EdgeSwitch-SNTP-CLIENT-MIB :: agentSntpClientUnicastPollInterval

MIB Reference — IPNetwork Monitor · Updated October 05, 2026

All MIBs › EdgeSwitch-SNTP-CLIENT-MIB › agentSntpClientUnicastPollInterval

agentSntpClientUnicastPollInterval

Module: EdgeSwitch-SNTP-CLIENT-MIB

OID (symbolic): EdgeSwitch-SNTP-CLIENT-MIB::agentSntpClientUnicastPollInterval

OID (numeric): 1.3.6.1.4.1.4413.1.1.17.1.2.1

Node type: OBJECT-TYPE

Type: Unsigned32

Access: read-write

Description: The minimum number of seconds between successive SNTP polls of the server in seconds as a power of two. This polling interval is used for SNTP requests in unicast(1) administrative mode.

What is agentSntpClientUnicastPollInterval?

How many seconds (expressed as a power of two, 6-10) the client waits between unicast SNTP polls to each configured server. Shortening it tightens clock accuracy at the cost of more query traffic; the default of 64 seconds (2^6) is usually fine for switch management clocks.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.4413.1.1.17.1.2.1
snmpwalk -v2c -c public <target> EdgeSwitch-SNTP-CLIENT-MIB::agentSntpClientUnicastPollInterval

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.4413.1.1.17.1.2.1.1
snmpget -v2c -c public <target> EdgeSwitch-SNTP-CLIENT-MIB::agentSntpClientUnicastPollInterval.1

Set instance 1 (SNMPv2c):

snmpset -v2c -c private <target> 1.3.6.1.4.1.4413.1.1.17.1.2.1.1 i <value>

Start monitoring Ubiquiti EdgeSwitch (Broadcom FastPath-based) switch (SNTP time synchronization) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the EdgeSwitch-SNTP-CLIENT-MIB::agentSntpClientUnicastPollInterval OID value, configure state conditions and alerts, and monitor any Ubiquiti EdgeSwitch (Broadcom FastPath-based) switch (SNTP time synchronization) from a single console.

OID Breakdown

Upper-level ancestors (9 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.4413broadcomBASP-Config-MIB
1.3.6.1.4.1.4413.1enetBASP-Config-MIB
1.3.6.1.4.1.4413.1.1fastPathEdgeSwitch-REF-MIB
Numeric OIDNameModule
1.3.6.1.4.1.4413.1.1.17agentSntpClientMIBEdgeSwitch-SNTP-CLIENT-MIB
1.3.6.1.4.1.4413.1.1.17.1agentSntpClientObjectsEdgeSwitch-SNTP-CLIENT-MIB
1.3.6.1.4.1.4413.1.1.17.1.2agentSntpClientUnicastEdgeSwitch-SNTP-CLIENT-MIB
1.3.6.1.4.1.4413.1.1.17.1.2.1agentSntpClientUnicastPollIntervalEdgeSwitch-SNTP-CLIENT-MIB