FOUNDRY-SN-VSRP-MIB :: snVsrpVirRtrRxArpPktDropCnts

MIB Reference — IPNetwork Monitor · Updated October 05, 2026

All MIBs › FOUNDRY-SN-VSRP-MIB › snVsrpVirRtrRxArpPktDropCnts

snVsrpVirRtrRxArpPktDropCnts

Module: FOUNDRY-SN-VSRP-MIB

OID (symbolic): FOUNDRY-SN-VSRP-MIB::snVsrpVirRtrRxArpPktDropCnts

OID (numeric): 1.3.6.1.4.1.1991.1.1.3.21.3.1.1.21

Node type: OBJECT-TYPE

Type: Counter32

Access: read-only

Description: The received vsrp ARP Packet Drop Counts.

What is snVsrpVirRtrRxArpPktDropCnts?

A running count of ARP packets this virtual router has dropped, which an admin can watch alongside the other Rx*Cnts counters to spot a misconfigured neighbor sending malformed VSRP-related ARP traffic.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.1991.1.1.3.21.3.1.1.21
snmpwalk -v2c -c public <target> FOUNDRY-SN-VSRP-MIB::snVsrpVirRtrRxArpPktDropCnts

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.1991.1.1.3.21.3.1.1.21.1
snmpget -v2c -c public <target> FOUNDRY-SN-VSRP-MIB::snVsrpVirRtrRxArpPktDropCnts.1

Start monitoring Brocade/Foundry NetIron/FastIron/BigIron switch/router (VSRP gateway redundancy) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the FOUNDRY-SN-VSRP-MIB::snVsrpVirRtrRxArpPktDropCnts OID value, configure state conditions and alerts, and monitor any Brocade/Foundry NetIron/FastIron/BigIron switch/router (VSRP gateway redundancy) from a single console.

How to Use in IPNetwork Monitor

Select a Brocade/Foundry NetIron/FastIron/BigIron switch/router (VSRP gateway redundancy) as the target host to create a monitor — the SNMP service should be up and running on it. Click New Monitor, then check SNMP Custom on the Favorites tab, click Next, and confirm the host. On the next page, click Select... to open the built-in SNMP MIB Browser and type snVsrpVirRtrRxArpPktDropCnts into the Find box to locate it in the OID tree, selecting the specific row/instance you want to monitor since this is a table column, then select it and click OK. The received vsrp ARP Packet Drop Counts. On the monitor's Main parameters page you can set the target's SNMP port (default 161), credentials, polling interval, and other settings — see the SNMP Monitor help for details. On the State conditions and Alerting tabs, configure when the monitor should change state and trigger an alert; since this is a Counter32-type OID, Value bounds is the most useful condition here — trigger an alert if the counter increases between polls, since a rising count of errors, failures, or discards often points to a real underlying problem. Click Finish to create the monitor; you can adjust any parameter later.

OID Breakdown

Upper-level ancestors (11 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.1991foundryFOUNDRY-SN-ROOT-MIB
1.3.6.1.4.1.1991.1productsFOUNDRY-SN-ROOT-MIB
1.3.6.1.4.1.1991.1.1switchFOUNDRY-SN-ROOT-MIB
1.3.6.1.4.1.1991.1.1.3snSwitchFOUNDRY-SN-ROOT-MIB
1.3.6.1.4.1.1991.1.1.3.21snVsrpFOUNDRY-SN-SWITCH-GROUP-MIB
Numeric OIDNameModule
1.3.6.1.4.1.1991.1.1.3.21.3snVsrpVirRtrFOUNDRY-SN-VSRP-MIB
1.3.6.1.4.1.1991.1.1.3.21.3.1snVsrpVirRtrTableFOUNDRY-SN-VSRP-MIB
1.3.6.1.4.1.1991.1.1.3.21.3.1.1snVsrpVirRtrEntryFOUNDRY-SN-VSRP-MIB
1.3.6.1.4.1.1991.1.1.3.21.3.1.1.21snVsrpVirRtrRxArpPktDropCntsFOUNDRY-SN-VSRP-MIB