All MIBs › FDRY-POE-MIB › snAgentPoePortConsumed
snAgentPoePortConsumed
Module: FDRY-POE-MIB
OID (symbolic): FDRY-POE-MIB::snAgentPoePortConsumed
OID (numeric): 1.3.6.1.4.1.1991.1.1.2.14.2.2.1.6
Node type: OBJECT-TYPE
Type: Integer32
Access: read-only
Description: Inline power consumed by the port. Each unit is milliwatts.
What is snAgentPoePortConsumed?
This Integer32, in milliwatts, reports the amount of inline power currently being drawn by the device connected to this port. Admins monitor it to see real-time PoE usage per port and to track down which devices are consuming the most of the switch's power budget. For example, a reading of 12900 on a port would indicate the connected device is drawing close to the 802.3at class-4 power limit.
Examples
Walk all instances (SNMPv2c):
snmpwalk -v2c -c public <target> 1.3.6.1.4.1.1991.1.1.2.14.2.2.1.6 snmpwalk -v2c -c public <target> FDRY-POE-MIB::snAgentPoePortConsumed
Get a specific instance (index 1):
snmpget -v2c -c public <target> 1.3.6.1.4.1.1991.1.1.2.14.2.2.1.6.1 snmpget -v2c -c public <target> FDRY-POE-MIB::snAgentPoePortConsumed.1
SNMPv3 example:
snmpget -v3 -l authPriv -u snmpv3-user -a SHA -A "AuthPassword1" -x AES -X "PrivPassword1" <target> snAgentPoePortConsumed.1
Start monitoring Brocade/Foundry FastIron PoE switch (power budget/port monitoring) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the FDRY-POE-MIB::snAgentPoePortConsumed OID value, configure state conditions and alerts, and monitor any Brocade/Foundry FastIron PoE switch (power budget/port monitoring) from a single console.
OID Breakdown
Upper-level ancestors (10 from the standard OID tree / other modules)
| Numeric OID | Name | Module |
|---|---|---|
| 1 | iso | LANART-AGENT |
| 1.3 | org | AirPair-MIB |
| 1.3.6 | dod | AirPair-MIB |
| 1.3.6.1 | internet | AirPair-MIB |
| 1.3.6.1.4 | private | AirPair-MIB |
| 1.3.6.1.4.1 | enterprises | AirPair-MIB |
| 1.3.6.1.4.1.1991 | foundry | FOUNDRY-SN-ROOT-MIB |
| 1.3.6.1.4.1.1991.1 | products | FOUNDRY-SN-ROOT-MIB |
| 1.3.6.1.4.1.1991.1.1 | switch | FOUNDRY-SN-ROOT-MIB |
| 1.3.6.1.4.1.1991.1.1.2 | snAgentSys | FOUNDRY-SN-ROOT-MIB |
| Numeric OID | Name | Module |
|---|---|---|
| 1.3.6.1.4.1.1991.1.1.2.14 | snAgentPoe | FDRY-POE-MIB |
| 1.3.6.1.4.1.1991.1.1.2.14.2 | snAgentPoePort | FDRY-POE-MIB |
| 1.3.6.1.4.1.1991.1.1.2.14.2.2 | snAgentPoePortTable | FDRY-POE-MIB |
| 1.3.6.1.4.1.1991.1.1.2.14.2.2.1 | snAgentPoePortEntry | FDRY-POE-MIB |
| 1.3.6.1.4.1.1991.1.1.2.14.2.2.1.6 | snAgentPoePortConsumed | FDRY-POE-MIB |