offered by rtpArmAlarmObjectAction, such as clearing every alarm of a given type up to a specific alarm ID or timestamp. For instance, setting this to deleteBeforeTime while rtpArmAlarmType and rtpArmAlarmId are set to valid values purges all older alarms of that type up to the specified rtpArmAlarmTime.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.4329.2.1.2.2.1.2.1.4
snmpwalk -v2c -c public <target> FSC-RTP-MIB-ALARM-MGMT::rtpArmAlarmAction

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.4329.2.1.2.2.1.2.1.4.1
snmpget -v2c -c public <target> FSC-RTP-MIB-ALARM-MGMT::rtpArmAlarmAction.1

Set instance 1 (SNMPv2c):

snmpset -v2c -c private <target> 1.3.6.1.4.1.4329.2.1.2.2.1.2.1.4.1 i <value>

Start monitoring Fujitsu Siemens HiPath 8000 telecom server (Resilient Telco Platform) (alarm management) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the FSC-RTP-MIB-ALARM-MGMT::rtpArmAlarmAction OID value, configure state conditions and alerts, and monitor any Fujitsu Siemens HiPath 8000 telecom server (Resilient Telco Platform) (alarm management) from a single console.

OID Breakdown

Upper-level ancestors (10 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.4329siemensFSC-RTP-MIB
1.3.6.1.4.1.4329.2iandcAdminFSC-RTP-MIB
1.3.6.1.4.1.4329.2.1rtpFSC-RTP-MIB
1.3.6.1.4.1.4329.2.1.2rtpFaultMgmtFSC-RTP-MIB
Numeric OIDNameModule
1.3.6.1.4.1.4329.2.1.2.2rtpAlarmMgmtModuleFSC-RTP-MIB-ALARM-MGMT
1.3.6.1.4.1.4329.2.1.2.2.1rtpAlarmMgmtFSC-RTP-MIB-ALARM-MGMT
1.3.6.1.4.1.4329.2.1.2.2.1.2rtpArmAlarmTableFSC-RTP-MIB-ALARM-MGMT
1.3.6.1.4.1.4329.2.1.2.2.1.2.1rtpArmAlarmEntryFSC-RTP-MIB-ALARM-MGMT
1.3.6.1.4.1.4329.2.1.2.2.1.2.1.4rtpArmAlarmActionFSC-RTP-MIB-ALARM-MGMT