All MIBs › FRDCE-OPT-MIB › cdx6500frdcepN392
cdx6500frdcepN392
Module: FRDCE-OPT-MIB
OID (symbolic): FRDCE-OPT-MIB::cdx6500frdcepN392
OID (numeric): 1.3.6.1.4.1.449.2.1.2.1.1.6.1.10
Node type: OBJECT-TYPE
Type: INTEGER
Access: read-only
Description: This parameter is the Error Inactivity Threshold. The data link is declared to be up after receiving N392/nN2 consecutive events without error. The data link is declared to be down when any N392/nN2 of the previous N393/nN3 events were received in error. This parameter must be set to a value less than or equal to N393/nN3.
What is cdx6500frdcepN392?
Reports the Error Inactivity Threshold (N392): the link is declared up after N392 consecutive error-free events and declared down if N392 of the last N393 events were errors; must not exceed N393.
Examples
Walk all instances (SNMPv2c):
snmpwalk -v2c -c public <target> 1.3.6.1.4.1.449.2.1.2.1.1.6.1.10 snmpwalk -v2c -c public <target> FRDCE-OPT-MIB::cdx6500frdcepN392
Get a specific instance (index 1):
snmpget -v2c -c public <target> 1.3.6.1.4.1.449.2.1.2.1.1.6.1.10.1 snmpget -v2c -c public <target> FRDCE-OPT-MIB::cdx6500frdcepN392.1
Start monitoring Codex CDX-6500 Frame Relay access device (DCE/network side) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the FRDCE-OPT-MIB::cdx6500frdcepN392 OID value, configure state conditions and alerts, and monitor any Codex CDX-6500 Frame Relay access device (DCE/network side) from a single console.
OID Breakdown
Upper-level ancestors (12 from the standard OID tree / other modules)
| Numeric OID | Name | Module |
|---|---|---|
| 1 | iso | LANART-AGENT |
| 1.3 | org | AirPair-MIB |
| 1.3.6 | dod | AirPair-MIB |
| 1.3.6.1 | internet | AirPair-MIB |
| 1.3.6.1.4 | private | AirPair-MIB |
| 1.3.6.1.4.1 | enterprises | AirPair-MIB |
| 1.3.6.1.4.1.449 | codex | ALC-OPT-MIB |
| 1.3.6.1.4.1.449.2 | cdxProductSpecific | ALC-OPT-MIB |
| 1.3.6.1.4.1.449.2.1 | cdx6500 | ALC-OPT-MIB |
| 1.3.6.1.4.1.449.2.1.2 | cdx6500Configuration | ALC-OPT-MIB |
| 1.3.6.1.4.1.449.2.1.2.1 | cdx6500CfgProtocolGroup | ALC-OPT-MIB |
| 1.3.6.1.4.1.449.2.1.2.1.1 | cdx6500PCTPortProtocolGroup | ALC-OPT-MIB |
| Numeric OID | Name | Module |
|---|---|---|
| 1.3.6.1.4.1.449.2.1.2.1.1.6 | cdx6500PCTFRDCEPortTable | FRDCE-OPT-MIB |
| 1.3.6.1.4.1.449.2.1.2.1.1.6.1 | cdx6500PCTFRDCEPortEntry | FRDCE-OPT-MIB |
| 1.3.6.1.4.1.449.2.1.2.1.1.6.1.10 | cdx6500frdcepN392 | FRDCE-OPT-MIB |