ExaltComProducts :: locCurrentTemp

MIB Reference — IPNetwork Monitor · Updated September 14, 2026

All MIBsExaltComProductslocCurrentTemp

locCurrentTemp

Module: ExaltComProducts

OID (symbolic): ExaltComProducts::locCurrentTemp

OID (numeric): 1.3.6.1.4.1.25651.1.2.4.2.3.1.3

Node type: OBJECT-TYPE

Type: Integer32

Access: read-only

Description: The Internal Temperature in Celsius.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.25651.1.2.4.2.3.1.3
snmpwalk -v2c -c public <target> ExaltComProducts::locCurrentTemp

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.25651.1.2.4.2.3.1.3.1
snmpget -v2c -c public <target> ExaltComProducts::locCurrentTemp.1

Start monitoring Exalt Communications microwave backhaul radio (product ID registry) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the ExaltComProducts::locCurrentTemp OID value, configure state conditions and alerts, and monitor any Exalt Communications microwave backhaul radio (product ID registry) from a single console.

How to Use in IPNetwork Monitor

Select an Exalt Communications microwave backhaul radio as the target host to create a monitor — the SNMP service should be up and running on it. Click New Monitor, then check SNMP Custom on the Favorites tab, click Next, and confirm the host. On the next page, click Select... to open the built-in SNMP MIB Browser and type locCurrentTemp into the Find box to locate it in the OID tree, then select it and click OK. It reports the radio's internal temperature, in degrees Celsius. On the monitor's Main parameters page you can set the target's SNMP port (default 161), credentials, polling interval, and other settings — see the SNMP Monitor help for details. On the State conditions and Alerting tabs, configure when the monitor should change state and trigger an alert; since this is an Integer32-type OID, Value bounds is the most useful condition here — trigger an alert if the reported value exceeds 60°C, since sustained high internal temperature often precedes performance degradation or hardware failure. Click Finish to create the monitor; you can adjust any parameter later.

OID Breakdown

Upper-level ancestors (7 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.25651exaltcommunicationsExaltComm
Numeric OIDNameModule
1.3.6.1.4.1.25651.1productsMIBExaltComProducts
1.3.6.1.4.1.25651.1.2productsMIBObjectsExaltComProducts
1.3.6.1.4.1.25651.1.2.4radioMonitorExaltComProducts
1.3.6.1.4.1.25651.1.2.4.2alarmsExaltComProducts
1.3.6.1.4.1.25651.1.2.4.2.3almLocalExaltComProducts
1.3.6.1.4.1.25651.1.2.4.2.3.1locSysAlarmsExaltComProducts
1.3.6.1.4.1.25651.1.2.4.2.3.1.3locCurrentTempExaltComProducts