FSC-HPI-MIB :: hpiHotSwapExtractTimeout

MIB Reference — IPNetwork Monitor · Updated October 02, 2026

All MIBs › FSC-HPI-MIB › hpiHotSwapExtractTimeout

hpiHotSwapExtractTimeout

Module: FSC-HPI-MIB

OID (symbolic): FSC-HPI-MIB::hpiHotSwapExtractTimeout

OID (numeric): 1.3.6.1.4.1.231.2.60.6.2.11.3.1.4

Node type: OBJECT-TYPE

Type: SaHpiTime

Access: read-write

Description: This function allows the HPI User to configure a timeout for how long to wait before the default auto-extraction policy is invoked. This function accepts a parameter instructing the resource to impose a delay before performing its default hot swap policy for auto-extraction. The parameter may be set to SAHPI_TIMEOUT_IMMEDIATE to direct the resource to proceed immediately to auto-extraction, or to SAHPI_TIMEOUT_BLOCK to prevent auto-extraction from ever occurring on a resource. If the parameter is set to another value, then it defines the number of nanoseconds between the time a hot swap event with hpiHotSwapState = extractionPending(5) is generated and the time that the auto-extraction policy will be invoked for the resource. If, during this time period, a hpiHotSwapPolicyCancel function call is processed, the timer will be stopped, and the auto-extraction policy will not be invoked.

Once the auto-extraction process begins, the HPI User will not be allowed to take control of the extraction process; hence, the timeout should be set appropriately to allow for this condition.

Note that the timeout period begins when the hot swap event with hpiHotSwapState = extractionPending(4) is initially generated.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.231.2.60.6.2.11.3.1.4
snmpwalk -v2c -c public <target> FSC-HPI-MIB::hpiHotSwapExtractTimeout

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.231.2.60.6.2.11.3.1.4.1
snmpget -v2c -c public <target> FSC-HPI-MIB::hpiHotSwapExtractTimeout.1

Set instance 1 (SNMPv2c):

snmpset -v2c -c private <target> 1.3.6.1.4.1.231.2.60.6.2.11.3.1.4.1 s <value>

Start monitoring Fujitsu Siemens PRIMERGY servers with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the FSC-HPI-MIB::hpiHotSwapExtractTimeout OID value, configure state conditions and alerts, and monitor any Fujitsu Siemens PRIMERGY servers from a single console.

OID Breakdown

Upper-level ancestors (9 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.231sniAN-MIB
1.3.6.1.4.1.231.2sniProductMibsApplication-Monitoring-MIB
1.3.6.1.4.1.231.2.60fscHpiFSC-AC-MIB
Numeric OIDNameModule
1.3.6.1.4.1.231.2.60.6fscHpiBMIBFSC-HPI-MIB
1.3.6.1.4.1.231.2.60.6.2hpiDomainFSC-HPI-MIB
1.3.6.1.4.1.231.2.60.6.2.11hpiHotSwapFSC-HPI-MIB
1.3.6.1.4.1.231.2.60.6.2.11.3hpiHotSwapTableFSC-HPI-MIB
1.3.6.1.4.1.231.2.60.6.2.11.3.1hpiHotSwapEntryFSC-HPI-MIB
1.3.6.1.4.1.231.2.60.6.2.11.3.1.4hpiHotSwapExtractTimeoutFSC-HPI-MIB