FRDCE-OPT-MIB :: cdx6500frdcepCtrlProtocol

MIB Reference — IPNetwork Monitor · Updated October 05, 2026

All MIBs › FRDCE-OPT-MIB › cdx6500frdcepCtrlProtocol

cdx6500frdcepCtrlProtocol

Module: FRDCE-OPT-MIB

OID (symbolic): FRDCE-OPT-MIB::cdx6500frdcepCtrlProtocol

OID (numeric): 1.3.6.1.4.1.449.2.1.2.1.1.6.1.6

Node type: OBJECT-TYPE

Type: INTEGER

Access: read-only

Description: Whether ANSI T1.617 Annex D or LMI Support is enabled none - None is enabled. annexD - Annex D is enabled. lmi - LMI is enabled. annexA - Annex A is enabled. newvalAnnexD - same functionality as 'annexD', new enumeration added for RFC1155 compatibility.

What is cdx6500frdcepCtrlProtocol?

Indicates which link-management protocol this port uses to exchange PVC status with the network - ANSI T1.617 Annex D, LMI, Annex A, or none - which must match what the far-end switch expects.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.449.2.1.2.1.1.6.1.6
snmpwalk -v2c -c public <target> FRDCE-OPT-MIB::cdx6500frdcepCtrlProtocol

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.449.2.1.2.1.1.6.1.6.1
snmpget -v2c -c public <target> FRDCE-OPT-MIB::cdx6500frdcepCtrlProtocol.1

Start monitoring Codex CDX-6500 Frame Relay access device (DCE/network side) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the FRDCE-OPT-MIB::cdx6500frdcepCtrlProtocol OID value, configure state conditions and alerts, and monitor any Codex CDX-6500 Frame Relay access device (DCE/network side) from a single console.

OID Breakdown

Upper-level ancestors (12 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.449codexALC-OPT-MIB
1.3.6.1.4.1.449.2cdxProductSpecificALC-OPT-MIB
1.3.6.1.4.1.449.2.1cdx6500ALC-OPT-MIB
1.3.6.1.4.1.449.2.1.2cdx6500ConfigurationALC-OPT-MIB
1.3.6.1.4.1.449.2.1.2.1cdx6500CfgProtocolGroupALC-OPT-MIB
1.3.6.1.4.1.449.2.1.2.1.1cdx6500PCTPortProtocolGroupALC-OPT-MIB
Numeric OIDNameModule
1.3.6.1.4.1.449.2.1.2.1.1.6cdx6500PCTFRDCEPortTableFRDCE-OPT-MIB
1.3.6.1.4.1.449.2.1.2.1.1.6.1cdx6500PCTFRDCEPortEntryFRDCE-OPT-MIB