All MIBs › FSC-HPI-MIB › hpiHotSwapIndicator
hpiHotSwapIndicator
Module: FSC-HPI-MIB
OID (symbolic): FSC-HPI-MIB::hpiHotSwapIndicator
OID (numeric): 1.3.6.1.4.1.231.2.60.6.2.11.3.1.2
Node type: OBJECT-TYPE
Type: INTEGER
Access: read-write
Description: A FRU associated with a hot-swappable resource may include a hot swap indicator such as a blue LED. This indicator signifies that the FRU is ready for removal. This columnar node allows the HPI SNMP Manager to retrieve and set the state of this indicator. When retrieving the values, the valid states are either hpiHotSwapIndicator == off(1) or hpiHotSwapIndicator == on(2). This columnar node will return information, regardless of what hot swap state the resource is in. When setting the values, valid states include hpiHotSwapIndicator == off(1) or hpiHotSwapIndicator == on(2). This function will set the indicator regardless of what hot swap state the resource is in, though it is recommended that this function be used only in conjunction with moving the resource to the appropriate hot swap state.
Examples
Walk all instances (SNMPv2c):
snmpwalk -v2c -c public <target> 1.3.6.1.4.1.231.2.60.6.2.11.3.1.2 snmpwalk -v2c -c public <target> FSC-HPI-MIB::hpiHotSwapIndicator
Get a specific instance (index 1):
snmpget -v2c -c public <target> 1.3.6.1.4.1.231.2.60.6.2.11.3.1.2.1 snmpget -v2c -c public <target> FSC-HPI-MIB::hpiHotSwapIndicator.1
Set instance 1 (SNMPv2c):
snmpset -v2c -c private <target> 1.3.6.1.4.1.231.2.60.6.2.11.3.1.2.1 i <value>
Start monitoring Fujitsu Siemens PRIMERGY servers with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the FSC-HPI-MIB::hpiHotSwapIndicator OID value, configure state conditions and alerts, and monitor any Fujitsu Siemens PRIMERGY servers from a single console.
OID Breakdown
Upper-level ancestors (9 from the standard OID tree / other modules)
| Numeric OID | Name | Module |
|---|---|---|
| 1 | iso | LANART-AGENT |
| 1.3 | org | AirPair-MIB |
| 1.3.6 | dod | AirPair-MIB |
| 1.3.6.1 | internet | AirPair-MIB |
| 1.3.6.1.4 | private | AirPair-MIB |
| 1.3.6.1.4.1 | enterprises | AirPair-MIB |
| 1.3.6.1.4.1.231 | sni | AN-MIB |
| 1.3.6.1.4.1.231.2 | sniProductMibs | Application-Monitoring-MIB |
| 1.3.6.1.4.1.231.2.60 | fscHpi | FSC-AC-MIB |
| Numeric OID | Name | Module |
|---|---|---|
| 1.3.6.1.4.1.231.2.60.6 | fscHpiBMIB | FSC-HPI-MIB |
| 1.3.6.1.4.1.231.2.60.6.2 | hpiDomain | FSC-HPI-MIB |
| 1.3.6.1.4.1.231.2.60.6.2.11 | hpiHotSwap | FSC-HPI-MIB |
| 1.3.6.1.4.1.231.2.60.6.2.11.3 | hpiHotSwapTable | FSC-HPI-MIB |
| 1.3.6.1.4.1.231.2.60.6.2.11.3.1 | hpiHotSwapEntry | FSC-HPI-MIB |
| 1.3.6.1.4.1.231.2.60.6.2.11.3.1.2 | hpiHotSwapIndicator | FSC-HPI-MIB |