FLOW-METER-MIB :: flowManagerCurrentRuleSet

MIB Reference — IPNetwork Monitor · Updated September 14, 2026

All MIBsFLOW-METER-MIBflowManagerCurrentRuleSet

flowManagerCurrentRuleSet

Module: FLOW-METER-MIB

OID (symbolic): FLOW-METER-MIB::flowManagerCurrentRuleSet

OID (numeric): 1.3.6.1.2.1.40.1.4.1.2

Node type: OBJECT-TYPE

Type: Integer32

Access: read-create

Description: Index to the array of RuleSets. Specifies which set of rules is the 'current' one for this task. The meter will be 'running' the current RuleSet if this row's flowManagerRunningStandby value is false(2).

When the manager sets this variable the meter will stop using the task's old current RuleSet and start using the new one. Specifying RuleSet 0 (the empty set) stops flow measurement for this task.

What is flowManagerCurrentRuleSet?

Selects which RuleSet is currently 'running' for this management task; the meter switches from the old current RuleSet to the new one as soon as this is set, and setting it to 0 stops flow measurement for the task entirely.

OID Breakdown

Upper-level ancestors (6 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.2mgmtAXON-MIB
1.3.6.1.2.1mib_2AXON-MIB
Numeric OIDNameModule
1.3.6.1.2.1.40flowMIBFLOW-METER-MIB
1.3.6.1.2.1.40.1flowControlFLOW-METER-MIB
1.3.6.1.2.1.40.1.4flowManagerInfoTableFLOW-METER-MIB
1.3.6.1.2.1.40.1.4.1flowManagerInfoEntryFLOW-METER-MIB
1.3.6.1.2.1.40.1.4.1.2flowManagerCurrentRuleSetFLOW-METER-MIB