Module: FRDCE-OPT-MIB

OID (symbolic): FRDCE-OPT-MIB::cdx6500frdcepPortSpeed

OID (numeric): 1.3.6.1.4.1.449.2.1.3.1.1.6.1.3

Node type: OBJECT-TYPE

Type: INTEGER

Access: read-only

Description: This is the speed of the port if clock is internal. If clock is external, this is the detected clock speed. If Port Speed is 0, clock is external, but clocking is not being received from attatched device.

What is cdx6500frdcepPortSpeed?

Reports the port's actual line speed: the configured value if clocking is internal, or the detected incoming clock rate if external; a value of 0 with external clocking means no clock signal is being received from the attached device.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.449.2.1.3.1.1.6.1.3
snmpwalk -v2c -c public <target> FRDCE-OPT-MIB::cdx6500frdcepPortSpeed

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.449.2.1.3.1.1.6.1.3.1
snmpget -v2c -c public <target> FRDCE-OPT-MIB::cdx6500frdcepPortSpeed.1

Start monitoring Codex CDX-6500 Frame Relay access device (DCE/network side) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the FRDCE-OPT-MIB::cdx6500frdcepPortSpeed OID value, configure state conditions and alerts, and monitor any Codex CDX-6500 Frame Relay access device (DCE/network side) from a single console.

OID Breakdown

Upper-level ancestors (12 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.449codexALC-OPT-MIB
1.3.6.1.4.1.449.2cdxProductSpecificALC-OPT-MIB
1.3.6.1.4.1.449.2.1cdx6500ALC-OPT-MIB
1.3.6.1.4.1.449.2.1.3cdx6500StatisticsALC-OPT-MIB
1.3.6.1.4.1.449.2.1.3.1cdx6500StatProtocolGroupALC-OPT-MIB
1.3.6.1.4.1.449.2.1.3.1.1cdx6500PSTPortProtocolGroupALC-OPT-MIB
Numeric OIDNameModule
1.3.6.1.4.1.449.2.1.3.1.1.6cdx6500PPSTFRDCEPortTableFRDCE-OPT-MIB
1.3.6.1.4.1.449.2.1.3.1.1.6.1cdx6500PPSTFRDCEPortEntryFRDCE-OPT-MIB
1.3.6.1.4.1.449.2.1.3.1.1.6.1.3cdx6500frdcepPortSpeedFRDCE-OPT-MIB