| OID symbolic | OID numeric | Type | Access | Description |
| exinda | 1.3.6.1.4.1.21091 | | | Exinda Networks Vendor MIB |
| system | 1.3.6.1.4.1.21091.1 | | | |
| systemInfo | 1.3.6.1.4.1.21091.1.1 | | | |
| OCT hardwareSeries | 1.3.6.1.4.1.21091.1.1.1 | OCTET STRING | read-only | Hardware series |
| OCT licensedModel | 1.3.6.1.4.1.21091.1.1.2 | OCTET STRING | read-only | Licensed model |
| OCT systemVersion | 1.3.6.1.4.1.21091.1.1.3 | OCTET STRING | read-only | System ExOS version |
| OCT systemHostId | 1.3.6.1.4.1.21091.1.1.4 | OCTET STRING | read-only | System Host ID |
| TIK systemUptime | 1.3.6.1.4.1.21091.1.1.5 | TimeTicks | read-only | System uptime in milliseconds |
| OCT configName | 1.3.6.1.4.1.21091.1.1.6 | OCTET STRING | read-only | Current configuration database name |
| I32 configUnsavedChanges | 1.3.6.1.4.1.21091.1.1.7 | Integer32 | read-only | Unsaved configuration changes {Unsaved(1), Saved(2)} |
| OCT systemTimeZone | 1.3.6.1.4.1.21091.1.1.8 | OCTET STRING | read-only | System timezone |
| cpu | 1.3.6.1.4.1.21091.1.2 | | | |
| U32 cpuLoad1 | 1.3.6.1.4.1.21091.1.2.1 | Unsigned32 | read-only | One-minute CPU load in hundreths |
| U32 cpuLoad5 | 1.3.6.1.4.1.21091.1.2.2 | Unsigned32 | read-only | Five-minute CPU load in hundreths |
| U32 cpuLoad15 | 1.3.6.1.4.1.21091.1.2.3 | Unsigned32 | read-only | Fifteen-minute CPU load in hundreths |
| U32 cpuUsagePercent | 1.3.6.1.4.1.21091.1.2.4 | Unsigned32 | read-only | Percentage CPU utilization for all CPUs over the past minute |
| U32 cpuTemperature | 1.3.6.1.4.1.21091.1.2.5 | Unsigned32 | read-only | Current CPU temperature |
| ram | 1.3.6.1.4.1.21091.1.3 | | | |
| U32 totalRam | 1.3.6.1.4.1.21091.1.3.1 | Unsigned32 | read-only | Total physical system RAM in kbytes |
| U32 usedRam | 1.3.6.1.4.1.21091.1.3.2 | Unsigned32 | read-only | Used physical system RAM in kbytes |
| U32 freeRam | 1.3.6.1.4.1.21091.1.3.3 | Unsigned32 | read-only | Free physical system RAM in kbytes |
| systemHealth | 1.3.6.1.4.1.21091.1.4 | | | |
| OCT cpuAlarm | 1.3.6.1.4.1.21091.1.4.1 | OCTET STRING | read-only | High CPU utilization |
| OCT ramAlarm | 1.3.6.1.4.1.21091.1.4.2 | OCTET STRING | read-only | High swap utilization |
| OCT diskAlarm | 1.3.6.1.4.1.21091.1.4.3 | OCTET STRING | read-only | Full (or almost full) disk partition |
| OCT nicAlarm | 1.3.6.1.4.1.21091.1.4.4 | OCTET STRING | read-only | High collision rate on NICs |
| license | 1.3.6.1.4.1.21091.1.5 | | | |
| INT licensed | 1.3.6.1.4.1.21091.1.5.1 | INTEGER | read-only | System licensed |
| OCT ssExpiry | 1.3.6.1.4.1.21091.1.5.2 | OCTET STRING | read-only | Expiry date for software subscription |
| U32 maxBandwidth | 1.3.6.1.4.1.21091.1.5.3 | Unsigned32 | read-only | Licensed maximum bandwidth |
| U32 maxConnections | 1.3.6.1.4.1.21091.1.5.4 | Unsigned32 | read-only | Licensed maximum connections |
| U32 maxConnectionRate | 1.3.6.1.4.1.21091.1.5.5 | Unsigned32 | read-only | Licensed maximum connection rate |
| U32 maxAccelerationBandwidth | 1.3.6.1.4.1.21091.1.5.6 | Unsigned32 | read-only | Licensed bandwidth for acceleration |
| U32 maxAccelerationConnections | 1.3.6.1.4.1.21091.1.5.7 | Unsigned32 | read-only | Licensed connections for acceleration |
| OCT hardwareAssistedL7 | 1.3.6.1.4.1.21091.1.5.8 | OCTET STRING | read-only | Licenced for fast L7 inspection (monitoring) (Deprecated) |
| OCT optimizerLicensedDepr | 1.3.6.1.4.1.21091.1.5.9 | OCTET STRING | read-only | Licenced for optimizer (Deprecated) |
| U32 maxOptimizerPolicies | 1.3.6.1.4.1.21091.1.5.10 | Unsigned32 | read-only | Licensed maximum number of optimizer policies |
| U32 maxApsObjects | 1.3.6.1.4.1.21091.1.5.11 | Unsigned32 | read-only | Licensed maximum number of APS monitoring objects |
| U32 maxSlaObjects | 1.3.6.1.4.1.21091.1.5.12 | Unsigned32 | read-only | Licensed maximum number of SLA monitoring objects |
| U32 maxPdfReports | 1.3.6.1.4.1.21091.1.5.13 | Unsigned32 | read-only | Licensed maximum number of PDF Reports |
| U32 sslAccelerationLicensedDepr | 1.3.6.1.4.1.21091.1.5.14 | Unsigned32 | read-only | Licensed for SSL Acceleration (Deprecated) |
| OCT virtualizationLicensedDepr | 1.3.6.1.4.1.21091.1.5.15 | OCTET STRING | read-only | Licensed for Virtualization (Deprecated) |
| OCT webCacheLicensedDepr | 1.3.6.1.4.1.21091.1.5.16 | OCTET STRING | read-only | Licensed Web Caching (Deprecated) |
| U32 maxApmObjects | 1.3.6.1.4.1.21091.1.5.17 | Unsigned32 | read-only | Licensed maximum number of APM monitoring objects |
| INT sslAccelerationLicensed | 1.3.6.1.4.1.21091.1.5.18 | INTEGER | read-only | Licensed for SSL Acceleration |
| INT virtualizationLicensed | 1.3.6.1.4.1.21091.1.5.19 | INTEGER | read-only | Licensed for Virtualization |
| INT webCacheLicensed | 1.3.6.1.4.1.21091.1.5.20 | INTEGER | read-only | Licensed Web Caching |
| INT optimizerLicensed | 1.3.6.1.4.1.21091.1.5.21 | INTEGER | read-only | Licenced for optimizer |
| U32 maxNumOfEdgeCacheConnection | 1.3.6.1.4.1.21091.1.5.22 | Unsigned32 | read-only | Maximum numver of Edge-cache connection |
| processes | 1.3.6.1.4.1.21091.1.6 | | | |
| procTable | 1.3.6.1.4.1.21091.1.6.1 | | not-accessible | List of processes managed or monitored by PM |
| procEntry | 1.3.6.1.4.1.21091.1.6.1.1 | | not-accessible | Entry for one process |
| U32 procIndex | 1.3.6.1.4.1.21091.1.6.1.1.1 | Unsigned32 | read-only | Synthetic numeric unique ID of process |
| OCT procName | 1.3.6.1.4.1.21091.1.6.1.1.2 | OCTET STRING | read-only | Unique name of process |
| OCT procStatus | 1.3.6.1.4.1.21091.1.6.1.1.3 | OCTET STRING | read-only | Current state of process |
| U32 procNumFailures | 1.3.6.1.4.1.21091.1.6.1.1.4 | Unsigned32 | read-only | Number of times process has crashed or exited unexpectedly |
| monitor | 1.3.6.1.4.1.21091.2 | | | |
| I32 collectorStatus | 1.3.6.1.4.1.21091.2.1 | Integer32 | read-only | Collector state code {Unknown(0), OK(1), Starting(2), Stopping(3), Error(4)} |
| optimizer | 1.3.6.1.4.1.21091.3 | | | |
| U32 optimizerState | 1.3.6.1.4.1.21091.3.1 | Unsigned32 | read-only | Optimizer state code |
| T/F optimizerRestartRequired | 1.3.6.1.4.1.21091.3.2 | TruthValue | read-only | Optimizer restart required for changes to take affect |
| optimizerTable | 1.3.6.1.4.1.21091.3.3 | | not-accessible | List of optimizer policies |
| optimizerEntry | 1.3.6.1.4.1.21091.3.3.1 | | not-accessible | Entry for one optimizer policy |
| U32 optimizerIndex | 1.3.6.1.4.1.21091.3.3.1.1 | Unsigned32 | read-only | Synthetic numeric unique ID of optimizer policy |
| OCT optimizerId | 1.3.6.1.4.1.21091.3.3.1.2 | OCTET STRING | read-only | ID of optimizer policy |
| OCT optimizerCircuit | 1.3.6.1.4.1.21091.3.3.1.3 | OCTET STRING | read-only | Circuit name of optimizer policy |
| OCT optimizerVcircuit | 1.3.6.1.4.1.21091.3.3.1.4 | OCTET STRING | read-only | Virtual Circuit name of optimizer policy |
| OCT optimizerPolicy | 1.3.6.1.4.1.21091.3.3.1.5 | OCTET STRING | read-only | Policy name |
| OCT optimizerDirection | 1.3.6.1.4.1.21091.3.3.1.6 | OCTET STRING | read-only | Direction of optimizer policy |
| U32 optimizerGuaranteedBandwidth | 1.3.6.1.4.1.21091.3.3.1.7 | Unsigned32 | read-only | Guaranteed rate (kbps) through optimizer policy |
| U32 optimizerMaximumBandwidth | 1.3.6.1.4.1.21091.3.3.1.8 | Unsigned32 | read-only | Maximum rate (kbps) allowed through optimizer policy |
| U32 optimizerCurrentRate | 1.3.6.1.4.1.21091.3.3.1.9 | Unsigned32 | read-only | Current rate (kbps) through optimizer policy |
| C64 optimizerOctets | 1.3.6.1.4.1.21091.3.3.1.10 | Counter64 | read-only | Octets transferred through optimizer policy |
| OCT optimizerBytes | 1.3.6.1.4.1.21091.3.3.1.11 | OCTET STRING | read-only | Bytes transferred through optimizer policy |
| acceleration | 1.3.6.1.4.1.21091.4 | | | |
| tcpAcceleration | 1.3.6.1.4.1.21091.4.2 | | | |
| OCT tcpaCongestionControl | 1.3.6.1.4.1.21091.4.2.1 | OCTET STRING | read-only | TCPA congestion control |
| OCT tcpaTransportMode | 1.3.6.1.4.1.21091.4.2.2 | OCTET STRING | read-only | TCPA transport mode |
| U32 tcpaConnectionsCurrent | 1.3.6.1.4.1.21091.4.2.5 | Unsigned32 | read-only | The number of concurrent connections being accelerated |
| U32 tcpaConnectionsPeak | 1.3.6.1.4.1.21091.4.2.7 | Unsigned32 | read-only | The maximum number of concurrent connections being accelerated at any one time |
| U32 tcpaConnectionsNew | 1.3.6.1.4.1.21091.4.2.9 | Unsigned32 | read-only | The average new accelerated connections per second |
| T/F tcpaDiscovery | 1.3.6.1.4.1.21091.4.2.10 | TruthValue | read-only | Appliance discovery is enabled |
| IP tcpaDiscoveryAddr | 1.3.6.1.4.1.21091.4.2.11 | IpAddress | read-only | Override the IP address that is used for appliance discovery |
| T/F tcpaDualBridgeBypass | 1.3.6.1.4.1.21091.4.2.12 | TruthValue | read-only | Dual bridge acceleration bypass is enabled |
| U32 tcpaWindowScale | 1.3.6.1.4.1.21091.4.2.13 | Unsigned32 | read-only | The TCP window scaling factor |
| wanMemory | 1.3.6.1.4.1.21091.4.3 | | | |
| T/F wmCompression | 1.3.6.1.4.1.21091.4.3.1 | TruthValue | read-only | WAN Memory compression enabled |
| T/F wmSmallMatcher | 1.3.6.1.4.1.21091.4.3.2 | TruthValue | read-only | WAN Memory small matching enabled |
| T/F wmPersistence | 1.3.6.1.4.1.21091.4.3.3 | TruthValue | read-only | WAN Memory persistence enabled |
| C64 wmDiskSize | 1.3.6.1.4.1.21091.4.3.4 | Counter64 | read-only | WAN Memory total disk storage (bytes) |
| C64 wmDiskUsed | 1.3.6.1.4.1.21091.4.3.5 | Counter64 | read-only | WAN Memory disk storage used (bytes) |
| OCT wmDiskUsedPercent | 1.3.6.1.4.1.21091.4.3.6 | OCTET STRING | read-only | WAN Memory disk storage used (percent) |
| C64 wmSendBytesIn | 1.3.6.1.4.1.21091.4.3.7 | Counter64 | read-only | WAN Memory TX bytes in |
| C64 wmSendBytesOut | 1.3.6.1.4.1.21091.4.3.8 | Counter64 | read-only | WAN Memory TX bytes out |
| OCT wmSendReductionPercent | 1.3.6.1.4.1.21091.4.3.9 | OCTET STRING | read-only | WAN Memory TX reduction percentage |
| C64 wmReceiveBytesIn | 1.3.6.1.4.1.21091.4.3.10 | Counter64 | read-only | WAN Memory RX bytes in |
| C64 wmReceiveBytesOut | 1.3.6.1.4.1.21091.4.3.11 | Counter64 | read-only | WAN Memory RX bytes out |
| OCT wmReceiveReductionPercent | 1.3.6.1.4.1.21091.4.3.12 | OCTET STRING | read-only | WAN Memory RX reduction percentage |
| wmTable | 1.3.6.1.4.1.21091.4.3.13 | | not-accessible | List of WAN Memory peers |
| wmPeerEntry | 1.3.6.1.4.1.21091.4.3.13.1 | | not-accessible | Entry for one WAN Memory peer |
| wmPeerEntryNew | 1.3.6.1.4.1.21091.4.3.13.1 | | not-accessible | Entry for one WAN Memory peer |
| U32 wmPeerIndex | 1.3.6.1.4.1.21091.4.3.13.1.1 | Unsigned32 | read-only | Synthetic numeric unique ID of WAN Memory peer |
| U32 wmPeerIndexNew | 1.3.6.1.4.1.21091.4.3.13.1.1 | Unsigned32 | read-only | Synthetic numeric unique ID of WAN Memory peer |
| OCT wmPeerEntryNewWmPeerHostId | 1.3.6.1.4.1.21091.4.3.13.1.2 | OCTET STRING | read-only | Host ID of WAN Memory peer |
| OCT wmPeerHostId | 1.3.6.1.4.1.21091.4.3.13.1.2 | OCTET STRING | read-only | Host ID of WAN Memory peer |
| IP wmPeerEntryNewWmPeerIp | 1.3.6.1.4.1.21091.4.3.13.1.3 | IpAddress | read-only | IP address of WAN Memory peer |
| IP wmPeerIp | 1.3.6.1.4.1.21091.4.3.13.1.3 | IpAddress | read-only | IP address of WAN Memory peer |
| OCT wmPeerEntryNewWmPeerStatus | 1.3.6.1.4.1.21091.4.3.13.1.4 | OCTET STRING | read-only | Status of WAN Memory peer |
| OCT wmPeerStatus | 1.3.6.1.4.1.21091.4.3.13.1.4 | OCTET STRING | read-only | Status of WAN Memory peer |
| OCT wmPeerDiskStatus | 1.3.6.1.4.1.21091.4.3.13.1.5 | OCTET STRING | read-only | Disk status of WAN Memory peer |
| OCT wmPeerEntryNewWmPeerDiskStatus | 1.3.6.1.4.1.21091.4.3.13.1.5 | OCTET STRING | read-only | Disk status of WAN Memory peer |
| U32 wmPeerConnections | 1.3.6.1.4.1.21091.4.3.13.1.6 | Unsigned32 | read-only | Number of connections through WAN Memory peer |
| U32 wmPeerEntryNewWmPeerConnections | 1.3.6.1.4.1.21091.4.3.13.1.6 | Unsigned32 | read-only | Number of connections through WAN Memory peer |
| OCT wmPeerEntryNewWmPeerSendReductionPercent | 1.3.6.1.4.1.21091.4.3.13.1.7 | OCTET STRING | read-only | TX reduction percentage for WAN Memory peer |
| OCT wmPeerSendReductionPercent | 1.3.6.1.4.1.21091.4.3.13.1.7 | OCTET STRING | read-only | TX reduction percentage for WAN Memory peer |
| OCT wmPeerEntryNewWmPeerReceiveReductionPercent | 1.3.6.1.4.1.21091.4.3.13.1.8 | OCTET STRING | read-only | RX reduction percentage for WAN Memory peer |
| OCT wmPeerReceiveReductionPercent | 1.3.6.1.4.1.21091.4.3.13.1.8 | OCTET STRING | read-only | RX reduction percentage for WAN Memory peer |
| cifsAcceleration | 1.3.6.1.4.1.21091.4.4 | | | |
| T/F cifsEnabled | 1.3.6.1.4.1.21091.4.4.1 | TruthValue | read-only | CIFS acceleration enabled |
| T/F cifsReadAhead | 1.3.6.1.4.1.21091.4.4.2 | TruthValue | read-only | CIFS read-ahead acceleration read-ahead enabled |
| T/F cifsWriteAhead | 1.3.6.1.4.1.21091.4.4.3 | TruthValue | read-only | CIFS write-ahead acceleration read-ahead enabled |
| T/F cifsTransactionAcceleration | 1.3.6.1.4.1.21091.4.4.4 | TruthValue | read-only | CIFS transaction acceleration enabled |
| U32 cifsConcurrentConnections | 1.3.6.1.4.1.21091.4.4.5 | Unsigned32 | read-only | Current number of CIFS connections |
| U32 cifsConcurrentAcceleratedConnections | 1.3.6.1.4.1.21091.4.4.6 | Unsigned32 | read-only | Current number of CIFS accelerated connections |
| U32 cifsConcurrentSignedConnections | 1.3.6.1.4.1.21091.4.4.7 | Unsigned32 | read-only | Current number of CIFS signed connections |
| wanMemoryNew | 1.3.6.1.4.1.21091.4.5 | | | |
| T/F wanMemoryNewWmCompression | 1.3.6.1.4.1.21091.4.5.1 | TruthValue | read-only | WAN Memory compression enabled |
| T/F wanMemoryNewWmSmallMatcher | 1.3.6.1.4.1.21091.4.5.2 | TruthValue | read-only | WAN Memory small matching enabled |
| T/F wanMemoryNewWmPersistence | 1.3.6.1.4.1.21091.4.5.3 | TruthValue | read-only | WAN Memory persistence enabled |
| OCT wanMemoryNewWmDiskSize | 1.3.6.1.4.1.21091.4.5.4 | OCTET STRING | read-only | WAN Memory total disk storage (bytes) |
| OCT wanMemoryNewWmDiskUsed | 1.3.6.1.4.1.21091.4.5.5 | OCTET STRING | read-only | WAN Memory disk storage used (bytes) |
| OCT wanMemoryNewWmDiskUsedPercent | 1.3.6.1.4.1.21091.4.5.6 | OCTET STRING | read-only | WAN Memory disk storage used (percent) |
| OCT wanMemoryNewWmSendBytesIn | 1.3.6.1.4.1.21091.4.5.7 | OCTET STRING | read-only | WAN Memory TX bytes in |
| OCT wanMemoryNewWmSendBytesOut | 1.3.6.1.4.1.21091.4.5.8 | OCTET STRING | read-only | WAN Memory TX bytes out |
| OCT wanMemoryNewWmSendReductionPercent | 1.3.6.1.4.1.21091.4.5.9 | OCTET STRING | read-only | WAN Memory TX reduction percentage |
| OCT wanMemoryNewWmReceiveBytesIn | 1.3.6.1.4.1.21091.4.5.10 | OCTET STRING | read-only | WAN Memory RX bytes in |
| OCT wanMemoryNewWmReceiveBytesOut | 1.3.6.1.4.1.21091.4.5.11 | OCTET STRING | read-only | WAN Memory RX bytes out |
| OCT wanMemoryNewWmReceiveReductionPercent | 1.3.6.1.4.1.21091.4.5.12 | OCTET STRING | read-only | WAN Memory RX reduction percentage |
| wanMemoryNewWmTable | 1.3.6.1.4.1.21091.4.5.13 | | not-accessible | List of WAN Memory peers |
| smbV1Acceleration | 1.3.6.1.4.1.21091.4.6 | | | |
| T/F smbV1Enabled | 1.3.6.1.4.1.21091.4.6.1 | TruthValue | read-only | SMB v1 acceleration enabled |
| T/F smbV1ReadAHead | 1.3.6.1.4.1.21091.4.6.2 | TruthValue | read-only | SMB v1 Read AHead |
| T/F smbV1WriteBehind | 1.3.6.1.4.1.21091.4.6.3 | TruthValue | read-only | SMB v1 Write Behind |
| T/F smbV1MetaCache | 1.3.6.1.4.1.21091.4.6.4 | TruthValue | read-only | SMB v1 Meta Cache |
| U32 smbV1PrefetchBytes | 1.3.6.1.4.1.21091.4.6.5 | Unsigned32 | read-only | SMB v1 Prefetch number of bytes |
| notifications | 1.3.6.1.4.1.21091.5 | | | |
| notificationPrefix | 1.3.6.1.4.1.21091.5.0 | | | |
| NTF cpuUtilHigh | 1.3.6.1.4.1.21091.5.0.1 | | | CPU utilization has risen too high |
| NTF diskUsage | 1.3.6.1.4.1.21091.5.0.2 | | | Disk space on the system is low |
| NTF memoryPaging | 1.3.6.1.4.1.21091.5.0.3 | | | The system has been paging excessively (thrashing) |
| NTF nicCollisions | 1.3.6.1.4.1.21091.5.0.4 | | | High NIC collision rate |
| NTF nicNegotiation | 1.3.6.1.4.1.21091.5.0.5 | | | Auto negotiation has failed |
| NTF nicDroppedPackets | 1.3.6.1.4.1.21091.5.0.6 | | | NIC dropped packets - RX |
| NTF nicProblemsRx | 1.3.6.1.4.1.21091.5.0.7 | | | NIC errors - RX |
| NTF nicProblemsTx | 1.3.6.1.4.1.21091.5.0.8 | | | NIC errors - TX |
| NTF bridgeLink | 1.3.6.1.4.1.21091.5.0.9 | | | Bridge link has failed |
| NTF systemStartup | 1.3.6.1.4.1.21091.5.0.10 | | | System startup |
| NTF cifsSignedConn | 1.3.6.1.4.1.21091.5.0.11 | | | CIFS Signed Connections |
| NTF acceleratedConnLimit | 1.3.6.1.4.1.21091.5.0.12 | | | Accelerated connection limit reached |
| NTF slaLatencyAlert | 1.3.6.1.4.1.21091.5.0.13 | | | SLA Latency threshold exceeded |
| NTF slaLossAlert | 1.3.6.1.4.1.21091.5.0.14 | | | SLA Packet loss threshold exceeded |
| NTF systemPowerLostRedundancy | 1.3.6.1.4.1.21091.5.0.17 | | | Power supply redundancy lost |
| NTF systemStorageLostRedundancy | 1.3.6.1.4.1.21091.5.0.18 | | | Storage redundancy lost |
| NTF systemBridgeDirection | 1.3.6.1.4.1.21091.5.0.19 | | | Bridge may be connected incorrectly. Check direction. |
| NTF apsAlert | 1.3.6.1.4.1.21091.5.0.20 | | | APS threshold exceeded |
| NTF apmAlert | 1.3.6.1.4.1.21091.5.0.21 | | | APM threshold exceeded |
| NTF licenseExpired | 1.3.6.1.4.1.21091.5.0.22 | | | Appliance license expired |
| NTF invalidAppliance | 1.3.6.1.4.1.21091.5.0.23 | | | Invalid Appliance |
| NTF retryFailure | 1.3.6.1.4.1.21091.5.0.24 | | | Failed to connect Exinda license server |
| NTF asymmetryDetection | 1.3.6.1.4.1.21091.5.0.25 | | | Asymmetric route detected on appliance |