EdgeSwitch-NSF-MIB :: agentCheckpointMessages

MIB Reference — IPNetwork Monitor · Updated October 05, 2026

All MIBs › EdgeSwitch-NSF-MIB › agentCheckpointMessages

agentCheckpointMessages

Module: EdgeSwitch-NSF-MIB

OID (symbolic): EdgeSwitch-NSF-MIB::agentCheckpointMessages

OID (numeric): 1.3.6.1.4.1.4413.1.1.46.3.2

Node type: OBJECT-TYPE

Type: Counter32

Access: read-only

Description: Total number of checkpoint messages sent.

What is agentCheckpointMessages?

A running counter of the total number of NSF checkpoint messages sent from the active to the standby management unit. Compare its growth rate against agentCheckpointMessageRate to gauge overall checkpoint traffic volume.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.4413.1.1.46.3.2
snmpwalk -v2c -c public <target> EdgeSwitch-NSF-MIB::agentCheckpointMessages

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.4413.1.1.46.3.2.1
snmpget -v2c -c public <target> EdgeSwitch-NSF-MIB::agentCheckpointMessages.1

Start monitoring Ubiquiti EdgeSwitch, Broadcom FastPath-based stackable switch (Non-Stop Forwarding) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the EdgeSwitch-NSF-MIB::agentCheckpointMessages OID value, configure state conditions and alerts, and monitor any Ubiquiti EdgeSwitch, Broadcom FastPath-based stackable switch (Non-Stop Forwarding) from a single console.

How to Use in IPNetwork Monitor

Select an Ubiquiti EdgeSwitch, Broadcom FastPath-based stackable switch (Non-Stop Forwarding) as the target host to create a monitor — the SNMP service should be up and running on it. Click New Monitor, then check SNMP Custom on the Favorites tab, click Next, and confirm the host. On the next page, click Select... to open the built-in SNMP MIB Browser and type agentCheckpointMessages into the Find box to locate it in the OID tree, then select it and click OK. It reports the total number of checkpoint messages sent. On the monitor's Main parameters page you can set the target's SNMP port (default 161), credentials, polling interval, and other settings — see the SNMP Monitor help for details. On the State conditions and Alerting tabs, configure when the monitor should change state and trigger an alert; since this is a Counter32-type OID, Value bounds is the most useful condition here — trigger an alert if the counter increases sharply between polls relative to its normal baseline, since an unexpected spike often reflects a real change in traffic or activity. Click Finish to create the monitor; you can adjust any parameter later.

OID Breakdown

Upper-level ancestors (9 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.4413broadcomBASP-Config-MIB
1.3.6.1.4.1.4413.1enetBASP-Config-MIB
1.3.6.1.4.1.4413.1.1fastPathEdgeSwitch-REF-MIB
Numeric OIDNameModule
1.3.6.1.4.1.4413.1.1.46fastPathNsfEdgeSwitch-NSF-MIB
1.3.6.1.4.1.4413.1.1.46.3agentCheckpointStatsGroupEdgeSwitch-NSF-MIB
1.3.6.1.4.1.4413.1.1.46.3.2agentCheckpointMessagesEdgeSwitch-NSF-MIB