EXCEL2-SWITCH-MIB :: excelSS7CardRedundancyMate

MIB Reference — IPNetwork Monitor · Updated October 05, 2026

All MIBs › EXCEL2-SWITCH-MIB › excelSS7CardRedundancyMate

excelSS7CardRedundancyMate

Module: EXCEL2-SWITCH-MIB

OID (symbolic): EXCEL2-SWITCH-MIB::excelSS7CardRedundancyMate

OID (numeric): 1.3.6.1.4.1.1751.1.67.2.2.2.4.2.2.4.1.1.1.4

Node type: OBJECT-TYPE

Type: INTEGER

Access: read-only

Description: This entry represents the slot number of the SS7 card associated with this card for the purpose of SS7 redundancy. A value of 255 (0xff) indicates that there is no association.

What is excelSS7CardRedundancyMate?

Read-only slot number (0-255) of the SS7 card paired with this one for redundancy purposes, per its own description, with 255 (0xff) meaning no redundant mate is associated; admins use this to know which physical slot to check when this card's redundancy partner needs servicing.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.1751.1.67.2.2.2.4.2.2.4.1.1.1.4
snmpwalk -v2c -c public <target> EXCEL2-SWITCH-MIB::excelSS7CardRedundancyMate

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.1751.1.67.2.2.2.4.2.2.4.1.1.1.4.1
snmpget -v2c -c public <target> EXCEL2-SWITCH-MIB::excelSS7CardRedundancyMate.1

SNMPv3 example:

snmpget -v3 -l authPriv -u snmpv3-user -a SHA -A "AuthPassword1" -x AES -X "PrivPassword1" <target> excelSS7CardRedundancyMate.1

Start monitoring Lucent Excel2 series managed Ethernet switch with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the EXCEL2-SWITCH-MIB::excelSS7CardRedundancyMate OID value, configure state conditions and alerts, and monitor any Lucent Excel2 series managed Ethernet switch from a single console.

OID Breakdown

Upper-level ancestors (12 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.1751lucentACMIB
1.3.6.1.4.1.1751.1productsAGG-TRAP-MIB
1.3.6.1.4.1.1751.1.67excelAGGREGATED-EXT-MIB
1.3.6.1.4.1.1751.1.67.2excel2AGGREGATED-EXT-MIB
1.3.6.1.4.1.1751.1.67.2.2excelSwitchEXCEL-SWITCH-MIB
1.3.6.1.4.1.1751.1.67.2.2.2excelNodesEXCEL-SWITCH-MIB
Numeric OIDNameModule
1.3.6.1.4.1.1751.1.67.2.2.2.4excelNodeEXCEL2-SWITCH-MIB
1.3.6.1.4.1.1751.1.67.2.2.2.4.2excelNodeSoftwareEXCEL2-SWITCH-MIB
1.3.6.1.4.1.1751.1.67.2.2.2.4.2.2excelCommunicationSoftwareEXCEL2-SWITCH-MIB
1.3.6.1.4.1.1751.1.67.2.2.2.4.2.2.4excelSS7EXCEL2-SWITCH-MIB
1.3.6.1.4.1.1751.1.67.2.2.2.4.2.2.4.1excelSS7ConfigEXCEL2-SWITCH-MIB
1.3.6.1.4.1.1751.1.67.2.2.2.4.2.2.4.1.1excelSS7CardTableEXCEL2-SWITCH-MIB
1.3.6.1.4.1.1751.1.67.2.2.2.4.2.2.4.1.1.1excelSS7CardEntryEXCEL2-SWITCH-MIB
1.3.6.1.4.1.1751.1.67.2.2.2.4.2.2.4.1.1.1.4excelSS7CardRedundancyMateEXCEL2-SWITCH-MIB